CoChat

High‐resolution 1H NMR and magic angle spinning NMR spectroscopic investigation of the biochemical effects of 2‐bromoethanamine in intact renal and hepatic tissue

Open access
Garrod, S., Humpher, E., Connor, S.C., Connelly, J.C., Spraul, M., Nicholson, J.K., Holmes, E. · 2001 · Magnetic Resonance in Medicine
Cited by 96

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The metabolic consequences of xenobiotic‐induced toxicity were investigated using high‐resolution magic angle spinning (MAS) NMR spectroscopy of intact tissue. Renal papillary necrosis (RPN) was induced in Sprague‐Dawley rats (n = 12) via a single i.p. dose of 250 mg/kg 2‐bromoethanamine (BEA) hydrobromide. At 2, 4, 6, and 24 h after treatment with BEA, three animals were killed and tissue samples were obtained from liver, renal cortex, and renal medulla. Tissue samples were also removed at 2 and 24 h from matched controls (n = 6). 1 H MAS NMR spectroscopic techniques were used to analyze samples of intact tissue (∼10 mg). Decreased levels of nonperturbing renal osmolytes (glycerophosphocholine, betaine, and myo‐inositol) were observed in the renal papilla of BEA‐treated animals at 6 and 24 h postdose (p.d.), concomitant with a relative increase in the tissue concentration of creatine. Increased levels of glutaric acid were found in all tissues studied in BEA‐treated animals at 4 and 6 h p.d., indicating the inhibition of mitochondrial fatty acyl CoA dehydrogenases and mitochondrial dysfunction. Increased levels of trimethylamine‐N‐oxide occurred in the renal cortex at 6 h p.d. Changes in the metabolite profile of liver included an increase in the relative concentrations of triglycerides, lysine, and leucine. The novel application of 1 H MAS NMR to the biochemical analysis of intact tissues following a toxic insult highlights the potential of this technique as a toxicological probe in providing a direct link between urinary biomarkers of toxicity and histopathological evaluation of toxicological lesions. Magn Reson Med 45:781–790, 2001. © 2001 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1106

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Garrod, S., Humpher, E., Connor, S. C., Connelly, J. C., Spraul, M., Nicholson, J. K., & Holmes, E.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2001-04-16
Volume
45
Issue
5
Pages
781-790
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2043201031
Cited by
96
References
1
FWCI
2.50
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.