The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Identification of vascular structures as a major source of signal contrast in high resolution 2D and 3D functional activation imaging of the motor cortex at l.5T preliminary results
Abstract
We have measured the T2* signal response associated with cortical activation due to finger motion at 1.5 Tesla. Both thin slice 2D and 3D images show signal intensity changes which vary from 2% to 32% depending on volunteer, echo time, slice thickness, and in‐plane resolution. The largest signal change occurred for the thinnest slices and highest resolution (2 mm 3). This is consistent with reducing partial volume effects and a simple difference in phase between the intravascular signal and surrounding parenchyma. No inflow enhancement was seen on the 2D or 3D scans, confirming the nature of the signal difference for this approach was due to local field in‐homogeneity effects. Using 3D imaging, multiple effects can be seen simultaneously. With a 3D MRA method, it was possible to locate the vessel that was the source of the T2* behavior; it was in each case a vein on the surface of the cortical parenchyma.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Indeed, activity in the AIC is a common feature in studies of cognitive control and inhibitory processing [7, 46–50] and reward sensitivity [8, 9].”
From The role of the anterior insula in adolescent decision making (2014) · cites this paper as [50]
Citations
Cites
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
Ogawa, S., Lee, T., Nayak, A. S., & Glynn, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140108 · Cited by 2,269
Nonoxidative Glucose Consumption During Focal Physiologic Neural Activity
Fox, P. T., Raichle, M. E., Mintun, M. A., & Dence, C. (1988) · Science · doi:10.1126/science.3260686 · Cited by 1,796
Functional mapping of the human visual cortex at 4 and 1.5 tesla using deoxygenation contrast EPI
Turner, R., Jezzard, P., Wen, H. H., Kwong, K. K., Bihan, D. L., Zeffiro, T. A., & Balaban, R. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290221 · Cited by 454
Dynamic MR imaging of human brain oxygenation during rest and photic stimulation
Frahm, J., Bruhn, H., Merboldt, K., & Hänicke, W. (1992) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880020505 · Cited by 385
Functional imaging of human motor cortex at high magnetic field
Kim, S., Ashe, J., Georgopoulos, A. P., Merkle, H., Ellermann, J., Menon, R. S., Ogawa, S., & Uǧurbil, K. (1993) · Journal of Neurophysiology · doi:10.1152/jn.1993.69.1.297 · Cited by 375
Functional MRI of human brain activation at high spatial resolution
Frahm, J., Merboldt, K., & Hänicke, W. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290126 · Cited by 350
Experimental Researches in Electricity
Faraday, M. (2012) · Cambridge University Press eBooks · doi:10.1017/cbo9781139383158 · Cited by 291
Basic physics of MR contrast agents and maximization of image contrast
Hendrick, R. E., & Haacke, E. M. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030126 · Cited by 149
Self-citationReduction of T2* dephasing in gradient field-echo imaging.
Haacke, E. M., Tkach, J. A., & Parrish, T. B. (1989) · Radiology · doi:10.1148/radiology.170.2.2911669 · Cited by 134
Self-citation
Flagged first, then by citations
Research works printed but not linked: 3
- Selwood P. W., 1943, Magnetochemistry, 163
- Kwong K. K., 1992, J. Magn. Reson. Imaging, 2, 76
- Bandettini P. A., 1992, J. Magn. Reson. Imaging, 2, 76
Cited by
Sorted by citations
Items 201–300 of 387
Çavuşoğlu, M., Bartels, A., Yesilyurt, B., & Uludaǧ, K. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.056 · Cited by 28
Dependence of gradient‐echo and spin‐echo BOLD fMRI at 4 T on diffusion weighting
Michelich, C. R., Song, A. W., & MacFall, J. R. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1035 · Cited by 25
DIFFUSION AND PERFUSION IMAGING TECHNIQUES
Patel, M. R., Siewert, B., Warach, S. J., & Edelman, R. R. (1995) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/s1064-9689(21)00254-3 · Cited by 25
