Artificial neural network classification of pharyngeal high‐resolution manometry with impedance data
Open accessAbstract
Objectives/Hypothesis: To use classification algorithms to classify swallows as safe, penetration, or aspiration based on measurements obtained from pharyngeal high‐resolution manometry (HRM) with impedance. Study Design: Case series evaluating new method of data analysis. Methods: Multilayer perceptron, an artificial neural network (ANN), was evaluated for its ability to classify swallows as safe, penetration, or aspiration. Data were collected from 25 disordered subjects swallowing 5‐ or 10‐mL boluses. Following extraction of relevant parameters, a subset of the data was used to train the models, and the remaining swallows were then independently classified by the ANN. Results: A classification accuracy of 89.4 ± 2.4% was achieved when including all parameters. Including only manometry‐related parameters yielded a classification accuracy of 85.0 ± 6.0%, whereas including only impedance‐related parameters yielded a classification accuracy of 76.0 ± 4.9%. Receiver operating characteristic analysis yielded areas under the curve of 0.8912 for safe, 0.8187 for aspiration, and 0.8014 for penetration. Conclusions: Classification models show high accuracy in classifying swallows from dysphagic patients as safe or unsafe. HRM‐impedance with ANN represents one method that could be used clinically to screen for patients at risk for penetration or aspiration. Laryngoscope, 2013
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
0 of 23 cited sources checked · 0 supported · 0 flagged
- Findingreasoning
Modifying the ANN architecture, such as increasing the number of hidden nodes, had a minimal effect on classification accuracy.
“Our efforts to improve performance by modifying the architecture of the ANN, such as increasing the number of hidden nodes, had a minimal effect on classification accuracy (table 4).”
Quote in the paperNot a substantial claim - Findingown data
Maximum velopharynx pressure achieved the highest individual classification accuracy at 38.6%.
“Maximum velopharynx pressure achieved the highest classification accuracy at 38.6%.”
- Also stated in: § DISCUSSION · plain
“Maximum velopharyngeal pressure (38.6%), velopharyngeal pressure integral (36.3%), and post-closure UES rise time (33.1%) provided the highest classification accuracies.”
Quote in the paperNot a substantial claim - Also stated in: § DISCUSSION · plain
- Findingown data
No single parameter was able to classify swallows as penetration or aspiration with high accuracy.
“More interestingly, no single parameter was able to classify swallows as penetration or aspiration with high accuracy.”
Quote in the paperSubstantial claim - Findingown data
For aspiration, combining all parameters yielded a classification accuracy of 82.5%.
“combining all parameters led to significantly higher classification rates of 65.9% for penetration and 82.5% for aspiration.”
Quote in the paperSubstantial claim - Findingown data
ROC analysis yielded an area under the curve of 0.8912 for safe swallows.
“Receiver operating characteristic (ROC) analysis yielded areas under the curve (AUC) of 0.8912 for safe, 0.8187 for aspiration, and 0.8014 for penetration.”
- Also stated in: § Artificial neural network classification · plain
“ROC analysis yielded curves with AUC of 0.8912 for safe (figure 2a), 0.8187 for aspiration (figure 2b), and 0.8014 for penetration (figure 2c).”
Quote in the paperSubstantial claim - Also stated in: § Artificial neural network classification · plain
- Findingown data
The majority of unsafe swallows were on a liquid bolus (38 of 49).
“As the majority of unsafe swallows were on a liquid bolus (thirty-eight of forty-nine)”
Quote in the paperSubstantial claim - Findingreasoning
Bolus characteristics did not appear to negatively affect classification accuracy in this experiment.
“Bolus characteristics did not appear to negatively affect classification accuracy in this experiment”
Quote in the paperSubstantial claim- Rests on an assumption: A main benefit of ANN analysis is that it recognizes patterns rather than trends in single variables.
- Findingown data
When individual parameters were used, overall classification accuracy ranged from 63.8% to 73.6%.
“Percent accuracy ranged from 63.8% to 73.6% (table 3).”
- Also stated in: § DISCUSSION · plain
“Percent classification accuracy ranged from 79.1% to 98.2% for safe swallows and from 63.8% to 73.6% overall.”
