The intrinsic signal-to-noise ratio in NMR imaging
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
The fundamental limit for NMR imaging is set by an intrinsic signal‐to‐noise ratio (SNR) for a particular combination of rf antenna and imaging subjects. The intrinsic SNR is the signal from a small volume of material in the sample competing with electrical noise from thermally generated, random noise currents in the sample. The intrinsic SNR has been measured for a number of antenna‐body section combinations at several different values of the static magnetic field and is proportional to B 0 . We have applied the intrinsic and system SNR to predict image SNR and have found satisfactory agreement with measurements on images. The relationship between SNR and pixel size is quite different in NMR than it is with imaging modalities using ionizing radiation, and indicates that the initial choice of pixel size is crucial in NMR. The analog of “contrast‐detail‐dose” plots for ionizing radiation imaging modalities is the “contrast‐detail‐time” plot in NMR, which should prove useful in choosing a suitable pixel array to visualize a particular anatomical detail for a given NMR receiving antenna. © 1986 Academic Press, Inc.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Imaging at a higher spatial resolution can decrease partial volume effects but can come at the cost of a reduced MRI signal-to-noise ratio (SNR) (Edelstein et al., 1986).”
From Phasic and sustained fear in humans elicits distinct patterns of brain activity (2011) · cites this paper as Edelstein et al., 1986
Citations
Cites
Bottomley, P. A., Foster, T. H., Argersinger, R. E., & Pfeifer, L. M. (1984) · Medical Physics · doi:10.1118/1.595535 · Cited by 1,192
The Sensitivity Performance of the Human Eye on an Absolute Scale*
Rose, A. (1948) · Journal of the Optical Society of America · doi:10.1364/josa.38.000196 · Cited by 931
Image Reconstruction from Projections
(2004) · Biomedical Engineering · doi:10.1201/9780203492543.ch9 · Cited by 915
Spin warp NMR imaging and applications to human whole-body imaging
Edelstein, W. A., Hutchison, J. M. S., Johnson, G., & Redpath, T. (1980) · Physics in Medicine & Biology · doi:10.1088/0031-9155/25/4/017 · Cited by 803
Self-citationThe sensitivity of the zeugmatographic experiment involving human samples
Hoult, D. I., & Lauterbur, P. C. (1979) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(79)90019-2 · Cited by 776
Kumar, A., Welti, D., & Ernst, R. R. (1975) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(75)90224-3 · Cited by 311
Comparison of linear and circular polarization for magnetic resonance imaging
Glover, G. H., Hayes, C. E., Pelc, N. J., Edelstein, W. A., Mueller, O. M., Hart, H. R., Hardy, C. J., O'Donnell, M., & Barber, W. D. (1985) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(85)90349-x · Cited by 265
Self-citationEdelstein, W. A., Bottomley, P. A., & Pfeifer, L. M. (1984) · Medical Physics · doi:10.1118/1.595484 · Cited by 230
Self-citationSignal, Noise, and Contrast in Nuclear Magnetic Resonance (NMR) Imaging
Edelstein, W. A., Bottomley, P. A., Hart, H. R., & Smith, L. S. (1983) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198306000-00001 · Cited by 201
Self-citationImage Reconstruction from Projections
Norton-Wayne, L. (1980) · Optica Acta: International Journal of Optics · doi:10.1080/713820221 · Cited by 184
Research works printed but not linked: 2
- W. A.Edelstein T. H.Foster andJ. F.Schenck Society for Magnetic Resonance in Medicine Foruth Annual Meeting Abstracts pp.964–965 1985.
