Effects of equilibrium exchange on diffusion‐weighted NMR signals: The diffusigraphic “shutter‐speed”

Open access
Lee, Jing‐Huei, Springer, Charles S. · 2003 · Magnetic Resonance in Medicine
Cited by 94

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

A general picture is presented of the implications for diffusion‐weighted NMR signals of the parsimonious two‐site‐exchange (2SX) paradigm. In particular, it is shown that the diffusigraphic “shutter‐speed,” τ−1 ≡ |q 2(D A – D B)|, is a useful concept. The “wave‐number” q has its standard definition (given in the text), and D A and D B are the apparent diffusion coefficients (ADCs) of molecules in the two “sites,” A and B, if there is no exchange between them. At low gradient strengths (center of q‐space), τ−1 is less than rate constants for intercompartmental water molecule exchange in most tissue cases. Thus, the exchange reaction appears fast. However, q is increased during the course of most experiments and, as it is, the shutter‐speed becomes “faster” and the exchange reaction, the kinetics of which do not change, appears to slow down. This causes a multiexponential behavior in the diffusion‐weighting dimension, b, which also has its standard definition. This picture is found to be in substantial agreement with a number of different experimental observations. It is applied here to literature 1 H 2 O data from a yeast cell suspension and from the human and the rat brain. Since the equilibrium transcytolemmal water exchange reaction appears to be in the fast‐exchange‐limit at small b, the initial slope represents the weighted‐average of the ADCs of intra‐ and extracellular water. Of course, in tissue the former is in the significant majority. Furthermore, a consideration of reasonable values for the other 2SX parameters suggests that, for resting brain tissue, the intracellular water ADC may be larger than the extracellular water ADC. There are some independent inferences of this, which would have ramifications for many applications of diffusion‐weighted MRI. Magn Reson Med 49:450–458, 2003. Published 2003 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10402

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Lee, J., & Springer, C. S.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2003-03
Volume
49
Issue
3
Pages
450-458
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2016198779
Cited by
94
References
4
FWCI
6.21
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.