CoChat

Simplified capillary isoelectric focusing with chemical mobilization for intact protein analysis

Zhu, Guijie, Sun, Liangliang, Dovichi, Norman J. · 2017 · Journal of Separation Science

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Abstract

We report a capillary isoelectric focusing system based on a sequential injection method for simplified chemical mobilization. This system was coupled to an ion trap mass spectrometer with an electrokinetically pumped nanoelectrospray interface. The nanoelectrospray emitter employed an acidic sheath electrolyte. To simplify focusing and mobilization, a plug of ammonium hydroxide was first injected into the capillary, followed by a section of mixed sample and ampholyte. During focusing, the NH 3 H 2 O section worked as catholyte. As focusing progressed, the NH 3 H 2 O section was titrated to lower pH by the acidic sheath electrolyte. Chemical mobilization started automatically once the ammonium hydroxide was consumed by the acidic sheath flow electrolyte, which then acted as the mobilization solution. In this report, the lengths of the NH 3 H 2 O section and sample were optimized. With a 1 m long capillary, a relative short plug of the NH 3 H 2 O section (3 cm) produced both fast migration and reasonable separation resolution. The simplified capillary isoelectric focusing mass spectrometry system produced base peak intensity relative standard deviation of 8.5% and migration time relative standard deviation ≤0.6% for myoglobin and cytochrome C in triplicate runs.

Overview

Integrity signals

Registry

Crossref · 10.1002/jssc.201601051

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 27 references

Research works printed but not linked: 1

  1. 10.1002/(sici)1522-2683(20000401)21:7<1372::aid-elps1372>3.0.co;2-y · DOI · Paper page

Cited by

See all 24

Metadata

Authors
Zhu, G., Sun, L., & Dovichi, N. J.
Affiliations
  • University of Notre Dame (US)
  • Department of Chemistry and Biochemistry University of Notre Dame Notre Dame IN USA
Venue
Journal of Separation Science
Publisher
Wiley
Published
2016-12-30
Volume
40
Issue
4
Pages
948-953
ISSN
  • 1615-9306 (ISSN-L)
  • 1615-9314
OpenAlex
W2560120411
Cited by
23
References
27
Citations by year
2025: 3 · 2024: 3 · 2023: 2 · 2022: 1 · 2021: 3 · 2020: 1 · 2019: 2 · 2018: 5 · 2017: 3
FWCI
1.61
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Separation Science (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institutes of Health (R01GM096767)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
Keywords
capillary isoelectric focusing, sequential injection, nanoelectrospray ionization, ion trap mass spectrometry, protein separation, myoglobin, cytochrome c, electrokinetic pumping
MeSH terms
Electrolytes, Hydrogen-Ion Concentration, Isoelectric Focusing, Myoglobin, Mass Spectrometry, Electrophoresis, Capillary, Cytochromes c

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simplified capillary isoelectric focusing with chemical mobilization for intact protein analysis. https://app.cochat.ai/papers/10.1002/jssc.201601051
The paper
Zhu, G., Sun, L., & Dovichi, N. J. (2017). Simplified capillary isoelectric focusing with chemical mobilization for intact protein analysis. Journal of Separation Science. https://doi.org/10.1002/jssc.201601051

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.