Quote in the paperSubstantial claim - Also stated in: § DISCUSSION · plain
- Findingown data
The artificial neural network classified swallows with an accuracy of 89.4±2.4% when all parameters were included.
“A classification accuracy of 89.4±2.4% was achieved when including all parameters.”
- Also stated in: § Artificial neural network classification · plain
“A classification accuracy of 89.4±2.4% was achieved when including all parameters.”
Quote in the paperSubstantial claim - Also stated in: § Artificial neural network classification · plain
- Findingown data
Individual parameters had low classification rates for penetration and aspiration, ranging from 7.1% to 38.6%.
“Individual parameters had relatively low classification rates for penetration and aspiration, with a range of 7.1% to 38.6% (table 3).”
- Also stated in: § DISCUSSION · plain
“Percent classification accuracy ranged from 7.1% to 38.6%.”
Quote in the paperSubstantial claim - Also stated in: § DISCUSSION · plain
- Findingown data
The artificial neural network classified swallows with an accuracy of 76.0±4.9% when only impedance-related parameters were included.
“Including only manometry-related parameters yielded a classification accuracy of 85.0±6.0% while including only impedance-related parameters yielded a classification accuracy of 76.0±4.9%.”
- Also stated in: § Artificial neural network classification · plain
“Including only manometry-related parameters yielded a classification accuracy of 85.0±6.0% while including only impedance-related parameters yielded a classification accuracy of 76.0±4.9% (table 1).”
Quote in the paperSubstantial claim - Also stated in: § Artificial neural network classification · plain
- Findingown data
The artificial neural network classified swallows with an accuracy of 85.0±6.0% when only manometry-related parameters were included.
“Including only manometry-related parameters yielded a classification accuracy of 85.0±6.0% while including only impedance-related parameters yielded a classification accuracy of 76.0±4.9%.”
- Also stated in: § Artificial neural network classification · plain
“Including only manometry-related parameters yielded a classification accuracy of 85.0±6.0% while including only impedance-related parameters yielded a classification accuracy of 76.0±4.9% (table 1).”
Quote in the paperSubstantial claim - Also stated in: § Artificial neural network classification · plain
- Findingown data
ROC analysis yielded an area under the curve of 0.8014 for penetration.
“Receiver operating characteristic (ROC) analysis yielded areas under the curve (AUC) of 0.8912 for safe, 0.8187 for aspiration, and 0.8014 for penetration.”
- Also stated in: § Artificial neural network classification · plain
“ROC analysis yielded curves with AUC of 0.8912 for safe (figure 2a), 0.8187 for aspiration (figure 2b), and 0.8014 for penetration (figure 2c).”
Quote in the paperSubstantial claim - Also stated in: § Artificial neural network classification · plain
- Findingown data
The three impedance parameters (PNadImp, TPNadImp-PeakP, pharyngeal flow interval) differed significantly or near-significantly across the safe, penetration, and aspiration groups.
“All impedance parameters were significantly or near significantly different across groups (PNadImp: p=0.015; TPNadImp-PeakP: p=0.054; pharyngeal flow interval: p<0.001).”
- Also stated in: § DISCUSSION · plain
“Each of the three impedance parameters (PNadImp, TPNadImp-PeakP, pharyngeal flow interval) was significantly different across categories.”
Quote in the paperNot a substantial claim - Also stated in: § DISCUSSION · plain
- Findingreasoning
There was not a consistent correlation between ANOVA p-values and classification accuracy.
“Most notably, there was not a consistent correlation between p-values resulting from ANOVA and classification accuracy.”
Quote in the paperSubstantial claim - Findingown data
ROC analysis yielded an area under the curve of 0.8187 for aspiration.
“Receiver operating characteristic (ROC) analysis yielded areas under the curve (AUC) of 0.8912 for safe, 0.8187 for aspiration, and 0.8014 for penetration.”
- Also stated in: § Artificial neural network classification · plain
“ROC analysis yielded curves with AUC of 0.8912 for safe (figure 2a), 0.8187 for aspiration (figure 2b), and 0.8014 for penetration (figure 2c).”