- Glover G. H., 1986, J. Magn. Reson., 64, 255
Cited by
Items 401–500 of 858
A Near‐Field Coupling Array Enables Parallel Imaging and SNR Gain in MRI
Mo, Z., Che, S., Du, F., Xiao, E., Chen, Q., Li, N., Jia, S., Tie, C., Wu, B. H., Zhang, X., et al. (2025) · Advanced Science · doi:10.1002/advs.202503481 · Cited by 14
Functional coupling between CA3 and laterobasal amygdala supports schema dependent memory formation
Yousuf, M., Packard, P. A., Fuentemilla, L., & Bunzeck, N. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118563 · Cited by 14
Signal‐to‐noise ratio versus field strength for small surface coils
Pohmann, R., Avdievich, N. I., & Scheffler, K. (2024) · NMR in Biomedicine · doi:10.1002/nbm.5168 · Cited by 14
Hyperpolarized Molecules in Solution
Ardenkjær‐Larsen, J. H., Jóhannesson, H., Petersson, J. S., & Wolber, J. (2011) · Methods in molecular biology · doi:10.1007/978-1-61779-219-9_11 · Cited by 14
O'Mara, D. M., Berges, A. J., Fritz, J. M., & Weiss, C. R. (2020) · Clinical Imaging · doi:10.1016/j.clinimag.2020.04.012 · Cited by 14
RODRIGUEZ, D., Rylander, H., Vigen, K. K., & ADAMS, W. M. (2009) · Veterinary Radiology & Ultrasound · doi:10.1111/j.1740-8261.2009.01574.x · Cited by 14
Sensitivity calculations and comparisons for shielded elliptical and circular birdcage coils
Zanche, N. D., & Allen, P. S. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10039 · Cited by 14
Girard, O. M., Ginéfri, J., Poirier‐Quinot, M., & Darrasse, L. (2007) · Review of Scientific Instruments · doi:10.1063/1.2825241 · Cited by 14
Accuracy of accelerated cine MR imaging at 3 Tesla in longitudinal follow-up of cardiac function
Sandner, T. A., Houck, P. D., Runge, V. M., Sincleair, S. T., Huber, A. M. A., Theisen, D., Reiser, M. F., & Wintersperger, B. J. (2008) · European Radiology · doi:10.1007/s00330-008-0993-y · Cited by 14
The absolute signal-to-noise ratio in MRI acceptance testing
McRobbie, D. W. (1996) · British Journal of Radiology · doi:10.1259/0007-1285-69-827-1045 · Cited by 14
The petal resonator: a new approach to surface coil design for NMR imaging and spectroscopy
Mansfield, P. (1988) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/21/11/015 · Cited by 14
The periaqueductal gray in chronic low back pain: dysregulated neurotransmitters and function
Sirucek, L., Schoenmacker, I. D., Gorrell, L. M., Lütolf, R., Langenfeld, A., Baechler, M., Wirth, B., Hubli, M., Zoelch, N., & Schweinhardt, P. (2025) · Pain · doi:10.1097/j.pain.0000000000003617 · Cited by 13
High-resolution multi-shot diffusion imaging of structural networks in healthy neurocognitive aging
Merenstein, J. L., Zhao, J., Mullin, H. A., Rudolph, M. D., Song, A. W., & Madden, D. J. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120191 · Cited by 13
Algarín, J. M., Breuer, F., Behr, V. C., & Freire, M. J. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2377792 · Cited by 13
An actively decoupled dual transceiver coil system for continuous ASL at 7 T
Stafford, R. B., Woo, M., Oh, S., Dolui, S., Zhao, T., Kim, Y.-B., Detre, J. A., Cho, Z., & Lee, J. (2016) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.22165 · Cited by 13
Radiofrequency Field Calculations for High Field MRI
Collins, C. M. (2007) · Springer eBooks · doi:10.1007/978-0-387-49648-1_8 · Cited by 13
The role of MRI in young adolescent girls with hematocolpos
Kapsalaki, E. Z., Daponte, A. I., Deligeoroglou, E., Zavos, A., Fezoulidis, I. V., & Messinis, I. E. (2011) · European Journal of Radiology Extra · doi:10.1016/j.ejrex.2011.02.009 · Cited by 13
