The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
MRI‐only based synthetic CT generation using dense cycle consistent generative adversarial networks
Open accessAbstract
Purpose: Automated synthetic computed tomography (sCT) generation based on magnetic resonance imaging (MRI) images would allow for MRI‐only based treatment planning in radiation therapy, eliminating the need for CT simulation and simplifying the patient treatment workflow. In this work, the authors propose a novel method for generation of sCT based on dense cycle‐consistent generative adversarial networks (cycle GAN), a deep‐learning based model that trains two transformation mappings (MRI to CT and CT to MRI) simultaneously. Methods and materials: The cycle GAN‐based model was developed to generate sCT images in a patch‐based framework. Cycle GAN was applied to this problem because it includes an inverse transformation from CT to MRI, which helps constrain the model to learn a one‐to‐one mapping. Dense block‐based networks were used to construct generator of cycle GAN. The network weights and variables were optimized via a gradient difference (GD) loss and a novel distance loss metric between sCT and original CT. Results: Leave‐one‐out cross‐validation was performed to validate the proposed model. The mean absolute error (MAE), peak signal‐to‐noise ratio (PSNR), and normalized cross correlation (NCC) indexes were used to quantify the differences between the sCT and original planning CT images. For the proposed method, the mean MAE between sCT and CT were 55.7 Hounsfield units (HU) for 24 brain cancer patients and 50.8 HU for 20 prostate cancer patients. The mean PSNR and NCC were 26.6 dB and 0.963 in the brain cases, and 24.5 dB and 0.929 in the pelvis. Conclusion: We developed and validated a novel learning‐based approach to generate CT images from routine MRIs based on dense cycle GAN model to effectively capture the relationship between the CT and MRIs. The proposed method can generate robust, high‐quality sCT in minutes. The proposed method offers strong potential for supporting near real‐time MRI‐only treatment planning in the brain and pelvis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Unpaired image-to-image translation using cycle-consistent adversarial networks
Zhu, J.-Y., Park, T., Isola, P., & Efros, A. A. (2017) · 2017 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2017.244 · Cited by 23,602
N4ITK: Improved N3 Bias Correction
Tustison, N. J., Avants, B. B., Cook, P. A., Zheng, Y., Egan, A., Yushkevich, P. A., & Gee, J. C. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2046908 · Cited by 6,073
Low-Dose CT With a Residual Encoder-Decoder Convolutional Neural Network
Chen, H., Zhang, Y., Kalra, M. K., Lin, F., Chen, Y., Liao, P., Zhou, J., & Wang, G. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2715284 · Cited by 1,866
Fraass, B., Doppke, K., Hunt, M., Kutcher, G., Starkschall, G., Stern, R., & Van Dyke, J. (1998) · Medical Physics · doi:10.1118/1.598373 · Cited by 911
MR-based synthetic CT generation using a deep convolutional neural network method
Han, X. (2017) · Medical Physics · doi:10.1002/mp.12155 · Cited by 711
Medical Image Synthesis with Context-Aware Generative Adversarial Networks
Nie, D., Trullo, R., Lian, J., Petitjean, C., Ruan, S., Wang, Q., & Shen, D. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-66179-7_48 · Cited by 691
Medical Image Synthesis with Deep Convolutional Adversarial Networks
Nie, D., Trullo, R., Lian, J., Wang, L., Petitjean, C., Ruan, S., Wang, Q., & Shen, D. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2814538 · Cited by 625
Deep MR to CT Synthesis Using Unpaired Data
Wolterink, J. M., Dinkla, A. M., Savenije, M. H. F., Seevinck, P. R., van den Berg, C. A. T., & Išgum, I. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-68127-6_2 · Cited by 593
Deep Learning Based Imaging Data Completion for Improved Brain Disease Diagnosis
Li, R., Zhang, W., Suk, H.-I., Wang, L., Li, J., Shen, D., & Ji, S. (2014) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-10443-0_39 · Cited by 469
Statistical normalization techniques for magnetic resonance imaging
Shinohara, R. T., Sweeney, E. M., Goldsmith, J., Shiee, N., Mateen, F. J., Calabresi, P. A., Jarso, S., Pham, D. L., Reich, D. S., & Crainiceanu, C. M. (2014) · NeuroImage: Clinical · doi:10.1016/j.nicl.2014.08.008 · Cited by 425
A review of substitute CT generation for MRI-only radiation therapy
Edmund, J. M., & Nyholm, T. (2017) · Radiation Oncology · doi:10.1186/s13014-016-0747-y · Cited by 378
Radiotherapy planning using MRI
Schmidt, M. A., & Payne, G. S. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/22/r323 · Cited by 357
Mutic, S., Palta, J. R., Butker, E. K., Das, I. J., Huq, M. S., Loo, L.-N. D., Salter, B. J., McCollough, C. H., & Van Dyk, J. (2003) · Medical Physics · doi:10.1118/1.1609271 · Cited by 344
Johansson, A., Karlsson, M., & Nyholm, T. (2011) · Medical Physics · doi:10.1118/1.3578928 · Cited by 324
Johnstone, E., Wyatt, J. J., Henry, A. M., Short, S. C., Sebag-Montefiore, D., Murray, L., Kelly, C. G., McCallum, H. M., & Speight, R. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.08.043 · Cited by 317
Generating synthetic CTs from magnetic resonance images using generative adversarial networks