Kuppusamy, K., Lin, W., & Haacke, E. M. (1997) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(96)00338-4 · Cited by 25
Self-citationPirotte, B. J. M., Neugroschl, C., Metens, T., Wikler, D., Denolin, V., Voordecker, P., Joffroy, A., Massager, N., Brotchi, J., Levivier, M., et al. (2005) · PubMed Central · Cited by 24
Synchronized detection of minute electrical currents with MRI using Lorentz effect imaging
Truong, T., Wilbur, J. L., & Song, A. W. (2005) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2005.11.012 · Cited by 24
Manganotti, P., Zanette, G., Beltramello, A., Puppini, G., Miniussi, C., Maravita, A., Santorum, E., Marzi, C. A., Fiaschi, A., & Bernardina, B. D. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00045-5 · Cited by 24
Bydder, G. M. (1995) · British Journal of Radiology · doi:10.1259/0007-1285-68-816-1271 · Cited by 24
Lai, S., Wang, J., & Jahng, G. (2001) · NMR in Biomedicine · doi:10.1002/nbm.738 · Cited by 23
Self-citationPalmer, J. T., de Crespigny, A. J., Williams, S., Busch, E. W., & van Bruggen, N. (1999) · NeuroImage · doi:10.1006/nimg.1998.0415 · Cited by 23
Pushing the spatio-temporal limits of MRI and fMRI
Yacoub, E. S., & Wald, L. L. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.11.034 · Cited by 22
Beltramello, A., Cerini, R., Puppini, G., El-Dalati, G., Viola, S., Martone, E., Cordopatri, D., Manfredi, M., Aglioti, S. M., & Tassinari, G. (1998) · Neurological Sciences · doi:10.1007/bf00713853 · Cited by 22
Stenger, V. A., Noll, D. C., & Boada, F. E. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400320 · Cited by 22
Functional Magnetic Resonance Neuroimaging Data Acquisition Techniques
Duyn, J. H., Yang, Y., Frank, J. A., Mattay, V. S., & Hou, L. (1996) · NeuroImage · doi:10.1006/nimg.1996.0057 · Cited by 22
Mapping of the cerebral response to hypoxia measured using graded asymmetric spin echo EPI
Houston, G. C., Papadakis, N. G., Carpenter, T. A., Hall, L. D., Mukherjee, B., James, M. F., & Huang, C. L.-H. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(00)00196-x · Cited by 22
Massive Modulation of Brain Areas After Mechanical Pain Stimulation: A Time-Resolved fMRI Study
Cauda, F., Costa, T., Diano, M., Sacco, K., Duca, S., Geminiani, G. C., & Torta, D. M. E. (2013) · Cerebral Cortex · doi:10.1093/cercor/bht153 · Cited by 23
Lu, H., Basso, G., Serences, J. T., Yantis, S., Golay, X., & van Zijl, P. C. M. (2005) · Neuroreport · doi:10.1097/01.wnr.0000181580.18636.ee · Cited by 21
Pouratian, N., Sheth, S. A., Bookheimer, S. Y., Martin, N. A., & Toga, A. W. (2003) · Neurosurgical FOCUS · doi:10.3171/foc.2003.15.1.2 · Cited by 21
Spatial localization and resolution of BOLD fMRI
Zarahn, E. (2001) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(00)00198-7 · Cited by 21
Ultra-high field parallel imaging of the superior parietal lobule during mental maze solving
Jerde, T. A., Lewis, S. M., Goerke, U., Gourtzelidis, P., Tzagarakis, C., Lynch, J. K., Moeller, S., de Moortele, P. V., Adriany, G., Trangle, J., et al. (2008) · Experimental Brain Research · doi:10.1007/s00221-008-1318-8 · Cited by 20
BOLD fMRI using a modified HASTE sequence
Ye, Y., Zhuo, Y., Xue, R., & Zhou, X. J. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.07.044 · Cited by 20
Pouratian, N., Bookheimer, S. Y., Rex, D., Martin, N. A., & Toga, A. W. (2002) · Neurosurgical FOCUS · doi:10.3171/foc.2002.13.4.5 · Cited by 19
Lai, S., Reichenbach, J. R., & Haacke, E. M. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360518 · Cited by 19
Self-citationQuantifying effective magnetic moments of narrow cylindrical objects in MRI
Cheng, Y. N., Hsieh, C., Neelavalli, J., & Haacke, E. M. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/22/018 · Cited by 18
Self-citationSpatial and temporal resolution in fMRI
Menon, R. S., & Goodyear, B. G. (2001) · doi:10.1093/acprof:oso/9780192630711.003.0007 · Cited by 18
Correction for head movements in multi-slice EPI functional MRI
Singh, M., Al-Dayeh, L., Patel, P., Kim, T., Guclu, C., & Nalcioglu, O. (1998) · IEEE Transactions on Nuclear Science · doi:10.1109/23.708332 · Cited by 18
Brain functional modeling, what do we measure with fMRI data?