Quote in the paperSubstantial claim - Also stated in: § Artificial neural network classification · plain
- Findingown data
Many of the significant manometric parameters were related to the UES.
“Of the manometric parameters demonstrating significant differences, many were related to the UES.”
Quote in the paperNot a substantial claim - Findingreasoning
Classification accuracy was higher for aspiration than for penetration.
“Classification accuracy was higher for aspiration than penetration.”
Quote in the paperNot a substantial claim - Interpretationown data
The low number of unsafe swallows (17 penetration, 32 aspiration) may have contributed to low classification rates.
“Low classification rates could be due to difficulty distinguishing between the two types of unsafe swallows and could also be due to the relatively low number of unsafe swallows (17 penetration, 32 aspiration) included in the analysis.”
Quote in the paperSubstantial claim - Interpretationown data
Differences detected in individual parameters across groups cannot be completely attributed to swallow status.
“differences detected in individual parameters across groups cannot be completely attributed to swallow status (i.e., safe, penetration, or aspiration).”
Quote in the paperSubstantial claim - Interpretationown data
Neither manometric nor impedance parameters alone provided penetration classification accuracy high enough to provide a basis for clinical decision-making.
“Neither rate is high enough to provide a basis for clinical decision-making”
Quote in the paperSubstantial claim - Interpretationreasoning
Including only manometric parameters led to greater classification accuracy than including only impedance parameters.
“Interestingly, including only manometric parameters led to greater classification accuracy than including only impedance parameters.”
Quote in the paperNot a substantial claim - Interpretationown data
The greatest classification accuracy was achieved when combining both pressure and impedance information.
“The greatest classification accuracy, though, was achieved when combining both pressure and impedance information, demonstrating the importance of a comprehensive assessment.”
Quote in the paperSubstantial claim - Interpretationown data
The disparity between individual parameter classification rates and group classification rates demonstrates the importance of multi-parameter assessment.
“This disparity between individual parameter classification rates and group classification rates demonstrates the importance of multi-parameter assessment.”
Quote in the paperSubstantial claim - Premisecitation
Manometric parameters describing UES muscular activity are strong predictors of pharyngeal function.
“Manometric parameters describing the muscular activity in this region are strong predictors of pharyngeal function, as an inability to pass the bolus through the UES due to poorly controlled muscular activity can result in penetration and aspiration of materials retained in the pharynx.26-27”
Quote in the paperSubstantial claim0 of 2 sources checked - Interpretationown data
The pattern recognition techniques employed here appear to be clinically useful in identifying patients at risk for aspiration.
“The pattern recognition techniques employed here appear to be clinically useful in identifying patients at risk for aspiration.”
Quote in the paperNot a substantial claim- Rests on an assumption: Detecting aspiration is critical to the clinical utility of any swallowing evaluation.
- Interpretationreasoning
Individual parameter analyses are more susceptible to identifying differences due to bolus type rather than swallow type.
“Individual parameter analyses are more susceptible to identifying differences due to bolus type rather than swallow type.”
Quote in the paperSubstantial claim - Interpretationown data
The high accuracy in this preliminary study provides evidence that HRM-impedance has potential as an alternative clinical assessment tool, especially when coupled with ANN techniques.
“The high accuracy in this preliminary study provides evidence that HRM-impedance has potential as an alternative clinical assessment tool, especially when coupled with ANN techniques.”
Quote in the paperSubstantial claim- Rests on an assumption: HRM-impedance provides an alternative assessment that avoids radiation, can be done at the bedside, and yields quantitative information on many swallowing-related parameters.
- Interpretationown data
Classification models show high accuracy in classifying swallows from dysphagic patients as safe or unsafe.
“Classification models show high accuracy in classifying swallows from dysphagic patients as safe or unsafe.”
Quote in the paperSubstantial claim - Interpretationown data
Manometric and impedance parameters performed better collectively than either group did individually.
“Manometric and impedance parameters performed better collectively than either group did individually, as demonstrated by the differences in classification rates (table 1).”