Emami, H., Dong, M., Nejad‐Davarani, S. P., & Glide‐Hurst, C. K. (2018) · Medical Physics · doi:10.1002/mp.13047 · Cited by 300
Estimating CT Image From MRI Data Using Structured Random Forest and Auto-Context Model
Huynh, T., Gao, Y., Kang, J., Wang, L., Zhang, P., Lian, J., & Shen, D. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2461533 · Cited by 282
Estimating CT Image from MRI Data Using 3D Fully Convolutional Networks
Nie, D., Cao, X., Gao, Y., Wang, L., & Shen, D. (2016) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-46976-8_18 · Cited by 256
Hsu, S.-H., Cao, Y., Huang, K., Feng, M., & Balter, J. M. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/23/8419 · Cited by 233
New developments in MRI for target volume delineation in radiotherapy
Khoo, V. S., & Joon, D. L. (2006) · The British Journal of Radiology · doi:10.1259/bjr/41321492 · Cited by 207
Uh, J., Merchant, T. E., Li, Y., Li, X., & Hua, C. (2014) · Medical Physics · doi:10.1118/1.4873315 · Cited by 187
Kazemifar, S., McGuire, S., Timmerman, R., Wardak, Z., Nguyen, D., Park, Y., Jiang, S., & Owrangi, A. (2019) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2019.03.026 · Cited by 164
Generating patient specific pseudo-CT of the head from MR using atlas-based regression
Sjölund, J., Forsberg, D., Andersson, M., & Knutsson, H. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/2/825 · Cited by 161
MRI simulation for radiotherapy treatment planning
Devic, S. (2012) · Medical Physics · doi:10.1118/1.4758068 · Cited by 158
Andreasen, D., Leemput, K. V., Hansen, R. H., Andersen, J. A. L., & Edmund, J. (2015) · Medical Physics · doi:10.1118/1.4914158 · Cited by 148
Cone Beam Computed Tomography Image Quality Improvement Using a Deep Convolutional Neural Network
Kida, S., Nakamoto, T., Nakano, M., Nawa, K., Haga, A., Kotoku, J., Yamashita, H., & Nakagawa, K. (2018) · Cureus · doi:10.7759/cureus.2548 · Cited by 147
Yang, X., Wu, N., Cheng, G., Zhou, Z., Yu, D. S., Beitler, J. J., Curran, W. J., & Liu, T. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.08.350 · Cited by 113
Self-citationChen, S., Qin, A., Zhou, D., & Yan, D. (2018) · Medical Physics · doi:10.1002/mp.13247 · Cited by 108
MRI tumor segmentation with densely connected 3D CNN
DSouza, A. M., Chen, L., Wu, Y., Abidin, A. Z., Xu, C., & Wismüller, A. (2018) · SPIE Medical Imaging: Image Processing · doi:10.1117/12.2293394 · Cited by 106
A voxel-based investigation for MRI-only radiotherapy of the brain using ultra short echo times
Edmund, J., Kjer, H. M., Leemput, K. V., Hansen, R. H., Andersen, J. A. L., & Andreasen, D. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/23/7501 · Cited by 99
Gudur, M. S. R., Hara, W. Y., Le, Q., Wang, L., Xing, L., & Li, R. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/21/6595 · Cited by 96
Torrado-Carvajal, Á., Herraiz, J. L., Alcaín, E., Montemayor, A. S., García‐Cañamaque, L., Hernandez-Tamames, J. A., Rozenholc, Y., & Malpica, N. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.156299 · Cited by 91
Wang, T., Manohar, N., Lei, Y., Dhabaan, A., Shu, H. G., Liu, T., Curran, W. J., & Yang, X. (2018) · Medical dosimetry · doi:10.1016/j.meddos.2018.06.008 · Cited by 68
Self-citationShafai‐Erfani, G., Wang, T., Lei, Y., Tian, S., Patel, P. R., Jani, A. B., Curran, W. J., Liu, T., & Yang, X. (2019) · Medical dosimetry · doi:10.1016/j.meddos.2019.01.002 · Cited by 42
Self-citationEffects of Field-Map Distortion Correction on Resting State Functional Connectivity MRI
Togo, H., Rokicki, J., Yoshinaga, K., Hisatsune, T., Matsuda, H., Haga, N., & Hanakawa, T. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00656 · Cited by 40
Andreasen, D., Edmund, J., Zografos, V., Menze, B. H., & Leemput, K. V. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2216924 · Cited by 34
Cited by
Deep learning in medical image registration: a review
Fu, Y., Lei, Y., Wang, T., Curran, W. J., Liu, T., & Yang, X. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab843e · Cited by 661
Self-citationArtificial intelligence and machine learning for medical imaging: A technology review
Barragán-Montero, A., Javaid, U., Valdés, G., Nguyen, D., Desbordes, P., Macq, B., Willems, S., Vandewinckele, L., Holmström, M., Löfman, F., et al. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.04.016 · Cited by 450
Vandewinckele, L., Claessens, M., Dinkla, A., Brouwer, C., Crijns, W., Verellen, D., & van Elmpt, W. (2020) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2020.09.008 · Cited by 321
A review on medical imaging synthesis using deep learning and its clinical applications
Wang, T., Lei, Y., Fu, Y., Wynne, J. F., Curran, W. J., Liu, T., & Yang, X. (2021) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.13121 · Cited by 279
Self-citationA review of deep learning based methods for medical image multi-organ segmentation
Fu, Y., Lei, Y., Wang, T., Curran, W. J., Liu, T., & Yang, X. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.05.003 · Cited by 270
Self-citation
Metadata
- Authors
- Lei, Y., Harms, J., Wang, T., Liu, Y., Shu, H., Jani, A. B., Curran, W. J., Mao, H., Liu, T., & Yang, X.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2019-06-12
- Volume
- 46
- Issue
- 8
- Pages
- 3565-3581
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2945263066
- Cited by
- 297
- References
- 37
- FWCI
- 29.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.