Matrix effects demystified: Strategies for resolving challenges in analytical separations of complex samples
Open accessThe DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
Matrix effects can significantly impede the accuracy, sensitivity, and reliability of separation techniques presenting a formidable challenge to the analytical process. It is crucial to address matrix effects to achieve accurate and precise measurements in complex matrices. The multifaceted nature of matrix effects which can be influenced by factors such as target analyte, sample preparation protocol, composition, and choice of instrument necessitates a pragmatic approach when analyzing complex matrices. This review aims to highlight common challenges associated with matrix effects throughout the entire analytical process with emphasis on gas chromatography‐mass spectrometry, liquid chromatography‐mass spectrometry, and sample preparation techniques. These techniques are susceptible to matrix effects that could lead to ion suppression/enhancement or impact the analyte signal at various stages of the analytical workflow. The assessment, quantification, and mitigation of matrix effects are necessary in developing any analytical method. Strategies can be implemented to reduce or eliminate the matrix effect by changing the type of ionization, improving extraction and clean‐up methods, optimization of chromatography conditions, and corrective calibration methods. While development of an effective strategy to completely mitigate matrix effects remains elusive, an integrated approach that combines sample preparation, analytical extraction, and effective instrumental analysis remains the most promising avenue for identifying and resolving matrix effects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Low cost adsorbents for the removal of organic pollutants from wastewater
Ali, I., Asim, M., & Khan, T. A. (2012) · Journal of Environmental Management · doi:10.1016/j.jenvman.2012.08.028 · Cited by 1,498
Taylor, P. J. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.11.007 · Cited by 1,248
Evolution of dispersive liquid–liquid microextraction method
Rezaee, M., Yamini, Y., & Faraji, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.088 · Cited by 971
Bonfiglio, R., King, R. C., Olah, T. V., & Merkle, K. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990630)13:12<1175::aid-rcm639>3.0.co;2-0 · Cited by 939
Matuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M. (1998) · Analytical Chemistry · doi:10.1021/ac971078+ · Cited by 880
Signal suppression/enhancement in high-performance liquid chromatography tandem mass spectrometry
Gosetti, F., Mazzucco, E., Zampieri, D., & Gennaro, M. C. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.060 · Cited by 680
Banerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
Ferrer, C., Lozano, A., Agüera, A., Girón, A. J., & Fernández-Alba, A. R. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.07.033 · Cited by 485
Evaluation of Two Fast and Easy Methods for Pesticide Residue Analysis in Fatty Food Matrixes
Lehotay, S. J., Maštovská, K., & Yun, S. J. (2005) · Journal of AOAC INTERNATIONAL · doi:10.1093/jaoac/88.2.630 · Cited by 460
Malachová, A., Sulyok, M., Beltrán, E., Berthiller, F., & Krska, R. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.08.037 · Cited by 444
Matrix effects in (ultra)trace analysis of pesticide residues in food and biotic matrices
Hajšlová, J., & Zrostlı́ková, J. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00539-9 · Cited by 441
Effect of eluent on the ionization process in liquid chromatography–mass spectrometry
Kostiainen, R., & Kauppila, T. J. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.08.095 · Cited by 402
Panuwet, P., Hunter, R. E., D'Souza, P. E., Chen, X., Radford, S. A., Cohen, J. R., Marder, M. E., Kartavenka, K., Ryan, P. B., & Barr, D. B. (2016) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2014.980775 · Cited by 394
Rezaee, M., Yamini, Y., Shariati, S., Esrafili, A., & Shamsipur, M. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.12.091 · Cited by 336
A review of recent developments and trends in the QuEChERS sample preparation approach
Rejczak, T., & Tuzimski, T. (2015) · Open Chemistry · doi:10.1515/chem-2015-0109 · Cited by 313
