CoChat

Bringing GC–MS profiling of steroids into clinical applications

Choi, Man Ho, Chung, Bong Chul · 2015 · Mass Spectrometry Reviews
Cited by 39

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

Abnormalities of steroid biosynthesis and excretion are responsible for the development and prevention of endocrine disorders, such as metabolic syndromes, cancers, and neurodegenerative diseases. Due to their biochemical roles in endocrine system, qualitative and quantitative analysis of steroid hormones in various biological specimens is needed to elucidate their altered expression. Mass spectrometry (MS)‐based steroid profiling can reveal the states of metabolites in biological systems and provide comprehensive insights by allowing comparisons between metabolites present in cells, tissues, or organisms. In addition, the activities of many enzymes related to steroid metabolism often lead to hormonal imbalances that have serious consequences, and which are responsible for the progress of hormone‐dependent diseases. In contrast to immunoaffinity‐based enzyme assays, MS‐based methods are more reproducible in quantification. In particular, high‐resolution gas chromatographic (GC) separation of steroids with similar chemical structures can be achieved to provide rapid and reproducible results with excellent purification. GC–MS profiling therefore has been widely used for steroid analysis, and offers the basis for techniques that can be applied to large‐scale clinical studies. Recent advances in analytical technologies combined with inter‐disciplinary strategies, such as physiology and bioinformatics, will help in understanding the biochemical roles of steroid hormones. Therefore, comprehensive analytical protocols in steroid analysis for different research purposes may contribute to the elucidation of complex metabolic processes relevant to steroid function in many endocrine disorders, and in the identification of diagnostic biomarkers. © 2014 Wiley Periodicals, Inc. Mass Spec Rev 34: 219–236, 2015.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mas.21436

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 39

Metadata

Authors
Choi, M. H., & Chung, B. C.
Venue
Mass Spectrometry Reviews
Publisher
Wiley
Published
2014-06-25
Volume
34
Issue
2
Pages
219-236
ISSN
  • 0277-7037 (ISSN-L)
  • 1098-2787
OpenAlex
W1583168199
Cited by
39
References
16
FWCI
1.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bringing GC–MS profiling of steroids into clinical applications. https://app.cochat.ai/papers/10.1002/mas.21436
The paper
Choi, M. H., & Chung, B. C. (2015). Bringing GC–MS profiling of steroids into clinical applications. Mass Spectrometry Reviews. https://doi.org/10.1002/mas.21436

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.