de Marco, G., Devauchelle, B., & Berquin, P. C. (2009) · Neuroscience Research · doi:10.1016/j.neures.2009.01.015 · Cited by 17
Truong, T., & Song, A. W. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.04.045 · Cited by 17
Kim, S., & Bandettini, P. A. (2010) · Springer eBooks · doi:10.1007/978-1-4419-1329-6_1 · Cited by 17
The effects of K-space data undersampling and discontinuities in keyhole functional MRI
Xiong, J., Fox, P. T., & Gao, J. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)00147-7 · Cited by 17
Du, W., Karczmar, G. S., Uftring, S. J., & Du, Y. P. (2005) · NMR in Biomedicine · doi:10.1002/nbm.952 · Cited by 17
Functional Magnetic Resonance Imaging of Primary Visual Processing Using a 1.0 Tesla Scanner
Lundervold, A., Ersland, L., Gjesdal, K., Smievoll, A. I., Tillung, T., Sundberg, H., & Hugdahl, K. (1995) · International Journal of Neuroscience · doi:10.3109/00207459509004883 · Cited by 17
An improved method for susceptibility and radius quantification of cylindrical objects from MRI
Hsieh, C., Cheng, Y. N., Neelavalli, J., Haacke, E. M., & Stafford, R. J. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2015.01.004 · Cited by 16
Self-citationKalcher, K., Boubela, R. N., Huf, W., Našel, C., & Moser, E. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00472 · Cited by 14
Harshbarger, T. B., & Song, A. W. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20293 · Cited by 16
Apparent water diffusion measurements in electrically stimulated neural tissue
Gulani, V., Iwamoto, G. A., & Lauterbur, P. C. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199902)41:2 · Cited by 22
Localizing the central sulcus by functional magnetic resonance imaging and magnetoencephalography
Shimizu, H., Nakasato, N., Mizoi, K., & Yoshimoto, T. (1997) · Clinical Neurology and Neurosurgery · doi:10.1016/s0303-8467(97)00096-6 · Cited by 16
Singh, M., Kim, H., Kim, T., & Khosia, D. (1994) · IEEE Transactions on Nuclear Science · doi:10.1109/23.322990 · Cited by 16
Vizioli, L., Martino, F. D., Petro, L. S., Kersten, D., Uǧurbil, K., Yacoub, E. S., & Muckli, L. F. (2020) · Scientific Reports · doi:10.1038/s41598-020-64044-x · Cited by 16
Spatial and Temporal Characteristics of Physiological Noise in fMRI at 3T
Liu, C. J., Miki, A., Hulvershorn, J., Bloy, L., Gualtieri, E., Liu, G. T., LEIGH, J. S. J., Haselgrove, J. C., & Elliott, M. A. (2006) · Academic Radiology · doi:10.1016/j.acra.2005.10.018 · Cited by 15
A Functional Magnetic Resonance Imaging Technique Based on Nulling Extravascular Gray Matter Signal
Shen, Y., Kauppinen, R. A., Vidyasagar, R., & Golay, X. (2008) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2008.96 · Cited by 14
FMRI of the Emotions: Towards an Improved Understanding of Amygdala Function
Robinson, S., Hoheisel, B., Windischberger, C., Habel, U., Lanzenberger, R. R., & Moser, E. (2005) · Current Medical Imaging Formerly Current Medical Imaging Reviews · doi:10.2174/1573405054038717 · Cited by 14
Spatial Selectivity of BOLD Contrast: Effects In and Around Draining Veins
Lai, S., Glover, G. H., & Haacke, E. M. (2000) · Medical radiology · doi:10.1007/978-3-642-58716-0_20 · Cited by 14
Self-citationHigh Magnetic Fields for Imaging Cerebral Morphology, Function, and Biochemistry
Uǧurbil, K., Adriany, G., Akgun, C. E., Andersen, P. M., Chen, W., Garwood, M., Rolf Gruetter, A., Henry, P., Marjańska, M., Moeller, S., et al. (2006) · Biological magnetic resonance · doi:10.1007/978-0-387-49648-1_10 · Cited by 13
Song, A. W., & Gangstead, S. L. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/1/005 · Cited by 13
Yamada, K., Naruse, S., Nakajima, K., Furuya, S., Morishita, H., Kizu, O., Maeda, T., Takeo, K., & Shimizu, K. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070215 · Cited by 13
