The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Identification of vascular structures as a major source of signal contrast in high resolution 2D and 3D functional activation imaging of the motor cortex at l.5T preliminary results
Abstract
We have measured the T2* signal response associated with cortical activation due to finger motion at 1.5 Tesla. Both thin slice 2D and 3D images show signal intensity changes which vary from 2% to 32% depending on volunteer, echo time, slice thickness, and in‐plane resolution. The largest signal change occurred for the thinnest slices and highest resolution (2 mm 3). This is consistent with reducing partial volume effects and a simple difference in phase between the intravascular signal and surrounding parenchyma. No inflow enhancement was seen on the 2D or 3D scans, confirming the nature of the signal difference for this approach was due to local field in‐homogeneity effects. Using 3D imaging, multiple effects can be seen simultaneously. With a 3D MRA method, it was possible to locate the vessel that was the source of the T2* behavior; it was in each case a vein on the surface of the cortical parenchyma.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Indeed, activity in the AIC is a common feature in studies of cognitive control and inhibitory processing [7, 46–50] and reward sensitivity [8, 9].”
From The role of the anterior insula in adolescent decision making (2014) · cites this paper as [50]
Citations
Cites
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
Ogawa, S., Lee, T., Nayak, A. S., & Glynn, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140108 · Cited by 2,269
Nonoxidative Glucose Consumption During Focal Physiologic Neural Activity
Fox, P. T., Raichle, M. E., Mintun, M. A., & Dence, C. (1988) · Science · doi:10.1126/science.3260686 · Cited by 1,796
Functional mapping of the human visual cortex at 4 and 1.5 tesla using deoxygenation contrast EPI
Turner, R., Jezzard, P., Wen, H. H., Kwong, K. K., Bihan, D. L., Zeffiro, T. A., & Balaban, R. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290221 · Cited by 454
Dynamic MR imaging of human brain oxygenation during rest and photic stimulation
Frahm, J., Bruhn, H., Merboldt, K., & Hänicke, W. (1992) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880020505 · Cited by 385
Functional imaging of human motor cortex at high magnetic field
Kim, S., Ashe, J., Georgopoulos, A. P., Merkle, H., Ellermann, J., Menon, R. S., Ogawa, S., & Uǧurbil, K. (1993) · Journal of Neurophysiology · doi:10.1152/jn.1993.69.1.297 · Cited by 375
Functional MRI of human brain activation at high spatial resolution
Frahm, J., Merboldt, K., & Hänicke, W. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290126 · Cited by 350
Experimental Researches in Electricity
Faraday, M. (2012) · Cambridge University Press eBooks · doi:10.1017/cbo9781139383158 · Cited by 291
Basic physics of MR contrast agents and maximization of image contrast
Hendrick, R. E., & Haacke, E. M. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030126 · Cited by 149
Self-citationReduction of T2* dephasing in gradient field-echo imaging.
Haacke, E. M., Tkach, J. A., & Parrish, T. B. (1989) · Radiology · doi:10.1148/radiology.170.2.2911669 · Cited by 134
Self-citation
Research works printed but not linked: 3
- Selwood P. W., 1943, Magnetochemistry, 163
- Kwong K. K., 1992, J. Magn. Reson. Imaging, 2, 76
- Bandettini P. A., 1992, J. Magn. Reson. Imaging, 2, 76
Cited by
Sorted by citations
Items 101–200 of 387
Blockwise processing applied to brain microvascular network study
Fouard, C., Malandain, G., Prohaska, S., & Westerhoff, M. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.880670 · Cited by 80
Wu, D. H., Lewin, J. S., & Duerk, J. L. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070219 · Cited by 80