Quote in the paperSubstantial claim - Premisecitation
Combining pressure measurement with impedance measurement provides an assessment of both motility and flow of luminal content.
“Combining pressure measurement with impedance measurement provides an assessment of both motility and flow of luminal content.5”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [5] source
Not checked in the free run.
- Interpretationreasoning
HRM-impedance with ANN represents one method which could be used clinically to screen for patients at risk for penetration or aspiration.
“HRM-impedance with ANN represents one method which could be used clinically to screen for patients at risk for penetration or aspiration.”
Quote in the paperSubstantial claim- Rests on an assumption: HRM-impedance provides an alternative assessment that avoids radiation, can be done at the bedside, and yields quantitative information on many swallowing-related parameters.
- Rests on an assumption: Detecting aspiration is critical to the clinical utility of any swallowing evaluation.
- Rests on an assumption: Penetration and aspiration are common in dysphagic patients because of weakness and poorly coordinated swallowing.
- Interpretationreasoning
This provides support for a comprehensive multi-parameter analysis such as that provided by ANN analysis of HRM-impedance, rather than isolated measurements of peak pharyngeal pressure or UES pressure.
“Accordingly, this provides support for a comprehensive multi-parameter analysis such as that provided by ANN analysis of HRM-impedance, rather than isolated measurements of peak pharyngeal pressure or UES pressure, for example.”
Quote in the paperNot a substantial claim - Premisecitation
An inability to pass the bolus through the UES due to poorly controlled muscular activity can result in penetration and aspiration of materials retained in the pharynx.
“Manometric parameters describing the muscular activity in this region are strong predictors of pharyngeal function, as an inability to pass the bolus through the UES due to poorly controlled muscular activity can result in penetration and aspiration of materials retained in the pharynx.26-27”
Quote in the paperNot a substantial claim0 of 2 sources checked - Interpretationreasoning
The low number of penetration swallows (seventeen) may have contributed to the low penetration classification rate.
“The low number of swallows exhibiting penetration included in the analysis (seventeen) may also have contributed to the low classification rate, as introducing fewer examples of one category during the training stage can have an adverse effect during the testing stage.”
Quote in the paperNot a substantial claim - Interpretationreasoning
The relationships among variables, rather than absolute values of each parameter in isolation, appear to be the key in distinguishing safe from unsafe swallows.
“This finding also has physiological significance, as the relationships among the variables of interest, rather than absolute values of each parameter in isolation, appear to be the key in distinguishing safe from unsafe swallows.”
Quote in the paperSubstantial claim
- May combine two claims. 16
- Classified as probably not a substantial claim. 18
May combine two claims.
Findingown dataMost penetration and aspiration events occurred on liquid boluses (6 of 10 penetration, 22 of 29 aspiration).
“The majority of penetration and aspiration events occurred on liquid boluses. Of the ten swallows exhibiting penetration, six were with a liquid bolus, three were with a semisolid bolus, and one was with a solid bolus. Of the twenty-nine swallows exhibiting aspiration, twenty-two were with a liquid bolus, two were with a semisolid bolus, and five were with a solid bolus.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataIn total, 163 swallows were analyzed: 114 safe, 17 penetration, and 32 aspiration.
“In total, 163 swallows were analyzed and the derived feature sets were used as a basis for determining models of safe swallow, penetration, and aspiration. Of the 163 swallows, 114 were safe, 17 exhibited penetration, and 32 exhibited aspiration.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataSeveral manometric parameters differed significantly across the three swallow categories, including UES intrabolus pressure, UES mean relaxation pressure, UES deglutitive sphincter resistance, slope, post-closure UES pressure, velopharyngeal pressure duration, UES duration, total swallow duration, UES pressure integral, peak pharyngeal pressure, maximum velopharyngeal pressure, velopharyngeal压力积分,
“Manometric parameters demonstrating significant differences across groups included UES intrabolus pressure (p<0.001), UES mean relaxation pressure (p<0.001), UES deglutitive sphincter resistance (p=0.001), slope (p=0.008), post-closure UES pressure (p=0.004), velopharyngeal pressure duration (p=0.037), UES duration (p=0.032), total swallow duration (p=0.008), UES pressure integral (p<0.001), peak”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataA greater proportion of impedance parameters were significant (2 of 3) compared to manometric parameters (13 of 28), but classification accuracy was higher when considering only manometric parameters.