Menon, R. S., Ogawa, S., & Uǧurbil, K. (1995) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.1850060211 · Cited by 13
Zheng, J., Ehrhardt, J. C., Cizadlo, T., & Yuh, W. T. C. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070511 · Cited by 13
Echo-Planar Magnetic Resonance Imaging of Human Brain Activation
Bandettini, P. A., & Wong, E. C. (1998) · Springer eBooks · doi:10.1007/978-3-642-80443-4_15 · Cited by 13
Rumeur, É. L., Michèle Allard, A., Poiseau, É., & Jannin, P. (2000) · Journal of neurosurgery · doi:10.3171/jns.2000.93.3.0427 · Cited by 12
Barth, M., Windischberger, C., Klarhöfer, M., & Moser, E. (2001) · NMR in Biomedicine · doi:10.1002/nbm.737 · Cited by 12
Kraut, M. A., Marenco, S., Soher, B. J., Wong, D. F., & Bryan, R. N. (1995) · PubMed Central · Cited by 12
Blue blood or black blood: R1 effects in gradient-echo echo-planar functional neuroimaging
Righini, A., Pierpaoli, C. M., Barnett, A. S., Waks, E., & Alger, J. R. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)00136-q · Cited by 12
Gomez, D. E. P., Polimeni, J. R., & Lewis, L. D. (2024) · Imaging Neuroscience · doi:10.1162/imag_a_00399 · Cited by 11
Brain imaging investigation of chemotherapy-induced neurocognitive changes
McDonald, B. C., Saykin, A. J., & Ahles, T. A. (2008) · Cambridge University Press eBooks · doi:10.1017/cbo9780511545900.004 · Cited by 11
Logarithmic transformation for high-field BOLD fMRI data
Lewis, S. M., Jerde, T. A., Tzagarakis, C., Gourtzelidis, P., Georgopoulos, M.-A., Tsekos, N. V., Amirikian, B. R., Kim, S., Uǧurbil, K., & Georgopoulos, A. P. (2005) · Experimental Brain Research · doi:10.1007/s00221-005-2336-4 · Cited by 11
FUNCTIONAL MR IMAGING OF PERCEPTUAL AND COGNITIVE FUNCTIONS
Latchaw, R. E., Uǧurbil, K., & Hu, X. P. (1995) · Neuroimaging Clinics of North America · doi:10.1016/s1052-5149(25)00290-4 · Cited by 11
Gradient Echo and Spin Echo Methods for Functional MRI
Kennan, R. P. (2000) · Medical radiology · doi:10.1007/978-3-642-58716-0_12 · Cited by 11
Field Strength Dependence of Functional MRI Signals
Gati, J. S., Menon, R. S., & Rutt, B. K. (2000) · Medical radiology · doi:10.1007/978-3-642-58716-0_25 · Cited by 11
Spatial Resolution of BOLD and Other fMRI Techniques
Kim, S.-G., Lee, S. P., Silva, A. C., & Goodyear, B. G. (2000) · Medical radiology · doi:10.1007/978-3-642-58716-0_18 · Cited by 11
Functional Imaging of the Brain by Nuclear Magnetic Resonance
Ellermann, J., Garwood, M., Hendrich, K. S., Hinke, R. M., Hu, X. P., Kim, S., Menon, R. S., Merkle, H., Ogawa, S., & Uǧurbil, K. (1994) · Elsevier eBooks · doi:10.1016/b978-0-12-283980-1.50013-2 · Cited by 11
Mazaheri, Y., Biswal, B. B., Ward, B. D., & Hyde, J. S. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.03.051 · Cited by 10
Vu, A. T., & Gallant, J. L. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00411 · Cited by 10
Dipasquale, O., Cohen, A. D., Martins, D., Zelaya, F. O., Turkheimer, F., Veronese, M., Mehta, M. A., Williams, S., Yang, B., Banerjee, S., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-38573-0 · Cited by 10
Susceptibility and size quantification of small human veins from an MRI method
Hsieh, C., Cheng, Y. N., Xie, H., Haacke, E. M., & Neelavalli, J. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2015.07.008 · Cited by 10
Self-citationSingle‐shot ADC imaging for fMRI
Song, A. W., Guo, H., & Truong, T. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21135 · Cited by 10
Functional Magnetic Resonance Imaging of the Somatosensory Cortex
Mueller, W. M., Yetkin, F. Z., & Haughton, V. M. (1997) · Neurosurgery Clinics of North America · doi:10.1016/s1042-3680(18)30310-3 · Cited by 10
Separation of veins from activated brain tissue in functional magnetic resonance images at 1.5T