Functional Mapping of the Human Somatosensory Cortex with Echo‐Planar MRI
Sakai, K. L., Watanabe, E., Onodera, Y., Itagaki, H., Yamamoto, E., Koizumi, H., & Miyashita, Y. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330521 · Cited by 80
The spatial extent of the BOLD response
Saad, Z. S., Ropella, K. M., DeYoe, E. A., & Bandettini, P. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00016-8 · Cited by 78
Simultaneous 3-T fMRI and high-density recording of human auditory evoked potentials
Scarff, C. J., Reynolds, A., Goodyear, B. G., Ponton, C. W., Dort, J. C., & Eggermont, J. J. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.035 · Cited by 79
Anxiety, respiration, and cerebral blood flow: implications for functional brain imaging
Giardino, N. D., Friedman, S. D., & Dager, S. R. (2007) · Comprehensive Psychiatry · doi:10.1016/j.comppsych.2006.11.001 · Cited by 83
Derrfuß, J., Braß, M., von Cramon, D. Y., Lohmann, G., & Amunts, K. (2007) · Human Brain Mapping · doi:10.1002/hbm.20501 · Cited by 78
Robot-aided functional imaging: Application to a motor learning study
Krebs, H. I., Brashers-Krug, T. M., Rauch, S. L., Savage, C. R., Hogan, N., Rubin, R. H., Fischman, A. J., & Alpert, N. M. (1998) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1998)6:1 · Cited by 117
Improved spatial localization of post-stimulus BOLD undershoot relative to positive BOLD
Zhao, F., Jin, T., Wang, P., & Kim, S. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.10.016 · Cited by 74
Inflow effects on functional MRI
Gao, J., & Liu, H. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.088 · Cited by 74
Martino, F. D., Esposito, F., de Moortele, P. V., Harel, N., Formisano, E., Goebel, R., Uǧurbil, K., & Yacoub, E. S. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.05.008 · Cited by 75
Wavelets in Temporal and Spatial Processing of Biomedical Images
Laine, A. F. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.511 · Cited by 74
Is cortical vasculature functionally organized?
Gardner, J. L. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.07.004 · Cited by 77
Analysis of the EEG–fMRI response to prolonged bursts of interictal epileptiform activity
Bagshaw, A. P., Hawco, C. S., Bénar, C., Kobayashi, E., Aghakhani, Y., Dubeau, F., Pike, G. B., & Gotman, J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.10.010 · Cited by 73
Functional MRI in human somatosensory cortex activated by touching textured surfaces
Lin, W., Kuppusamy, K., Haacke, E. M., & Burton, H. (1996) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880060402 · Cited by 73
Self-citationMorgan, V. L., Price, R. R., Arain, A. M., Modur, P. N., & Abou-Khalil, B. W. (2003) · NeuroImage · doi:10.1016/j.neuroimage.2003.08.031 · Cited by 71
Functional magnetic resonance imaging: imaging techniques and contrast mechanisms
Howseman, A. M., & Bowtell, R. W. (1999) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.1999.0473 · Cited by 69
Fast 3D functional magnetic resonance imaging at 1.5 T with spiral acquisition
Yang, Y., Glover, G. H., van Gelderen, P., Mattay, V. S., Santha, A. K. S., Sexton, R. H., Ramsey, N. F., MOONEN, C. T. W., Weinberger, D. R., Frank, J. A., et al. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360418 · Cited by 68
Spatial/temporal correlation of BOLD and optical intrinsic signals in humans
Pouratian, N., Sicotte, N. L., Rex, D., Martin, N. A., Becker, D., Cannestra, A. F., & Toga, A. W. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10096 · Cited by 68
T2 vertebral bone marrow changes after space flight
LeBlanc, A., Lin, C., Evans, H., Shackelford, L. C., Martin, C., & Hedrick, T. D. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199903)41:3 · Cited by 12
Lateral geniculate nucleus: anatomic and functional identification by use of MR imaging.
