Comparison of diffusion‐weighted high‐resolution CBF and spin‐echo BOLD fMRI at 9.4 T
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The quantification of blood oxygenation‐level dependent (BOLD) functional MRI (fMRI) signals is closely related to cerebral blood flow (CBF) change; therefore, understanding the exact relationship between BOLD and CBF changes on a pixel‐by‐pixel basis is fundamental. In this study, quantitative CBF changes induced by neural activity were used to quantify BOLD signal changes during somatosensory stimulation in α‐chloralose‐anesthetized rats. To examine the influence of fast‐moving vascular spins in quantifying CBF, bipolar gradients were employed. Our data show no significant difference in relative CBF changes obtained with and without bipolar gradients. To compare BOLD and CBF signal changes induced by neural stimulation, a spin‐echo (SE) sequence with long SE time of 40 ms at 9.4 T was used in conjunction with an arterial spin labeling technique. SE BOLD changes were quantitatively correlated to CBF changes on a pixel‐by‐pixel and animal‐by‐animal basis. Thus, SE BOLD‐based fMRI at high magnetic fields allows a quantitative comparison of functional brain activities across brain regions and subjects. Magn Reson Med 47:736–741, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fox, P. T., & Raichle, M. E. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.4.1140 · Cited by 2,056 · cited 1×
“Since relative CBF changes are linearly correlated to metabolic changes (1,25), SE BOLD signal changes can also be used to indicate the strength of metabolic activity in the brain.”
BackgroundOgawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772 · cited 4×
“BOLD contrast is very sensitive to susceptibility changes within and around large draining veins, especially in gradient-echo (GE) based fMRI techniques (10).”
BackgroundMethodInfluentialSelf-citationStimulated changes in localized cerebral energy consumption under anesthesia
Shulman, R. G., Rothman, D. L., & Hyder, F. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.6.3245 · Cited by 93 · cited 1×
“It has been reported that -chloralose anesthesia reduces the baseline metabolic rate of glucose (CMRglc) and CBF dramatically by 65% compared to the awake condition, while it does not alter those in stimulated conditions (3,29,30).”
Background
Cited by
Biophysical and Physiological Origins of Blood Oxygenation Level-Dependent fMRI Signals
Kim, S.-G., & Ogawa, S. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.23 · Cited by 547
Self-citationWhat can we see with IVIM MRI?
Le Bihan, D. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.062 · Cited by 498
Uludağ, K., Müller-Bierl, B., & Uğurbil, K. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.051 · Cited by 450
“As mentioned above, the IV signal can experimentally be attenuated by employing diffusion-weighting bi-polar gradients (Boxerman et al., 1995a; Duong et al., 2003; Le Bihan, 2003; Lee et al., 1999, 2002; Song et al., 1994, 1995, 2003).”
MethodDuong, T. Q., Yacoub, E., Adriany, G., Hu, X., Uǧurbil, K., & Kim, S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10472 · Cited by 360
Self-citationYacoub, E., Shmuel, A., Logothetis, N., & Uğurbil, K. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.05.020 · Cited by 308
Intravoxel Incoherent Motion Perfusion MR Imaging: A Wake-Up Call
Le Bihan, D. (2008) · Radiology · doi:10.1148/radiol.2493081301 · Cited by 298
Zhao, F., Wang, P., Hendrich, K., Ugurbil, K., & Kim, S.-G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.11.013 · Cited by 266
Self-citationPerfusion Imaging Using Arterial Spin Labeling
Golay, X., Hendrikse, J., & Lim, T. C. C. (2004) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-200402000-00003 · Cited by 256
Magnetic Resonance Imaging at 3.0 Tesla: Challenges and Advantages in Clinical Neurological Imaging
Frayne, R., Goodyear, B. G., Dickhoff, P., Lauzon, M. L., & Sevick, R. J. (2003) · Investigative Radiology · doi:10.1097/01.rli.0000073442.88269.c9 · Cited by 212
“Nonetheless, as field strength increases the BOLD effect becomes dominated by small vessels, making SE EPI the more probable technique of choice.(56,59) However, more RF power is then required and RF power deposition is a concern at high magnetic field (see previous discussion).”
BackgroundZhao, F., Zhao, T., Zhou, L., Wu, Q., & Hu, X. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.07.063 · Cited by 194
“…stimulation of paw is an interesting animal model for fMRI because of the wealth of existing fMRI data (Duong et al., 2000; Keilholz et al., 2004; Lee et al., 2002; Silva and Koretsky, 2002) and data from other modalities such as optical imaging and electrophysiological recording (Masamoto et…”
BackgroundQuantifying the spatial resolution of the gradient echo and spin echo BOLD response at 3 Tesla
Parkes, L. M., Schwarzbach, J. V., Bouts, A. A., Deckers, R. H. R., Pullens, P., Kerskens, C. M., & Norris, D. G. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20712 · Cited by 187
Imaging at ultrahigh magnetic fields: History, challenges, and solutions
Uğurbil, K. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.007 · Cited by 173
“, (Lee et al., 1999; Duong et al., 2000, 2001; Lee et al., 2002; Harel et al., 2006)), David Rayner and I started discussing the prospect of a high field human system during the ISMAR meeting in Sydney in 1995, where I gave a talk.”
BackgroundInfluentialNorris, D. G. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10390 · Cited by 171
“This is similar to the behavior of spin-echo BOLD at 7 T, and, indeed, a high correspondence between perfusion and spin-echo BOLD has been found to exist in the rat brain at these very high field strengths (94).”
Method
Metadata
- Authors
- Lee, S., Silva, A. C., & Kim, S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-03-28
- Volume
- 47
- Issue
- 4
- Pages
- 736-741
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2113843190
- Cited by
- 65
- References
- 3
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.