Singh, M., Kim, T., Kim, H., & Khosla, D. (1995) · IEEE Transactions on Nuclear Science · doi:10.1109/23.467861 · Cited by 10
Effects of large vessels in functional magnetic resonance imaging at 1.5T
Duyn, J. H., Frank, J. A., Ramsey, N. F., Mattay, V. S., Sexton, R. H., Tallent, K. A., Weinberger, D. R., MOONEN, C. T. W., & van Gelderen, P. (1995) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.1850060216 · Cited by 9
Functional MR Imaging of the Human Brain Using FLASH: Influence of Various Imaging Parameters
Preibisch, C., & Haase, A. (1999) · Journal of Magnetic Resonance · doi:10.1006/jmre.1999.1838 · Cited by 9
Fall, S., & de Marco, G. (2007) · Biological Cybernetics · doi:10.1007/s00422-007-0198-5 · Cited by 9
Superior cortical venous anatomy for endovascular device implantation: a systematic review
Brannigan, J., McClanahan, A. J., Hui, F. K., Fargen, K. M., Pinter, N. K., & Oxley, T. J. (2024) · Journal of NeuroInterventional Surgery · doi:10.1136/jnis-2023-021434 · Cited by 11
Microvascular functional MR angiography with ultra‐high‐field 7 t MRI: Comparison with BOLD fMRI
Cho, Z., Kang, C., Park, C., Hong, S., Kim, S., Oh, S., & Kim, Y.-B. (2012) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.22008 · Cited by 8
Mapping plasticity in the forepaw digit barrel subfield of rat brains using functional MRI
Weng, J., Chuang, K., Goloshevsky, A. G., Dodd, S. J., & Sharer, K. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.08.046 · Cited by 8
Structural impacts on the timing and amplitude of the negative BOLD response
Provencher, D., Bizeau, A., Gilbert, G., Bérubé-Lauzière, Y., & Whittingstall, K. (2017) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2017.09.007 · Cited by 7
Functional MRI Signal Decrease at the Onset of Stimulation
Hu, X. P., Yacoub, E. S., Le, T. H., Cohen, E. R., & Uǧurbil, K. (2000) · Medical radiology · doi:10.1007/978-3-642-58716-0_22 · Cited by 8
The impact of vascular factors on language localization in the superior temporal sulcus
Wilson, S. M. (2014) · Human Brain Mapping · doi:10.1002/hbm.22457 · Cited by 7
Activation detection in fMRI data via multiscale singularity detection
Ralf Mekle, A., Laine, A. F., Perera, G. M., & DeLaPaz, R. L. (2000) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.408651 · Cited by 7
fMRI und direkte elektrische kortikale Stimulation
Krings, T., Krombach, G. A., Reul, J., Spetzger, U., Roessler, F. C., Foltys, H., Gilsbach, J. M., & Thron, A. K. (1998) · Clinical Neuroradiology · doi:10.1007/bf03043439 · Cited by 7
EEG–fMRI in Adults with Focal Epilepsy
Walker, M. C., Chaudhary, U. J., & Lemieux, L. (2009) · Springer eBooks · doi:10.1007/978-3-540-87919-0_15 · Cited by 6
Rossi, C., Boss, A., Donati, O. F., Luechinger, R., Kollias, S. S., Valavanis, A., Hodler, J., & Nanz, D. (2012) · NMR in Biomedicine · doi:10.1002/nbm.2775 · Cited by 6
Temporal resolving power of perfusion- and BOLD-based event-related functional MRI
Su, F. C., Chu, T.-C., Wai, Y., Wan, Y., & Liu, H. (2003) · Medical Physics · doi:10.1118/1.1634480 · Cited by 6
Haacke, E. M., Lin, W., Hu, X. P., & Thulborn, K. R. (2001) · NMR in Biomedicine · doi:10.1002/nbm.734 · Cited by 6
Self-citationPerfusion MR imaging: Evolution from initial development to functional studies
Kim, S. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.015 · Cited by 6
BASIC CONCEPTS OF FUNCTIONAL MAGNETIC RESONANCE IMAGING AND ARTERIOVENOUS MALFORMATIONS
Turski, P. A., Cordes, D., Mock, B., Wendt, G. J., Sorenson, J. A., Fitzurka-Quigley, M., Strother, C. M., & Dempsey, R. J. (1998) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/s1064-9689(21)00484-0 · Cited by 6
PRESTO, a Rapid 3D Approach for Functional MRI of Human Brain
MOONEN, C. T. W., van Gelderen, P., Ramsey, N. F., Liu, G., Duyn, J. H., Frank, J., & Weinberger, D. R. (1996) · Springer eBooks · doi:10.1007/978-88-470-2194-5_20 · Cited by 6