“While a greater proportion of impedance parameters were significant (two of three) compared to manometric parameters (thirteen of twenty-eight), classification accuracy was higher when considering only manometric parameters.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataMaximum velopharyngeal pressure (38.6%), velopharyngeal pressure integral (36.3%), and post-closure UES rise time (33.1%) provided the highest individual classification accuracies.
“Maximum velopharyngeal pressure (38.6%), velopharyngeal pressure integral (36.3%), and post-closure UES rise time (33.1%) provided the highest classification accuracies.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataFor penetration, manometric parameters alone yielded 51.2% accuracy, impedance parameters alone yielded 25.9%, and combining both yielded 65.9%.
“Using manometric parameters alone led to a classification accuracy of 51.2% while impedance parameters alone led to a classification accuracy of 25.9%. Neither rate is high enough to provide a basis for clinical decision-making; however, combining manometric and impedance parameters led a classification accuracy of 65.9%.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
InterpretationreasoningAs impedance can detect bolus clearance and poor bolus clearance is more likely to result in penetration or aspiration, significant differences across the three categories can be expected.
“As impedance can detect bolus clearance and poor bolus clearance is more likely to result in penetration or aspiration, significant differences across the three categories can be expected.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S4 (based).
Premisenone givenOne-way ANOVA cannot determine the value of relationships among parameters.
“Also, one-way ANOVA cannot determine the value of relationships among parameters.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
Study design and conductreasoningThe training and testing data were kept separate to better evaluate the generalizing ability of the classification.
“The training and testing data are kept separate to better evaluate the generalizing ability of the classification.”
Quote in the paperSubstantial claimClassified as probably not a substantial claim.
Study design and conductcitationSwallows were analyzed for aspiration and penetration using an 8-point scale described by Rosenbeck et al.
“Swallows were analyzed for aspiration and penetration using an 8-point scale (1: safe; 2-5: penetration; 6-8: aspiration) described by Rosenbeck et al.15”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Rosenbeck et al., 15
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductreasoningMultiple bolus types were included, so statistical testing may reflect differences due to both bolus and swallow characteristics.
“It is important to note that multiple bolus types were included in the analysis; thus, results of statistical testing may reflect differences in individual parameters due to both bolus and swallow characteristics.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S2 (checkable), S3 (load-bearing), S4 (based).
Interpretationown dataThis demonstrates the importance of including a wide range of parameters in the ANN.
“This demonstrates the importance of including a wide range of parameters in the ANN.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationWhile impedance may not reliably measure pharyngeal bolus transit time, it can provide information on the presence or absence of pharyngeal bolus residue.
“While impedance may not reliably measure pharyngeal bolus transit time,5 it can provide information on the presence or absence of pharyngeal bolus residue.7-8”
Quote in the paperSubstantial claim0 of 3 sources checkedProbably not a substantial claim: may not pass S1 (asserted), S3 (load-bearing).
Study design and conductreasoningWhich swallows are used in the training set and testing set changes so all data are used in the test stage at some point.
“Which swallows are used in the training set and testing set changes so all data are used in the test stage at some point.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductnone givenTen replicates were performed at each level of hidden nodes to determine the average classification accuracy and reliability.
“Ten replicates were performed at each level of hidden nodes to determine the average classification accuracy at that level as well as the reliability of that classification.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationreasoningParameters with low individual classification rates do not adversely affect overall classification accuracy because relationships among parameters are more important and any detrimental parameter is weighted minimally.
“It is important to note that parameters with low individual classification rates do not adversely affect overall classification accuracy, as the relationships among parameters are more important and any parameter which would decrease classification ability is weighted such that its effect is minimal.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationANNs have been used to analyze voice and swallow events, differentiating between normal and disordered events, as well as distinguishing among different types of disorders.