On MR experiment design with quadratic regularization
Haldar, J. P., & Liang, Z. (2011) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2011.5872726 · Cited by 13
Reischauer, C., Vorburger, R. S., Wilm, B. J., Jaermann, T., & Boesiger, P. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23057 · Cited by 13
Hexagonal zero mode TEM coil: A single‐channel coil design for imaging multiple small animals
Lazović, J., Stojkovic, D. S., Collins, C. M., Yang, Q., Vaughan, J. T., & Smith, M. B. H. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20459 · Cited by 13
Maunder, A., Rao, M. R., Robb, F. J. L., & Wild, J. M. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27479 · Cited by 12
How ignoring physiological noise can bias the conclusions from fMRI simulation results
Welvaert, M., & Rosseel, Y. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.08.022 · Cited by 12
Sarıkaya, B., McKinney, A. M., Spilseth, B., & Truwit, C. L. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3323 · Cited by 12
Robb, J. S., Hu, C., & Peters, D. C. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28036 · Cited by 12
Chun, I. Y., Noh, S., Love, D. J., Talavage, T. M., Beckley, S., & Kisner, S. J. (2016) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2016.2610141 · Cited by 12
Taylor, A. J., Granwehr, J., Lesbats, C., Krupa, J. L., Six, J. S., Pavlovskaya, G. E., Thomas, N. R., Auer, D. P., Meersmann, T., & Faas, H. (2016) · PLoS ONE · doi:10.1371/journal.pone.0163704 · Cited by 12
Arcak, M., & Maidens, J. (2018) · Lecture notes in computer science · doi:10.1007/978-3-319-95246-8_4 · Cited by 12
An EM Simulation-Based Design Flow for Custom-Built MR Coils Incorporating Signal and Noise
Horneff, A., Eder, M., Hell, E., Ulrici, J., Felder, J., Rasche, V., & Anders, J. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2764160 · Cited by 12
Baek, A., Kim, H.-K., Yang, J.-U., Choi, G., Kim, M., Cho, A. E., Kim, Y., Kim, S., Sung, B., Yang, B. W., et al. (2020) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2020.02.015 · Cited by 12
Fischl, B. R. (2013) · Springer eBooks · doi:10.1007/978-3-642-37824-9_4 · Cited by 12
Parametric Imaging of Tumor Perfusion with Deuterium Magnetic Resonance Imaging
Bogin, L., Margalit, R., Ristau, H., Mispelter, J., & Degani, H. (2002) · Microvascular Research · doi:10.1006/mvre.2002.2411 · Cited by 12
Numerical Study of the SNR and SAR of MRI Coil Arrays
Rojas, R., & Rodriguez, A. O. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352511 · Cited by 12
Ding, X. Q., Finsterbusch, J., Wittkugel, O., Saager, C., Goebell, E., Fitting, T., Grzyska, U., Zeumer, H., & Fiehler, J. (2007) · Clinical Neuroradiology · doi:10.1007/s00062-007-7026-0 · Cited by 12
Magnetic resonance butterfly coils: Design and application for hyperpolarized 13C studies
Giovannetti, G., Frijia, F., Attanasio, S., Menichetti, L., Hartwig, V., Vanello, N., Ardenkjær‐Larsen, J. H., Marchi, D. D., Positano, V., Schulte, R. F., et al. (2013) · Measurement · doi:10.1016/j.measurement.2013.06.031 · Cited by 12
Transmit/receive headcoil for optimal 1H MR spectroscopy of the brain in paediatric patients at 3 T
Klomp, D. W. J., van der Graaf, M., Willemsen, M. A. A. P., van der Meulen, Y. M., Kentgens, A. P. M., & Heerschap, A. (2004) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-004-0039-7 · Cited by 12