Gaxiola‐Valdez, I., & Goodyear, B. G. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.05.002 · Cited by 5
Habecker, E. L., Daniels, M. A., & Renshaw, P. F. (2009) · Neuromethods · doi:10.1007/978-1-60327-919-2_21 · Cited by 5
Kim, S., & Bandettini, P. A. (2006) · Springer eBooks · doi:10.1007/0-387-34665-1_1 · Cited by 5
Fellner, C., Schlaier, J. R., Müller, E., & Fellner, F. A. (1998) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)00140-4 · Cited by 5
In vivo magnetic resonance methods in pharmaceutical research: current status and perspectives
Rudin, M., Beckmann, N., Pórszász, R., Reese, T., Bochelen, D., & Sauter, A. (1999) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199904)12:2 · Cited by 98
Cross-correlation technique to identify activated pixels in a three-condition fMRI task
Singh, M., Al-Dayeh, J. J. L., Kim, T., & Colletti, P. M. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.775573 · Cited by 5
Functional brain imaging with a standard 1.5-T magnetic resonance imaging system
Jack, C. R., Lee, C. C., & Riederer, S. J. (1995) · Academic Radiology · doi:10.1016/s1076-6332(05)80074-1 · Cited by 5
Magnetic resonance functional imaging of the brain at 4 t
Turner, R., & Jezzard, P. (1994) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/bf01705234 · Cited by 5
Magnetic Resonance Assessment of Myocardial Oxygenation
Dharmakumar, R., & Li, D. (2010) · Elsevier eBooks · doi:10.1016/b978-0-443-06686-3.00042-4 · Cited by 4
Self-citationRamadan, D., Mueller, S., Stirnberg, R., Bosch, D., Ehses, P., Scheffler, K., & Bause, J. (2024) · Imaging Neuroscience · doi:10.1162/imag_a_00435 · Cited by 4
The characterization of dynamic susceptibility effects
Weisskoff, R. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.019 · Cited by 4
Yacoub, E. S., Harel, N., & Shmuel, A. (2015) · Biological magnetic resonance · doi:10.1007/978-1-4899-7591-1_26 · Cited by 4
Schlaier, J. R., Fellner, C., Schwerdtner, J., Seitz, J., & Brawanski, A. T. (1999) · Computerized Medical Imaging and Graphics · doi:10.1016/s0895-6111(99)00023-3 · Cited by 4
Automatic vessel segmentation using active contours in cine phase contrast flow measurements
Kozerke, S., Botnar, R. M., Oyre, S., Scheidegger, M. B., Pedersen, E. M., & Boesiger, P. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199907)10:1 · Cited by 98
Metadata
- Authors
- Lai, S., Hopkins, A. L., Haacke, E. M., Li, D., Wasserman, B. A., Buckley, P., Friedman, L., Meltzer, H., Hedera, P., & Friedland, R.
- Affiliations
- Case Western Reserve University (US)
- Corresponding author
- Haacke, E. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1993-09
- Volume
- 30
- Issue
- 3
- Pages
- 387-392
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2013713875
- Cited by
- 390
- References
- 12
- Citations by year
- 2025: 2 · 2024: 6 · 2023: 3 · 2022: 2 · 2021: 5 · 2020: 2 · 2019: 2 · 2018: 2 · 2017: 7 · 2016: 4 · 2015: 8 · 2014: 8 · 2013: 3 · 2012: 13
- FWCI
- 27.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Magnetic Resonance in Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute on Aging (NIA AG08012)
- National Institute of Mental Health (NIMH 41684)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Life Sciences › Neuroscience › Cognitive Neuroscience › Functional Brain Connectivity Studies
- Keywords
- vascular architecture, motor cortex activation, finger movement, 1.5 Tesla, partial volume effect, cerebral veins, cerebral blood volume, three-dimensional MR angiography
- MeSH terms
- Brain, Cerebrovascular Circulation, Fingers, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Motor Cortex, Movement, Signal Processing, Computer-Assisted, Time Factors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review