“ANNs have been used to analyze voice and swallow events, differentiating between normal and disordered events, as well as distinguishing among different types of disorders.9-12”
Quote in the paperNot a substantial claim0 of 4 sources checkedClassified as probably not a substantial claim.
PremisecitationPattern recognition techniques, including ANNs, are powerful mathematical models that can handle large data sets and classify data into groups according to nonlinear statistical analysis.
“Pattern recognition techniques, including artificial neural networks (ANNs), are powerful mathematical models which can handle large data sets and classify data into groups according to nonlinear statistical analysis.9-11”
Quote in the paperSubstantial claim0 of 3 sources checkedMay combine two claims.
Interpretationown dataThe wide age range (30-95 years) with high average classification accuracy (89.4%) demonstrates the power and generalizability of the algorithm.
“Notably, there was a wide age range included in this study (30 – 95 years). Despite this range, classification accuracy was rather high (average of 89.4%), demonstrating the power and generalizability of the algorithm.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationVideofluoroscopy is traditionally considered the gold standard for evaluating aspiration but requires radiation exposure and is a fairly poor predictor of aspiration pneumonia.
“Videofluoroscopy has traditionally been considered the gold standard for evaluating aspiration, but requires radiation exposure and is a fairly poor predictor of aspiration pneumonia.5,13,14”
Quote in the paperSubstantial claim0 of 3 sources checkedClassified as probably not a substantial claim.
Study design and conductnone givenThe data set was randomly partitioned into a training set (60%), a testing set (20%), and a validation set (20%).
“The data set was randomly partitioned into a training set (60%), a testing set (20%), and a validation set (20%).”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationIntraluminal impedance detects the speed and direction of bolus movement as it progresses through the digestive tract.
“Intraluminal impedance detects the speed and direction of bolus movement as it progresses through the digestive tract.4”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [4] source
Not checked in the free run.
Probably not a substantial claim: may not pass S2 (checkable).
Premisenone givenThe nonlinear capabilities of ANN analysis allow for efficient evaluation and weighting of these relationships.
“The nonlinear capabilities of ANN analysis allow for efficient evaluation and weighting of these relationships.”
Quote in the paperNot a substantial claim- Rests on an assumption: The nonlinear capabilities of ANN analysis allow efficient evaluation and weighting of relationships among parameters.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationAspiration pneumonia is the leading cause of death in Parkinson's disease.
“Aspiration pneumonia is the leading cause of death in Parkinson's disease.20-21”
Quote in the paperNot a substantial claim0 of 2 sources checkedProbably not a substantial claim: may not pass S2 (checkable). May combine two claims.
InterpretationreasoningGiven the large number of parameters included in this study (thirty-two), human data interpretation would be time intensive at best and likely impossible.
“Given the large number of parameters included in this study (thirty-two), human data interpretation would be time intensive at best and likely impossible.”
Quote in the paperNot a substantial claim- Rests on an assumption: Human interpretation of the thirty-two parameters in this study would be time intensive at best and likely impossible.
May combine two claims.
Study design and conductnone givenAll subjects included in the analysis had dysphagia and many had a neurologic etiology.
“All subjects included in the analysis had dysphagia and many had a neurologic etiology of their swallowing disorder.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationNormalizing the data improves algorithm efficiency and accuracy.
“Normalizing the data improves algorithm efficiency and accuracy.19”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [19] source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
InterpretationreasoningThis is likely a consequence of implementing measures to prevent overfitting in large networks.
“This is likely a consequence of implementing measures to prevent overfitting in large networks.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim. May combine two claims.
InterpretationreasoningUtilizing the machine learning techniques of ANNs allows for analysis to be completed and feedback be provided in seconds.
“Utilizing the machine learning techniques of ANNs allows for analysis to be completed and feedback be provided in seconds.”
Quote in the paperSubstantial claim- Rests on an assumption: Using ANN machine learning allows analysis and feedback to be completed in seconds.
The paper relies on this without support.
HRM-impedance provides an alternative assessment that avoids radiation, can be done at the bedside, and yields quantitative information on many swallowing-related parameters.
“HRM-impedance offers an alternative that does not expose subjects to radiation, can be performed at the bedside, and provides quantitative information on a wide range of parameters relevant to swallowing function.”