van der Weijden, C. W. J., Gutmann, I. W., Somsen, J. F., Luurtsema, G., van der Goot, T., Arzanforoosh, F., Kramer, M. C. A., Buunk, A. M., de Vries, E. F. J., Rauscher, A., et al. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14134776 · Cited by 11
Hutton, C., Balteau, E., Lutti, A., Josephs, O., & Weiskopf, N. (2012) · PLoS ONE · doi:10.1371/journal.pone.0052075 · Cited by 11
Gietzen, C., Kaya, K., Janßen, J. P., Gertz, R. J., Terzis, R., Huflage, H., Grunz, J., Gietzen, T., Pennig, H., Çelik, E., et al. (2024) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2024.04.009 · Cited by 11
Multi-study fMRI outlooks on subcortical BOLD responses in the stop-signal paradigm
Isherwood, S. J., Kemp, S. A., Miletić, S., Stevenson, N., Bazin, P., & Forstmann, B. U. (2023) · eLife · doi:10.7554/elife.88652.4 · Cited by 11
Haemer, G. G., Vaidya, M. V., Collins, C. M., Sodickson, D. K., Wiggins, G. C., & Lattanzi, R. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27022 · Cited by 11
Cancer in the crosshairs: targeting cancer metabolism with hyperpolarized carbon‐13 MRI technology
von Morze, C., & Merritt, M. E. (2018) · NMR in Biomedicine · doi:10.1002/nbm.3937 · Cited by 11
How thin can you go? Performance of thin copper and aluminum RF coil conductors
Barta, R., Volotovskyy, V., Wachowicz, K., Fallone, B. G., & Zanche, N. D. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28540 · Cited by 11
Characterizing user behavior in online social networks: Analysis of the regular use of Facebook
Idrais, J., Moudene, Y. E., & Sabour, A. (2021) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijece.v11i4.pp3329-3337 · Cited by 11
Guerrero-Gonzalez, J. M., Surgent, O. J., Adluru, N., Kirk, G. R., Dean, D., Kecskemeti, S., Alexander, A. L., & Travers, B. G. (2022) · Frontiers in Integrative Neuroscience · doi:10.3389/fnint.2022.804743 · Cited by 11
“Early” Constrained Reconstruction Methods
Haldar, J. P., & Liang, Z. (2022) · Advances in magnetic resonance technology and applications · doi:10.1016/b978-0-12-822726-8.00014-2 · Cited by 11
Role of articulatory motor networks in perceptual categorization of speech signals: a 7T fMRI study
Lankinen, K., Ahveninen, J., Uluç, I., Daneshzand, M., Mareyam, A., KIRSCH, J. E., Polimeni, J. R., Healy, B. C., Tian, Q., Khan, S., et al. (2023) · Cerebral Cortex · doi:10.1093/cercor/bhad384 · Cited by 11
Nakazawa, H., Shibamoto, Y., Tsugawa, T., Mori, Y., Nishio, M., Takami, T., Komori, M., Hashizume, C., & Kobayashi, T. (2013) · Japanese Journal of Radiology · doi:10.1007/s11604-013-0262-0 · Cited by 11
Numerical Study of the Optimal Geometry of MRI Surface Coils
Rojas, R., & Rodriguez, A. O. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353183 · Cited by 11
Ultrahigh‐resolution quantitative spinal cord MRI at 9.4T
Geldschläger, O., Bosch, D., Avdievich, N. I., & Henning, A. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28455 · Cited by 11
Template-Based $B _{1}$ Inhomogeneity Correction in 3T MRI Brain Studies
Castro, M. A., Yao, J., Pang, Y., Lee, C., Baker, E. H., Butman, J. A., Evangelou, I. E., & Thomasson, D. M. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2053552 · Cited by 11
Interventional MRI: Tapering improves the distal sensitivity of the loopless antenna
Qian, D., El‐Sharkawy, A. M., Atalar, E., & Bottomley, P. A. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22152 · Cited by 11
Linear microstrip surface coil for MR imaging of the rat spinal cord at 4.7 T