Fujita, N., Tanaka, H., Takanashi, M., Hirabuki, N., Abe, K., Yoshimura, H., & Nakamura, H. (2001) · PubMed Central · Cited by 67
High-resolution functional magnetic resonance imaging of the animal brain
Kim, S., & Uǧurbil, K. (2003) · Methods · doi:10.1016/s1046-2023(03)00005-7 · Cited by 66
Uǧurbil, K. (2016) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.2015.0361 · Cited by 68
Bagshaw, A. P., Kobayashi, E., Dubeau, F., Pike, G. B., & Gotman, J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.09.033 · Cited by 65
Yousry, T. A., Schmid, U. D., Schmidt, D., Hagen, T., Jassoy, A., & Reiser, M. F. (1996) · Journal of neurosurgery · doi:10.3171/jns.1996.85.4.0608 · Cited by 62
3‐dimensional functional imaging of human brain using echo‐shifted FLASH MRI
Duyn, J. H., Mattay, V. S., Sexton, R. H., Sobering, G., Barrios, F. A., Liu, G., Frank, J. A., Weinberger, D. R., & MOONEN, C. T. W. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320123 · Cited by 61
Techniques for imaging neuroscience
Turner, R., & Jones, T. (2003) · British Medical Bulletin · doi:10.1093/bmb/65.1.3 · Cited by 60
Towle, V. L., Khorasani, L., Uftring, S. J., Pelizzari, C., Erickson, R. K., Spire, J., Hoffmann, K., Chu, D., & Scherg, M. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00147-2 · Cited by 59
Heschl’s gyrus is more sensitive to tone level than non-primary auditory cortex
Hart, H. C., Palmer, A. R., & Hall, D. A. (2002) · Hearing Research · doi:10.1016/s0378-5955(02)00498-7 · Cited by 58
Segmentation of functional MRI by K-means clustering
Singh, M., Patel, P., Khosla, D., & Kim, T. (1996) · IEEE Transactions on Nuclear Science · doi:10.1109/23.507264 · Cited by 57
Krings, T., Reul, J., Spetzger, U., Klusmann, A., Roessler, F. C., Gilsbach, J. M., & Thron, A. K. (1998) · Acta Neurochirurgica · doi:10.1007/s007010050088 · Cited by 56
Imaging of Brain Tumors: Functional Magnetic Resonance Imaging and Diffusion Tensor Imaging
Gupta, A. K., Shah, A. D., Young, R. J., & Holodny, A. I. (2010) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2010.04.004 · Cited by 54
High-resolution, multiple gradient-echo functional MRI at 1.5 T
Barth, M., Reichenbach, J. R., Venkatesan, R., Moser, E., & Haacke, E. M. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)00191-x · Cited by 54
Self-citationApplications of magnetic resonance imaging to the study of human brain function
Bihan, D. L., & Karni, A. (1995) · Current Opinion in Neurobiology · doi:10.1016/0959-4388(95)80031-x · Cited by 53
Taste Memory Induces Brain Activation as Revealed by Functional MRI
Levy, L. M., Henkin, R. I., Lin, C. S., Finley, A., & Schellinger, D. (1999) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199907000-00002 · Cited by 53
Mapping of the sensorimotor cortex: functional MR and magnetic source imaging.
Roberts, T. P. L., & Rowley, H. A. (1997) · PubMed Central · Cited by 53
Kastrup, A., Li, T., Glover, G. H., Krüger, G., & Moseley, M. E. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199910000-00002 · Cited by 53
Mapping drug-induced changes in cerebral by Multiple Gradient Recalled Echo functional MRI
Chen, Q., Andersen, A. H., Zhang, Z., Ovadia, A., Gash, D. M., & Avison, M. J. (1996) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(95)02100-8 · Cited by 53
The great brain versus vein debate
Menon, R. S. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.005 · Cited by 52
Comparison of 3D BOLD Functional MRI with Spiral Acquisition at 1.5 and 4.0 T
Yang, Y., Wen, H., Mattay, V. S., Balaban, R. S., Frank, J. A., & Duyn, J. H. (1999) · NeuroImage · doi:10.1006/nimg.1998.0422 · Cited by 52
FUNCTIONAL MR IMAGING: Capabilities and Limitations
Moseley, M. E., & Glover, G. H. (1995) · Neuroimaging Clinics of North America · doi:10.1016/s1052-5149(25)00289-8 · Cited by 52
Park, S., Masamoto, K., Hendrich, K. S., Kanno, I., & Kim, S. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21573 · Cited by 51
Gonçalves, M. S., & Hall, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00394-x · Cited by 51
A multicenter measurement of magnetization transfer ratio in normal white matter
Berry, I., Barker, G. J., Barkhof, F., Campi, A., Dousset, V., Franconi, J., Gass, A., Schreiber, W., Miller, D. H., & Tofts, P. S. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199903)9:3 · Cited by 120
Self-citationRepresentation of the Visual Field in the Human Occipital Cortex