Analytical strategies for identifying drug metabolites
Prakash, C., Shaffer, C. L., & Nedderman, A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20128 · Cited by 302
Cortese, M., Gigliobianco, M. R., Magnoni, F., Censi, R., & Di Martino, P. (2020) · Molecules · doi:10.3390/molecules25133047 · Cited by 280
Boyacı, E., Rodríguez-Lafuente, Á., Goryński, K., Mirnaghi, F. S., Souza-Silva, É. A., Hein, D., & Pawliszyn, J. B. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.12.051 · Cited by 226
Dispersive liquid–liquid microextraction in food analysis. A critical review
Viñas, P., Campillo, N., López-García, I., & Hernández-Córdoba, M. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7344-9 · Cited by 211
Balakrishnan, V. K., Terry, K. A., & Toito, J. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.07.011 · Cited by 206
Zhao, P., Wang, L., Zhou, L., Zhang, F., Kang, S., & Pan, C. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.12.070 · Cited by 196
Tang, S., Qi, T., Ansah, P. D., Nalouzebi Fouemina, J. C., Shen, W., Basheer, C., & Lee, H. K. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.09.016 · Cited by 195
Steiner, D., Krska, R., Malachová, A., Taschl, I., & Sulyok, M. (2020) · Journal of Agricultural and Food Chemistry · doi:10.1021/acs.jafc.9b07706 · Cited by 194
Rundlett, K. L., & Armstrong, D. W. (1996) · Analytical Chemistry · doi:10.1021/ac960472p · Cited by 192
Ion suppression : A major concern in mass spectrometry
Jessome, L. L., & Volmer, D. A. (2006) · NPARC · Cited by 184
Reduction of Signal Suppression Effects in ESI-MS Using a Nanosplitting Device
Gangl, E. T., Annan, M., Spooner, N., & Vouros, P. (2001) · Analytical Chemistry · doi:10.1021/ac010501i · Cited by 182
Theory for electrostatic interaction chromatography of proteins
Staahlberg, J., Joensson, B., & Horvath, C. (1991) · Analytical Chemistry · doi:10.1021/ac00017a036 · Cited by 156
Kasprzyk‐Hordern, B., Dinsdale, R. M., & Guwy, A. J. (2007) · Talanta · doi:10.1016/j.talanta.2007.08.037 · Cited by 152
Current developments of bioanalytical sample preparation techniques in pharmaceuticals
Ingle, R. G., Zeng, S., Jiang, H., & Fang, W. (2022) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2022.03.001 · Cited by 145
Applications of single-drop microextraction in analytical chemistry: A review
Kailasa, S. K., Koduru, J. R., Park, T. J., Singhal, R. K., & Wu, H. (2020) · Trends in Environmental Analytical Chemistry · doi:10.1016/j.teac.2020.e00113 · Cited by 128
Atmospheric pressure photoionization
Syage, J. A., HANOLD, K., LYNN, T., Horner, J. A., & THAKUR, R. (2004) · Journal of Chromatography A · doi:10.1016/s0021-9673(04)01362-7 · Cited by 128
Rutkowska, E., Łozowicka, B., & Kaczyński, P. (2018) · Food Chemistry · doi:10.1016/j.foodchem.2018.11.130 · Cited by 125
Matrix enhancement effect: A blessing or a curse for gas chromatography?—A review
Rahman, M. M., El‐Aty, A. M. A., & Shim, J. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.09.005 · Cited by 121
Analytical chemistry in a drop
Liu, H., & Dasgupta, P. Κ. (1996) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(96)00065-9 · Cited by 118
Kittlaus, S., Schimanke, J., Kempe, G., & Speer, K. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.09.054 · Cited by 112
Liquid phase microextraction for the analysis of trace elements and their speciation
Hu, B., He, M., Chen, B., & Xia, L. (2013) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2013.05.025 · Cited by 103
Wong, J. W., Zhang, K., Tech, K., Hayward, D. G., Makovi, C. M., Krynitsky, A. J., Schenck, F. J., Banerjee, K., Dasgupta, S., & Brown, D. (2010) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf903854n · Cited by 101
Farajzadeh, M. A., Khoshmaram, L., & Nabil, A. A. A. (2014) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2014.03.004 · Cited by 100
Gionfriddo, E., Souza-Silva, É. A., & Pawliszyn, J. B. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01850 · Cited by 94
Self-citationLashgari, M., Singh, V., & Pawliszyn, J. B. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.07.029 · Cited by 92
Matrix effects on solid-phase microextraction of organophosphorus pesticides from water
Valor, I., Moltó, J. C., Apraiz, D., & Font, G. (1997) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)00027-7 · Cited by 88
