Detunable transverse electromagnetic (TEM) volume coil for high‐field NMR
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Most high‐field MRI systems do not have the actively detuned body coils that are integral to clinical systems operating at 1.5T and lower field strengths. Therefore, many clinical applications requiring homogeneous volume excitation in combination with local surface coil reception are not easily implemented at high fields. To solve this problem for neuroimaging applications, actively detunable transverse electromagnetic (TEM) head coils were developed to be used with receive‐only surface coils for signal‐to‐noise ratio (SNR) gains and improved spatial coverage from homogeneously excited regions. These SNR and field of view (FOV) gains were achieved by application of a detunable TEM volume coil to human brain imaging at 4T. Magn Reson Med 47:990–1000, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890
Self-citation
Cited by
Kelly, C., de Zubicaray, G., Di Martino, A., Copland, D. A., Reiss, P. T., Klein, D. F., Castellanos, F. X., Milham, M. P., & McMahon, K. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.0810-09.2009 · Cited by 292
“Functional imaging Functional imaging data were acquired using a 4T Bruker MedSpec system equipped with a transverse electromagnetic head coil (Vaughan et al., 2002).”
MethodMagnetic Resonance Imaging at 3.0 Tesla: Challenges and Advantages in Clinical Neurological Imaging
Frayne, R., Goodyear, B. G., Dickhoff, P., Lauzon, M. L., & Sevick, R. J. (2003) · Investigative Radiology · doi:10.1097/01.rli.0000073442.88269.c9 · Cited by 212
Action word meaning representations in cytoarchitectonically defined primary and premotor cortices
Postle, N., McMahon, K. L., Ashton, R., Meredith, M., & de Zubicaray, G. I. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.08.006 · Cited by 206
“A transverse electromagnetic (TEM) head coil was used for radiofrequency transmission and reception (Vaughan et al., 2002).”
MethodWiesinger, F., Van de Moortele, P., Adriany, G., De Zanche, N., Ugurbil, K., & Pruessmann, K. P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20281 · Cited by 198
Self-citationImaging at ultrahigh magnetic fields: History, challenges, and solutions
Uğurbil, K. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.007 · Cited by 173
Metadata
- Authors
- Vaughan, J. T., Adriany, G., Garwood, M., Yacoub, E., Duong, T., DelaBarre, L., Andersen, P., & Ugurbil, K.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-04-23
- Volume
- 47
- Issue
- 5
- Pages
- 990-1000
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2138274620
- Cited by
- 128
- References
- 1
- FWCI
- 3.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detunable transverse electromagnetic (TEM) volume coil for high‐field NMR. https://app.cochat.ai/papers/10.1002/mrm.10141
- The paper
- Vaughan, J. T., Adriany, G., Garwood, M., Yacoub, E., Duong, T., DelaBarre, L., Andersen, P., & Ugurbil, K. (2002). Detunable transverse electromagnetic (TEM) volume coil for high‐field NMR. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10141
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.