WONG, A. M. F. (1999) · Archives of Ophthalmology · doi:10.1001/archopht.117.2.208 · Cited by 50
Krings, T., Erberich, S. G., Roessler, F. C., Reul, J., & Thron, A. (1999) · PubMed Central · Cited by 50
Physicochemical Principles Influencing Magnetopharmaceuticals
SPRINGER, C. S. J. (1994) · Elsevier eBooks · doi:10.1016/b978-0-12-283980-1.50010-7 · Cited by 50
Spatial and temporal resolution of functional magnetic resonance imaging
Menon, R. S., Gati, J. S., Goodyear, B. G., Luknowsky, D. C., & Thomas, C. G. (1998) · Biochemistry and Cell Biology · doi:10.1139/bcb-76-2-3-560 · Cited by 49
Comparison of spatial and temporal pattern for fMRI obtained with BOLD and arterial spin labeling
Federspiel, A., Müller, T., Horn, H., Kiefer, C., & Strik, W. K. (2006) · Journal of Neural Transmission · doi:10.1007/s00702-006-0434-5 · Cited by 48
Functional MRI mapping of stimulus rate effects across visual processing stages
Schneider, W., Casey, B. J., & Noll, D. C. (1994) · Human Brain Mapping · doi:10.1002/hbm.460010205 · Cited by 46
Sub-millimetre resolution laminar fMRI using Arterial Spin Labelling in humans at 7 T
Kashyap, S., Ivanov, D., Havlíček, M., Huber, L., Poser, B. A., & Uludaǧ, K. (2021) · PLoS ONE · doi:10.1371/journal.pone.0250504 · Cited by 45
High-resolution segmented EPI in a motor task fMRI study
Hoogenraad, F. G. C., Pouwels, P. J. W., Hofman, M. B. M., Rombouts, S. A. R. B., Lavini, C., Leach, M. O., & Haacke, E. M. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(00)00127-2 · Cited by 45
Self-citationMagnetic Resonance Imaging of Human Brain Function
Bandettini, P. A., & Wong, E. C. (1997) · Neurosurgery Clinics of North America · doi:10.1016/s1042-3680(18)30309-7 · Cited by 44
Noninvasive quantification of cerebral blood volume in humans during functional activation
Gu, H., Lu, H., Ye, F. Q., Stein, E. A., & Yang, Y. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.09.057 · Cited by 43
TMS Orientation for NIRS-Functional Motor Mapping
Akiyama, T., Ohira, T., Kawase, T., & Kato, T. (2006) · Brain Topography · doi:10.1007/s10548-006-0007-9 · Cited by 43
Viviani, R. (2016) · Frontiers in Neuroanatomy · doi:10.3389/fnana.2016.00012 · Cited by 44
Understanding Functional Neuroimaging Methods Based on Neurovascular Coupling
Villringer, A. (1997) · Advances in experimental medicine and biology · doi:10.1007/978-1-4899-0056-2_20 · Cited by 42
Simultaneous Measurement of ΔR2 and ΔR2* in Cat Brain during Hypoxia and Hypercapnia
Prinster, A., Pierpaoli, C. M., Turner, R., & Jezzard, P. (1997) · NeuroImage · doi:10.1006/nimg.1997.0288 · Cited by 41
Barth, M., & Norris, D. G. (2007) · NMR in Biomedicine · doi:10.1002/nbm.1158 · Cited by 41
Functional Magnetic Resonance Imaging
Sexton, J. A., Deshpande, G., Li, Z., Glielmi, C. B., & Hu, X. P. (2012) · Springer eBooks · doi:10.1007/978-1-4614-5227-0_11 · Cited by 41
Buckley, P. F., Friedman, L., Wu, D. H., Lai, S., Meltzer, H. Y., Haacke, E. M., Miller, D. A., & Lewin, J. S. (1997) · Psychiatry Research Neuroimaging · doi:10.1016/s0925-4927(96)02931-9 · Cited by 40
Self-citationKinahan, P. E., & Noll, D. C. (1999) · NeuroImage · doi:10.1006/nimg.1998.0420 · Cited by 39
fMRI of the temporal lobe of the awake monkey at 7 T
Goense, J. B. M., Ku, S.-P., Merkle, H., Tolias, A. S., & Logothetis, N. K. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.09.038 · Cited by 36
Parsing the Role of the Hippocampus in Approach–Avoidance Conflict
Loh, E., Kurth-Nelson, Z. L., Berron, D., Dayan, P., Düzel, E., Dolan, R. J., & Guitart‐Masip, M. (2016) · Cerebral Cortex · doi:10.1093/cercor/bhw378 · Cited by 38
Yacoub, E. S., Uludaǧ, K., Uǧurbil, K., & Harel, N. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2008.01.046 · Cited by 38
Molecular aspects of magnetic resonance imaging and spectroscopy
Boesch, C. (1999) · Molecular Aspects of Medicine · doi:10.1016/s0098-2997(99)00007-2 · Cited by 38
Direct MRI detection of neuronal magnetic fields in the brain: Theoretical modeling
Xue, Y., Gao, J., & Xiong, J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.12.041 · Cited by 37
Siewert, B., Bly, B. M., Gottfried Schlaug, A., Darby, D., Thangaraj, V., Warach, S. J., & Edelman, R. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360212 · Cited by 37
Cognitive stimulation with the Wisconsin Card Sorting Test: functional MR imaging at 1.5 T.