The paper relies on this without support.
Detecting aspiration is critical to the clinical utility of any swallowing evaluation.
“Critical to the clinical utility of any swallowing evaluation is the ability to detect aspiration, a potentially life-threatening swallowing abnormality that can lead to aspiration pneumonia.”
The paper relies on this without support.
Penetration and aspiration are common in dysphagic patients because of weakness and poorly coordinated swallowing.
“Penetration and aspiration are common in this patient population due to weakness and a poorly coordinated swallow.”
The paper relies on this without support.
Generating pressure gradients is the key to safe swallowing.
“Additionally, generation of pressure gradients is the key to safe swallowing and analysis of pressure may be more reflective of abnormal swallowing than analysis of impedance.”
The paper relies on this without support.
A main benefit of ANN analysis is that it recognizes patterns rather than trends in single variables.
“However, a main benefit of ANN analysis is the ability to recognize patterns rather than trends in single variables.”
The paper relies on this without support.
Human interpretation of the thirty-two parameters in this study would be time intensive at best and likely impossible.
“Given the large number of parameters included in this study (thirty-two), human data interpretation would be time intensive at best and likely impossible.”
The paper relies on this without support.
Using ANN machine learning allows analysis and feedback to be completed in seconds.
“Utilizing the machine learning techniques of ANNs allows for analysis to be completed and feedback be provided in seconds.”
The paper relies on this without support.
The nonlinear capabilities of ANN analysis allow efficient evaluation and weighting of relationships among parameters.
“The nonlinear capabilities of ANN analysis allow for efficient evaluation and weighting of these relationships.”
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
VFSS with high-resolution manometry has been considered in the evaluation of pharyngeal and esophageal anatomical structures.
“VFSS, along with high-resolution manometry, has also been considered in the evaluation of pharyngeal and esophageal anatomical structures(27,29-31)”
From Artificial intelligence in the diagnosis and management of dysphagia: a scoping review (2025) · cites this paper as [29]
The Methods (Data collection; page unavailable) report simultaneous fluoroscopy and high-resolution manometry, with sensors spanning the velopharynx to the proximal esophagus. But the paper describes assessing swallowing pressures, bolus movement, and penetration or aspiration—not evaluating pharyngeal and esophageal anatomical structures as the claim states. (LLM, conf=0.85)
Experimental — accuracy not yet measuredStudies utilizing deep learning and neural network classifiers for esophageal motility have reported sensitivity metrics above 85%.
“studies utilizing deep learning and neural network classifiers for esophageal motility have reported sensitivity metrics above 85%, offering promising diagnostic complements(29,30)”
From Artificial intelligence in the diagnosis and management of dysphagia: a scoping review (2025) · cites this paper as [29]
The Results report 89.4% overall classification accuracy for a neural-network analysis, and the Conclusion describes potential clinical value. But the study classifies pharyngeal swallows, not esophageal motility, and reports accuracy rather than a sensitivity metric above 85%. The Discussion reports classification rates of 82.5% for aspiration and 65.9% for penetration. (LLM, conf=0.88)
Experimental — accuracy not yet measuredStroke-related dysphagia has been widely studied with algorithms like SVMs and deep neural networks demonstrating robust accuracy in predicting aspiration events and laryngeal vestibule closure.
“Stroke-related dysphagia, for example, has been widely studied with algorithms like SVMs and deep neural networks demonstrating robust accuracy in predicting aspiration events and laryngeal vestibule closure(29,32).”
From Artificial intelligence in the diagnosis and management of dysphagia: a scoping review (2025) · cites this paper as [29]
The Materials and Methods (Data collection and Data analysis; page unavailable) include six participants with stroke and describe an artificial neural network trained to classify safe swallows, penetration, and aspiration. The Discussion (page unavailable) reports high classification accuracy, but not stroke-specific accuracy; the paper does not report SVM or deep-neural-network results or prediction of laryngeal vestibule closure. (LLM, conf=0.89)
Experimental — accuracy not yet measuredPenetration-aspiration classification accuracy was 84.2% under a binary scheme, lower than the previously reported 89.4% under a ternary scheme.