Burian, M., & H�jek, M. (2004) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-004-0077-1 · Cited by 11
Effects of EPI readout bandwidth on measured activation map and BOLD response in fMRI experiments
Zou, P., Hutchins, S. B., Dutkiewicz, R. M., Li, C., & Ogg, R. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.01.004 · Cited by 11
Fast spectroscopic imaging strategies for potential applications in fMRI
Mulkern, R. V., Chen, N., Oshio, K., Panych, L. P., Rybicki, F. J., & Gambarota, G. (2004) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.011 · Cited by 11
Field Strength Dependence of Functional MRI Signals
Gati, J. S., Menon, R. S., & Rutt, B. K. (2000) · Medical radiology · doi:10.1007/978-3-642-58716-0_25 · Cited by 11
1H spectroscopic imaging of rat brain at 7 tesla
Fernández, E., Maudsley, A. A., Higuchi, T., & Weiner, M. W. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250111 · Cited by 11
FONDUE: Robust resolution-invariant denoising of MR images using Nested UNets
Adame‐Gonzalez, W., Brzezinski-Rittner, A., Zeighami, Y., Chakravarty, M. M., Farivar, R., & Dadar, M. (2024) · Imaging Neuroscience · doi:10.1162/imag_a_00374 · Cited by 10
Inter-Channel Correlation-Based EMI Noise Removal (ICER) for Shielding-Free Low-Field MRI
Huang, Y., Qu, S., Xie, Y., Wang, H., Zhang, X., & Zhang, X. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3534839 · Cited by 10
Hall, J. M., Shahnazian, D., & Krebs, R. M. (2024) · Imaging Neuroscience · doi:10.1162/imag_a_00336 · Cited by 10
Spectral decomposition of susceptibility artifacts for spectral‐spatial radiofrequency pulse design
Yang, C., Poser, B. A., Deng, W., & Stenger, V. A. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24208 · Cited by 10
Bier, E. A., Nouls, J. C., Wang, Z., He, M., Schrank, G., Morales‐Medina, N., Hashoian, R., Svetlik, H., Mugler, J. P., & Driehuys, B. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27836 · Cited by 10
Enjilela, R., MacMillan, B., McAloon, M., Petrov, O. V., Vashaee, S., & Balcom, B. J. (2019) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2019.106575 · Cited by 10
Breast coil design for low‐field mri
Komu, M. E. S., & Kormano, M. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910270115 · Cited by 10
Evaluation of common RF coil setups for MR imaging at ultrahigh magnetic field: a numerical study
Lu, J., Pang, Y., Wang, C., Wu, B. H., Vigneron, D. B., & Zhang, X. (2011) · International Symposium on Applied Sciences in Biomedical and Communication Technologies · doi:10.1145/2093698.2093768 · Cited by 10
Design and simulation of a dual-tuned 1H/23Na birdcage coil for MRS studies in human calf
Giovannetti, G., Valvano, G., Virgili, G., Giannoni, M., Flori, A., Frijia, F., Marchi, D. D., Hartwig, V., Landini, L., Aquaro, G. D., et al. (2015) · Applied Magnetic Resonance · doi:10.1007/s00723-015-0720-1 · Cited by 10
Seo, J., Han, Y., & Chung, J. (2022) · Sensors · doi:10.3390/s22051741 · Cited by 10
Error propagation model for microscopic magnetic resonance elastography shear-wave images
Othman, S. F., Zhou, X. J., Xu, H., Royston, T. J., & Magin, R. L. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2006.09.040 · Cited by 10
Lavdas, E., Mavroidis, P., Vassiou, K. G., Roka, V., Fezoulidis, I. V., & Vlychou, M. (2010) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2010.06.020 · Cited by 10
Improving sodium Magnetic Resonance in humans by design of a dedicated 23Na surface coil