Godage, N. H., & Gionfriddo, E. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.12.019 · Cited by 88
Self-citationVudathala, D. K., Cummings, M., & Murphy, L. (2010) · Journal of Analytical Toxicology · doi:10.1093/jat/34.5.273 · Cited by 82
Morris, B. D., & Schriner, R. B. (2015) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf505539e · Cited by 78
Ke, Y., Li, B. J., & Zhang, T. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.05.057 · Cited by 77
Li, W., Zhang, Z.-M., Zhang, R., Jiao, H., Sun, A., Shi, X., & Chen, J. (2019) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2019.121241 · Cited by 69
Sorouraddin, S. M., Farajzadeh, M. A., & Okhravi, T. (2017) · Talanta · doi:10.1016/j.talanta.2017.07.065 · Cited by 56
García-Vara, M., Postigo, C., Palma, P., Bleda, M. J., & de Alda, M. L. (2022) · Food Chemistry · doi:10.1016/j.foodchem.2022.132558 · Cited by 55
Chen, Y., Al-Taher, F., Juskelis, R. O., Wong, J. W., Zhang, K., Hayward, D. G., Zweigenbaum, J. A., Stevens, J., & Cappozzo, J. C. (2012) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf301723g · Cited by 54
Bruins, C. H. P., Jeronimus‐Stratingh, C. M., Ensing, K., van Dongen, W. D., & de Jong, G. J. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00959-0 · Cited by 51
Olomukoro, A. A., DeRosa, C., & Gionfriddo, E. (2023) · Analytica Chimica Acta · doi:10.1016/j.aca.2023.341206 · Cited by 41
Self-citationMu, R., Yuan, J., Huang, Y., Meissen, J. K., Mou, S., Liang, M., & Rosenbaum, A. I. (2022) · BioDrugs · doi:10.1007/s40259-022-00518-w · Cited by 38
Baker, T. C., Tymm, F. J. M., & Murch, S. J. (2017) · Neurotoxicity Research · doi:10.1007/s12640-017-9764-3 · Cited by 37
Reyes‐Garcés, N., Boyacı, E., Gómez‐Ríos, G. A., Olkowicz, M., Monnin, C., Bojko, B., Vuckovic, D., & Pawliszyn, J. B. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2020.461862 · Cited by 30
Chitosan patterning on titanium implants
Chirivella, E. G., Pérez‐Feito, R., Ribeiro, C., Ribeiro, S., Correia, D. M., González-Martín, M. L., Manero, J. M., Lanceros-Méndez, S., Ferrer, G. G., & Ribelles, J. L. G. (2017) · Progress in Organic Coatings · doi:10.1016/j.porgcoat.2017.04.027 · Cited by 28
Chan, C., Bolgar, M. S., Dalpathado, D. S., & Lloyd, D. K. (2012) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.6240 · Cited by 26
Matrix Effects in GC–MS Profiling of Common Metabolites after Trimethylsilyl Derivatization
Tarakhovskaya, E., Marcillo, A., Davis, C. A., Milkovska‐Stamenova, S., Hutschenreuther, A., & Birkemeyer, C. (2023) · Molecules · doi:10.3390/molecules28062653 · Cited by 26
Roszkowska, A., Plenis, A., Kowalski, P., Bączek, T., & Olędzka, I. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116609 · Cited by 18
Jaroch, K., Taczyńska, P., Czechowska, M., Bogusiewicz, J., Łuczykowski, K., Burlikowska, K., & Bojko, B. (2021) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2021.03.005 · Cited by 18
Žideková, N., Pršo, K., Brisudová, K., Babálová, L., Bolek, T., Sivák, Š., Kurča, E., Mokrý, J., Samoš, M., Nosáľ, V., et al. (2023) · Journal of Separation Science · doi:10.1002/jssc.202300084 · Cited by 13
Fernandes, V. C., Domingues, V. F., Nunes, M., Matos, R., Kuźniarska‐Biernacka, I., Fernandes, D. M., Guerrero-Ruiz, A. R., Rodríguez-Ramos, I., Freire, C., & Delerue-Matos, C. M. (2023) · Journal of Agricultural and Food Chemistry · doi:10.1021/acs.jafc.2c07873 · Cited by 12
Godage, N. H., Cudjoe, E., Chau, T. Q., & Gionfriddo, E. (2023) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-023-04589-8 · Cited by 9
Self-citationIn vivo analytical techniques facilitated by contemporary materials
Godage, N. H., Olomukoro, A. A., Emmons, R. V., & Gionfriddo, E. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116290 · Cited by 7
Self-citationHu, L., AGBOKPONTO, J. E., Ding, L., Liu, B., Shi, F., & Gong, C. (2014) · Biomedical Chromatography · doi:10.1002/bmc.3239 · Cited by 6
Metadata
- Authors
- Williams, M. L., Olomukoro, A. A., Emmons, R. V., Godage, N. H., & Gionfriddo, E.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2023-10-28
- Volume
- 46
- Issue
- 23
- Pages
- e2300571-e2300571
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W4388001180
- Cited by
- 247
- References
- 65
- FWCI
- 30.12
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.