“Secondly, the classification accuracy of 84.2% observed for penetration-aspiration was based on a binary classification scheme (normal versus penetration+aspiration) and was lower than our previously reported value of 89.4% obtained using a ternary scheme (normal versus penetration versus aspiration).13”
From Classification of high-resolution manometry data according to videofluoroscopic parameters using pattern recognition (2013) · cites this paper as [13]
The authors previously applied ANNs to classify HRM data into normal and disordered swallows and to identify penetration and aspiration.
“We previously applied ANNs to classify HRM data into normal and disordered swallows12 as well as identify penetration and aspiration.13”
From Classification of high-resolution manometry data according to videofluoroscopic parameters using pattern recognition (2013) · cites this paper as [13]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Aspiration count conflicts between Results and Discussion
MajorThe paper reports 32 aspiration swallows in the data processing section, but later describes 29 aspiration swallows when breaking down bolus types. These two statements cannot both be true for the same analyzed set.
“Of the 163 swallows, 114 were safe, 17 exhibited penetration, and 32 exhibited aspiration.”
“Of the twenty-nine swallows exhibiting aspiration, twenty-two were with a liquid bolus, two were with a semisolid bolus, and five were with a solid bolus.”
Penetration count conflicts between Results and Discussion
MinorThe data processing section says 17 swallows exhibited penetration, but a later discussion passage says there were 10 penetration swallows, with a bolus breakdown that sums to 10. This is an internal inconsistency in the reported sample composition.
“Of the 163 swallows, 114 were safe, 17 exhibited penetration, and 32 exhibited aspiration.”
“Of the ten swallows exhibiting penetration, six were with a liquid bolus, three were with a semisolid bolus, and one was with a solid bolus.”
Significance claim conflicts with the reported impedance result
MinorThe discussion says all three impedance parameters were significant, but elsewhere states that only two of three were significant. The reported p-value of 0.054 for the remaining parameter also exceeds the stated 0.05 threshold.
“Each of the three impedance parameters (PNadImp, TPNadImp-PeakP, pharyngeal flow interval) was significantly different across categories.”
“While a greater proportion of impedance parameters were significant (two of three) compared to manometric parameters (thirteen of twenty-eight), classification accuracy was higher when considering only manometric parameters.”
The citation lists haven’t been fetched yet
References 27 · Cited by 34
- Authors
- Hoffman, M. R., Mielens, J. D., Omari, T. I., Rommel, N., Jiang, J. J., & McCulloch, T. M.
- Affiliations
- University of Wisconsin–Madison (US)
- Women's and Children's Health Network (AU)
- KU Leuven (BE)
- Corresponding author
- McCulloch, Timothy M.
- Venue
- The Laryngoscope
- Publisher
- Wiley
- Published
- 2012-10-15
- Volume
- 123
- Issue
- 3
- Pages
- 713-720
- ISSN
- 0023-852X (ISSN-L)
- 1531-4995
- PMC
- PMC3648989
- OpenAlex
- W2038249593
- Cited by
- 34
- References
- 27
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 1 · 2023: 1 · 2022: 3 · 2021: 1 · 2020: 1 · 2019: 5 · 2018: 5 · 2017: 2 · 2016: 4 · 2015: 2 · 2014: 2 · 2013: 2
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- The Laryngoscope (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
- Funders
- National Institute on Deafness and Other Communication Disorders (R33DC011130, R21 DC011130A, R21DC011130, T32DC009401)
- Topics
- Health Sciences › Health Professions › Speech and Hearing › Dysphagia Assessment and Management
- Health Sciences › Medicine › Physiology › Voice and Speech Disorders
- Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
- Keywords
- impedance, artificial neural networks, multilayer perceptron, dysphagia, swallowing safety, aspiration, penetration, risk screening
- MeSH terms
- Adult, Aged, Aged, 80 and over, Algorithms, Deglutition, Female, Humans, Male, Manometry, Middle Aged, ROC Curve, Neural Networks, Computer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Claims read under definition version 3 (extract-v3) on 2026-09-28.
Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-09-28.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review