Giovannetti, G., Pingitore, A., Positano, V., Marchi, D. D., Valvano, G., Gibiino, F., Aquaro, G. D., Lombardi, M., Landini, L., & Santarelli, M. F. (2014) · Measurement · doi:10.1016/j.measurement.2014.01.006 · Cited by 10
Technical Update on Magnetic Resonance Imaging of the Shoulder
Vieira, R. L. R., Rybak, L., & Recht, M. P. (2012) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2012.01.005 · Cited by 10
Sohn, C., Sevick, R. J., Frayne, R., Chang, H.-W., Kim, S.-P., & Kim, D.-K. (2009) · Korean Journal of Radiology · doi:10.3348/kjr.2010.11.1.19 · Cited by 10
Design Considerations for Ultra High Field MRI Magnet Systems
Bird, J. J., Houlden, D., Kerley, N., Rayner, D. L., Simkin, D., & Pittard, S. (2007) · Springer eBooks · doi:10.1007/978-0-387-49648-1_2 · Cited by 10
Encoding with frames in MRI and analysis of the signal-to-noise ratio
Xu, Z., & Chan, A. K. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.1000257 · Cited by 10
Roberts, H. R. S., Paley, M. N. J., Sams, V. R., Wilkinson, I. D., Lees, W. R., Hall-Craggs, M. A., & Bown, S. G. (1997) · Minimally Invasive Therapy & Allied Technologies · doi:10.3109/13645709709152825 · Cited by 10
In vivo hyperpolarization transfer in a clinical MRI scanner
von Morze, C., Reed, G. D., Larson, P. E. Z., Mammoli, D., Chen, A. P., Tropp, J. S., Criekinge, M. V., Ohliger, M. A., Kurhanewicz, J. V., Vigneron, D. B., et al. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27154 · Cited by 9
Park, M., Noh, H., & Park, N. (2020) · Scientific Reports · doi:10.1038/s41598-020-68651-6 · Cited by 9
Skin Effect Estimation in Radiofrequency Coils for Nuclear Magnetic Resonance Applications
Giovannetti, G., & Tiberi, G. (2016) · Applied Magnetic Resonance · doi:10.1007/s00723-016-0780-x · Cited by 9
Moody, K. L., Hollingsworth, N. A., Zhao, F., Nielsen, J., Noll, D. C., Wright, S. M., & McDougall, M. P. (2014) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2014.06.019 · Cited by 9
Spectral resolution enhancement by chemical shift imaging
Serša, I., & Macura, S. I. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2006.09.015 · Cited by 9
Magnetic resonance reconstruction from projections using half the data
Noll, D. C., Pauly, J. M., Nishimura, D. G., & Macovski, A. (1991) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.43428 · Cited by 9
A flexible coil array for high resolution magnetic resonance imaging at 7 Tesla
Frass‐Kriegl, R. (2014) · theses.fr (ABES) · doi:10.70675/bcec38d8zafeaz4a80z94bez634b2e5e9f0d · Cited by 9
Mustafa, Z. A., Ibraheem, B. A., GissmAllah, K. M., Elmahdi, R. E., & Omara, A. (2022) · Journal of Clinical Engineering · doi:10.1097/jce.0000000000000559 · Cited by 8
SNR in MI Catheter Receivers for MRI
Kardoulaki, E. M., Syms, R. R. A., YOUNG, I. R., & Rea, M. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2500226 · Cited by 8
A dedicated eight‐channel receive RF coil array for monkey brain MRI at 9.4 T
Li, M., Li, Y., Jin, J., Yang, Z., Zhang, B., Liu, Y., Song, M., Freakly, C., Ewald, W., Liu, F., et al. (2020) · NMR in Biomedicine · doi:10.1002/nbm.4369 · Cited by 8
van den Boom, M., Miller, K. J., Ramsey, N. F., & Hermes, D. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abda0d · Cited by 8
Robust PCA with Lw,∗ and L2,1 Norms: A Novel Method for Low-Quality Retinal Image Enhancement
Likassa, H. T., Chen, D., Chen, K., Wang, Y., & Zhu, W. (2024) · Journal of Imaging · doi:10.3390/jimaging10070151 · Cited by 8
