On the timing characteristics of the apparent diffusion coefficient contrast in fMRI
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
For the past 10 years, functional MRI (fMRI) has seen rapid progress in both clinical and basic science research. Most of the imaging techniques are based on the blood oxygenation level‐dependent (BOLD) contrast which arises from the field perturbation of the paramagnetic deoxyhemoglobin due to the mismatch between the local oxygen demand and delivery. Because the changes of oxygenation level take place mostly in the veins, the dominant signal sources of the BOLD signal are intra‐ and extravascular proton pools of the veins. Perfusion imaging methods, developed parallel to the BOLD technique, seek to quantify the blood flow and perfusion. Recently, perfusion imaging using arterial spin tagging methods have been used to study brain function by investigating the changes of the blood flow and perfusion during brain activation, thereby generating an alternative contrast mechanism to the functional brain imaging. Since most of these methods require tagging pulse and wait time for blood to be delivered to the imaged slice, the temporal resolution may not be optimal. Dynamic intravoxel incoherent motion (IVIM) weighting schemes using apparent diffusion coefficient (ADC) contrast were suggested to image the relative changes of the in‐plane blood flow during brain function. In this report, it was demonstrated that, in addition to the spatial discrepancies of the activated areas, the time course based on the ADC contrast consistently precedes that from the BOLD contrast with timing offset on the order of 1 sec. Since arterial networks would have different spatial locations and preceding temporal characters, the findings in this report are indicative that the ADC contrast is sensitive to the arterial blood flow changes. Magn Reson Med 48:385–388, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772 · cited 1×
“The common blood oxygenation level-dependent (BOLD) (7) signals arise mostly from the vascular networks that experience oxygenation level changes.”
BackgroundDiffusion weighted fMRI at 1.5 T
Song, A. W., Wong, E. C., Tan, S. G., & Hyde, J. S. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350204 · Cited by 208 · cited 1×
“Previous studies showed that diffusion-weighted methods can be used to modulate the BOLD signal (12,13).”
BackgroundSelf-citation
Cited by
Intravoxel Incoherent Motion Perfusion MR Imaging: A Wake-Up Call
Le Bihan, D. (2008) · Radiology · doi:10.1148/radiol.2493081301 · Cited by 298
Functional magnetic resonance imaging: A review of methodological aspects and clinical applications
Hennig, J., Speck, O., Koch, M. A., & Weiller, C. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10330 · Cited by 100
“Measurements of intravoxel incoherent motion (IVIM) using the same Stejskal-Tanner technique, but with reduced b-factor, have recently been shown to also lead to observable effects (68).”
MethodEvidence for a vascular contribution to diffusion FMRI at high b value
Miller, K. L., Bulte, D. P., Devlin, H., Robson, M. D., Wise, R. G., Woolrich, M. W., Jezzard, P., & Behrens, T. E. J. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0707257105 · Cited by 98
Kershaw, J., Tomiyasu, M., Kashikura, K., Hirano, Y., Nonaka, H., Hirano, M., Ikehira, H., Kanno, I., & Obata, T. (2009) · NMR in Biomedicine · doi:10.1002/nbm.1391 · Cited by 14
“and veins is more quickly attenuated than that from smaller vessels such as arterioles, capillaries and venules (4,5).”
Background
Metadata
- Authors
- Gangstead, S. L., & Song, A. W.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-07-31
- Volume
- 48
- Issue
- 2
- Pages
- 385-388
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2087704455
- Cited by
- 38
- References
- 4
- FWCI
- 1.66
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On the timing characteristics of the apparent diffusion coefficient contrast in fMRI. https://app.cochat.ai/papers/10.1002/mrm.10189
- The paper
- Gangstead, S. L., & Song, A. W. (2002). On the timing characteristics of the apparent diffusion coefficient contrast in fMRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10189
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.