Localized Proton NMR spectroscopy using stimulated echoes: Applications to human skeletal muscle in vivo
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Localized proton NMR spectroscopy using stimulated echoes (STEAM) has been used to study metabolites in different proximal skeletal muscles of normal volunteers at rest. Single scan water‐suppressed proton NMR spectra obtained at 1.5 and 2.0 T (Siemens Magnetom) from a 64‐ml volume‐of‐interest (VOI) yield resonances due to triglycerides, phosphocreatine plus a minor contribution from creatine, and betaines comprising carnitine and choline‐containing compounds. The observation of the pH‐dependent resonances of carnosine required multiple acquisitions and echo times as short as 20 ms. T1 and T2 relaxation times of muscle metabolites were obtained by varying the repetition time and echo time of the STEAM sequence, respectively. Although rather long T2 values such as 180 ms for (phospho‐) creatine correspond to natural resonance line widths of only 2 Hz, the observed line widths of typically 10‐12 Hz are entirely determined by the short T2 relaxation times (25‐30 ms) of the water protons used for shimming. The spectroscopic results from 24 muscle studies on 17 young male volunteers show remarkable intra‐ and interindividual differences in the absolute signal intensities of mobile lipids. Further metabolic variations were observed for the relative concentrations of betaines (by a factor of 2) and carnosine (by a factor of 3) when total creatine is assumed to be constant. © 1991 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intramuscular substrate utilization during prolonged exercise
Esséen, B. (1977) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1977.tb38183.x · Cited by 133
Cited by
Measurement of intracellular triglyceride stores by H spectroscopy: validation in vivo
Szczepaniak, L. S., Babcock, E. E., Schick, F., Dobbins, R. L., Garg, A., Burns, D. K., McGarry, J. D., & Stein, D. T. (1999) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1999.276.5.e977 · Cited by 688
Clinical Proton MR Spectroscopy in Central Nervous System Disorders
Öz, G., Alger, J. R., Barker, P. B., Bartha, R., Bizzi, A., Boesch, C., Bolan, P. J., Brindle, K. M., Cudalbu, C., Dinçer, A., et al. (2014) · Radiology · doi:10.1148/radiol.13130531 · Cited by 660
Self-citationMolecular basis of skeletal muscle plasticity-from gene to form and function
Flück, M., & Hoppeler, H. (2003) · Reviews of Physiology, Biochemistry and Pharmacology · doi:10.1007/s10254-002-0004-7 · Cited by 480
Methodological consensus on clinical proton MRS of the brain: Review and recommendations
Wilson, M., Andronesi, O., Barker, P. B., Bartha, R., Bizzi, A., Bolan, P. J., Brindle, K. M., Choi, I., Cudalbu, C., Dydak, U., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27742 · Cited by 470
Boesch, C., Slotboom, J., Hoppeler, H., & Kreis, R. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370403 · Cited by 421
Imaging of Brain Tumors: MR Spectroscopy and Metabolic Imaging
Horská, A., & Barker, P. B. (2010) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2010.04.003 · Cited by 356
Schick, F., Eismann, B., Jung, W., Bongers, H., Bunse, M., & Lutz, O. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290203 · Cited by 349
Quantification of liver fat using magnetic resonance spectroscopy
Thomsen, C., Becker, U., Winkler, K., Christoffersen, P., Jensen, M., & Henriksen, O. (1994) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)92543-7 · Cited by 332
Carnosine: Its properties, functions and potential therapeutic applications
Quinn, P. J., Boldyrev, A. A., & Formazuyk, V. E. (1992) · Molecular Aspects of Medicine · doi:10.1016/0098-2997(92)90006-l · Cited by 306
Recent advances in parallel imaging for MRI
Hamilton, J., Franson, D., & Seiberlich, N. (2017) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2017.04.002 · Cited by 251
Effect of PRESS and STEAM sequences on magnetic resonance spectroscopic liver fat quantification
Hamilton, G., Middleton, M. S., Bydder, M., Yokoo, T., Schwimmer, J. B., Kono, Y., Patton, H. M., Lavine, J. E., & Sirlin, C. B. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21809 · Cited by 215
Big GABA: Edited MR spectroscopy at 24 research sites
Mikkelsen, M., Barker, P. B., Bhattacharyya, P. K., Brix, M. K., Buur, P. F., Cecil, K. M., Chan, K. L., Chen, D. Y.-T., Craven, A. R., Cuypers, K., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.021 · Cited by 183
Non-invasive magnetic-resonance detection of creatine depletion in non-viable infarcted myocardium
Bottomley, P. A., & Weiss, R. G. (1998) · The Lancet · doi:10.1016/s0140-6736(97)06402-7 · Cited by 170
Quantitative localized 1H MR spectroscopy for clinical use
Kreis, R. (1997) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/s0079-6565(97)00014-9 · Cited by 166
Meyerhoff, D. J., Mon, A., Metzler, T., & Neylan, T. C. (2014) · Sleep · doi:10.5665/sleep.3654 · Cited by 133
Fasting for 72 h increases intramyocellular lipid content in nondiabetic, physically fit men
Stannard, S. R., Thompson, M. W., Fairbairn, K., Huard, B., Sachinwalla, T., & Thompson, C. H. (2002) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00108.2002 · Cited by 108
“Signal amplitude of water, carnitine-N(CH3)3, creatine-CH3, EMCL-(CH2)n, and IMCL-(CH2)n were corrected using appropriate T1 relaxation times available in the literature for leg skeletal muscle [H2O, 1,100 ms (37); IMCL-(CH2)n, 300 ms; EMCL-(CH2)n, 300 ms; creatine-CH3, 1,350 ms (10)] and the T2 relaxation times obtai…”
MethodRico‐Sanz, J., Hajnal, J. V., Thomas, E. L., Mierisová, Ŝ., Ala‐Korpela, M., & Bell, J. D. (1998) · The Journal of Physiology · doi:10.1111/j.1469-7793.1998.615bk.x · Cited by 88
“…IT and ET was as determined by Schick et al. (1993), for protons from Cho as the average of values measured by Bruhn et al. (1991) and Schick et al. (1993), and for protons from TCr and water as the average of values reported by Bruhn et al. (1991), Schick et al. (1993) and Bottomley et al. (1997).”
Method
Metadata
- Authors
- Bruhn, H., Frahm, J., Gyngell, M. L., Merboldt, K. D., Hänicke, W., & Sauter, R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1991-01
- Volume
- 17
- Issue
- 1
- Pages
- 82-94
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1989252074
- Cited by
- 149
- References
- 1
- FWCI
- 4.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.