Optimization of a transmit/receive surface coil for squirrel monkey spinal cord imaging
Lu, M., Wang, F., Chen, L. M., Gore, J. C., & Yan, X. (2020) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2020.02.011 · Cited by 8
In vivo imaging of the human brain at 1.5 T with 0.6-mm isotropic resolution
Oros‐Peusquens, A., Stöcker, T., Amunts, K., Zilles, K., & Shah, N. J. (2010) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2009.11.006 · Cited by 8
Partially orthogonal resonators for magnetic resonance imaging
Chacon‐Caldera, J., Malzacher, M., & Schad, L. R. (2017) · Scientific Reports · doi:10.1038/srep42347 · Cited by 8
Fetal MRI at Higher Field Strength
Stadlbauer, A., & Prayer, D. (2010) · Medical radiology · doi:10.1007/174_2010_27 · Cited by 8
Kardiale Funktionsanalyse mittels MRT
Sandner, T. A., Theisen, D., Bauner, K. U., Picciolo, M., Reiser, M. F., & Wintersperger, B. J. (2010) · Der Radiologe · doi:10.1007/s00117-010-1987-8 · Cited by 8
Magnetic resonance image restoration via dictionary learning under spatially adaptive constraints
Wang, S., Xia, Y., Dong, P., Feng, D. D., Luo, J., & Huang, Q. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610429 · Cited by 8
Wu, M., Mulder, H. T., Zur, Y., Lechner-Greite, S. M., Menzel, M. I., Paulides, M. M., van Rhoon, G. C., & Haase, A. (2018) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-018-0725-5 · Cited by 8
Isointense model for the evaluation of tumor-specific MRI contrast agents
Button, T. M., & Fiel, R. J. (1988) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(88)90402-x · Cited by 8
Eis, M., & Hoehn‐Berlage, M. (1994) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/bf01753063 · Cited by 8
Giovannetti, G., Flori, A., & Frijia, F. (2023) · Sensors · doi:10.3390/s23125586 · Cited by 7
Giovannetti, G., Tiberi, G., Tosetti, M., Monorchio, A., & Fontana, N. (2018) · Measurement · doi:10.1016/j.measurement.2018.07.060 · Cited by 7
Jokivuolle, M., Mahmood, F., Madsen, K. H., Harbo, F. S. G., Johnsen, L., & Lundell, H. (2024) · Medical Physics · doi:10.1002/mp.17453 · Cited by 7
Monitoring local heating around an interventional MRI antenna with RF radiometry
Ertürk, M. A., El‐Sharkawy, A. M., & Bottomley, P. A. (2015) · Medical Physics · doi:10.1118/1.4907960 · Cited by 7
On the parameter estimation problem of magnetic resonance advection imaging
Hubmer, S., Neubauer, A., Ramlau, R., & Voss, H. U. (2018) · Inverse Problems and Imaging · doi:10.3934/ipi.2018007 · Cited by 7
Metadata
- Authors
- Edelstein, W. A., Glover, G. H., Hardy, C. J., & Redington, R. W.
- Affiliations
- General Electric (United States) (US)
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1986-08
- Volume
- 3
- Issue
- 4
- Pages
- 604-618
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2032038095
- Cited by
- 758
- References
- 13
- Citations by year
- 2026: 16 · 2025: 19 · 2024: 21 · 2023: 25 · 2022: 22 · 2021: 18 · 2020: 35 · 2019: 25 · 2018: 22 · 2017: 25 · 2016: 35 · 2015: 25 · 2014: 31 · 2013: 20 · 2012: 27
- FWCI
- 6.33
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Magnetic Resonance in Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
- Keywords
- magnetic resonance imaging, thermal noise, receiving antenna, pixel size, static magnetic field dependence
- MeSH terms
- Abdomen, Biometry, Biophysics, Head, Humans, Magnetic Resonance Spectroscopy, Pelvis, Biophysical Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.