The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Arterial transit time imaging with flow encoding arterial spin tagging (FEAST)
Abstract
Arterial spin labeling (ASL) perfusion imaging provides direct and absolute measurement of cerebral blood flow (CBF). Arterial transit time is a related physiological parameter reflecting the duration for the labeled spins to reach the brain region of interest. Most of the existing ASL approaches to assess arterial transit time rely on multiple measurements at various postlabeling delay times, and thus are vulnerable to motion artifact as well as computational error. We describe the use of flow encoding arterial spin tagging (FEAST) technique to measure tissue transit time, which can be derived from the ratio between the ASL signals measured with and without appropriate bipolar gradients. In the present study, we provided a theoretical framework and carried out an experimental validation during steady‐state imaging. The global mean tissue transit time was ∼1100 and 1400 ms for two conditions of bipolar gradients with specific encoding velocity (Venc) of 29 and 8 mm/sec, respectively. The mean tissue transit time measured within cerebral vascular territories was shortest in the deep middle cerebral artery (MCA) territory. Application of the FEAST technique in two patients with cerebrovascular disease demonstrated prolonged tissue transit times in the affected vascular territories which were consistent with results from other MR imaging modalities. Magn Reson Med 50:599–607, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Alsop, D. C., & Detre, J. A. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199611000-00019 · Cited by 754
Self-citationArterial territories of the human brain: Cerebral hemispheres
Tatu, L., Moulin, T., Bogousslavsky, J., & Duvernoy, H. (1998) · Neurology · doi:10.1212/wnl.50.6.1699 · Cited by 614
Wong, E. C., Buxton, R. B., & Frank, L. R. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<237::aid-nbm475>3.0.co;2-x · Cited by 584
Chalela, J. A., Alsop, D. C., Gonzalez-Atavales, J. B., Maldjian, J. A., Kasner, S. E., & Detre, J. A. (2000) · Stroke · doi:10.1161/01.str.31.3.680 · Cited by 481
Self-citationAssessment of cerebral blood flow in Alzheimer's disease by spin-labeled magnetic resonance imaging
Alsop, D. C., Detre, J. A., & Grossman, M. (2000) · Annals of Neurology · doi:10.1002/1531-8249(200001)47:1<93::aid-ana15>3.0.co;2-8 · Cited by 409
Self-citationMultisection cerebral blood flow MR imaging with continuous arterial spin labeling.
Alsop, D. C., & Detre, J. A. (1998) · Radiology · doi:10.1148/radiology.208.2.9680569 · Cited by 404
Self-citationCarpenter, M. B. (1978) · Andalas University Repository (Andalas University) · Cited by 402
Cerebral hemodynamic impairment: Methods of measurement and association with stroke risk
Derdeyn, C. P., Grubb, R. L., & Powers, W. J. (1999) · Neurology · doi:10.1212/wnl.53.2.251 · Cited by 397
Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla
Wang, J., Alsop, D. C., Li, L., Listerud, J., Gonzalez‐At, J. B., Schnall, M. D., & Detre, J. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10211 · Cited by 369
Self-citationYe, F. Q., Mattay, V. S., Jezzard, P., Frank, J. A., Weinberger, D. R., & McLaughlin, A. C. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370215 · Cited by 294
Calamante, F., Gadian, D. G., & Connelly, A. (2002) · Stroke · doi:10.1161/01.str.0000014208.05597.33 · Cited by 283
Leigh, N. (1986) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.49.3.340-b · Cited by 258
Wong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400303 · Cited by 250
Noninvasive MRI evaluation of cerebral blood flow in cerebrovascular disease
Detre, J. A., Alsop, D. C., Vives, L. R., Maccotta, L., Teener, J. W., & Raps, E. C. (1998) · Neurology · doi:10.1212/wnl.50.3.633 · Cited by 209
Self-citationMultislice imaging of quantitative cerebral perfusion with pulsed arterial spin labeling
Yang, Y., Frank, J. A., Hou, L., Ye, F. Q., McLaughlin, A. C., & Duyn, J. H. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390520 · Cited by 155
Arterial behavior and blood circulation in the brain
(1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90089-7 · Cited by 133
Potential and Pitfalls of Arterial Spin Labeling Based Perfusion Imaging Techniques for MRI
Wong, E. C. (2000) · Medical radiology · doi:10.1007/978-3-642-58716-0_6 · Cited by 40
Arterial Behavior and Blood Circulation in the Brain
Poser, C. M. (1987) · JAMA · doi:10.1001/jama.1987.03390190132041 · Cited by 33
Perfusion fMRI with Arterial Spin Labeling
Detre, J. A., & Alsop, D. C. (2000) · Medical radiology · doi:10.1007/978-3-642-58716-0_5 · Cited by 28
Self-citationDiffusion tensor mapping of the human brain using single-shot line scan imaging
Finsterbusch, J., & Frahm, J. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200009)12:3<400::aid-jmri5>3.0.co;2-c · Cited by 15
(1991) · Comparative Biochemistry and Physiology Part A Physiology · doi:10.1016/0300-9629(91)90052-e · Cited by 10
Use of Diffusible and Nondiffusible Tracers in Studies of Brain Perfusion
McLaughlin, A. C., Ye, F. Q., Berman, K. F., Mattay, V. S., Weinberger, D. R., & Frank, J. A. (2000) · Medical radiology · doi:10.1007/978-3-642-58716-0_4 · Cited by 4
Wheeler-Kingshott (2000) · doi:10.1002/1522-2594(200011)44:5
Grieve (2000) · doi:10.1002/(sici)1522-2594(200005)43:5
Cited by
Alsop, D. C., Detre, J. A., Golay, X., Günther, M., Hendrikse, J., Hernandez‐Garcia, L., Lu, H., MacIntosh, B. J., Parkes, L. M., Smits, M., et al. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25197 · Cited by 2,206
Self-citationPerfusion MRI: The Five Most Frequently Asked Technical Questions
Essig, M., Shiroishi, M. S., Nguyen, T. B., Saake, M., Provenzale, J. M., Enterline, D., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9543 · Cited by 366
Non-invasive measurement of perfusion: a critical review of arterial spin labelling techniques
Petersen, E. T., Zimine, I., Ho, Y.-C. L., & Golay, X. (2006) · The British Journal of Radiology · doi:10.1259/bjr/67705974 · Cited by 352
Perfusion MRI: The Five Most Frequently Asked Clinical Questions
Essig, M., Nguyen, T. B., Shiroishi, M. S., Saake, M., Provenzale, J. M., Enterline, D. S., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9544 · Cited by 344
Mosconi, L., Berti, V., Dyke, J., Schelbaum, E., Jett, S., Loughlin, L., Jang, G., Rahman, A., Hristov, H., Pahlajani, S., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-90084-y · Cited by 308
Metadata
- Authors
- Wang, J., Alsop, D. C., Song, H. K., Maldjian, J. A., Tang, K., Salvucci, A. E., & Detre, J. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2003-08-20
- Volume
- 50
- Issue
- 3
- Pages
- 599-607
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2118799950
- Cited by
- 275
- References
- 24
- FWCI
- 5.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.