Mentzel, H. J., Gaser, C., Volz, H. P., Rzanny, R., Häger, F., Sauer, H., & Kaiser, W. A. (1998) · Radiology · doi:10.1148/radiology.207.2.9577487 · Cited by 49
Baudendistel, K. T., Schad, L. R., Friedlinger, M., Wenz, F. K., Schröder, J., & Lorenz, W. J. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(95)00016-a · Cited by 35
Magnetization and diffusion effects in NMR imaging of hyperpolarized substances
Gao, J., Lemen, L. C., Xiong, J., Patyal, B. R., & Fox, P. T. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370123 · Cited by 34
Assessment of cerebral blood flow reserve using functional magnetic resonance imaging
Hedera, P., Lai, S., Lewin, J. S., Haacke, E. M., Wu, D. H., Lerner, A. J., & Friedland, R. P. (1996) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880060504 · Cited by 34
Self-citationFunctional MRI in Neuro-Oncology: State of the Art and Future Directions
Pasquini, L., Peck, K. K., Jenabi, M., & Holodny, A. I. (2023) · Radiology · doi:10.1148/radiol.222028 · Cited by 33
Aso, T., Jiang, G., Urayama, S.-I., & Fukuyama, H. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00256 · Cited by 32
Technical challenges of functional magnetic resonance imaging
Turner, R., Ordidge, R. J., Haacke, E. M., & Liang, Z. (2000) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.870231 · Cited by 33
Self-citationPredicting BOLD signal changes as a function of blood volume fraction and resolution
Cheng, Y. N., & Haacke, E. M. (2001) · NMR in Biomedicine · doi:10.1002/nbm.727 · Cited by 32
Self-citationLocalized echo‐volume imaging methods for functional MRI
Yang, Y., Mattay, V. S., Weinberger, D. R., Frank, J. A., & Duyn, J. H. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070220 · Cited by 32
Functional Magnetic Resonance Imaging
Sanders, J. A., & Orrison, W. W. (1995) · Elsevier eBooks · doi:10.1016/b978-0-8151-6509-5.50011-4 · Cited by 32
Gustard, S., Williams, E. J., Häll, L., Pickard, J. D., & Carpenter, T. A. (2003) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(03)00083-3 · Cited by 31
Explorative signal processing in functional MR imaging
Moser, E., Baumgartner, R., Barth, M., & Windischberger, C. (1999) · International Journal of Imaging Systems and Technology · doi:10.1002/(sici)1098-1098(1999)10:2 · Cited by 31
Kollias, S., Landau, K., Khan, N., Golay, X., Bernays, R. L., Yonekawa, Y., & Valavanis, A. (1998) · Journal of neurosurgery · doi:10.3171/jns.1998.89.5.0780 · Cited by 31
Chen, J. E., Glover, G. H., Fultz, N. E., Rosen, B. R., Polimeni, J. R., & Lewis, L. D. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118658 · Cited by 32
A method for determining venous contribution to BOLD contrast sensory activation
Hall, D. A., Gonçalves, M. S., Smith, S. M., Jezzard, P., Haggard, M. P., & Kornak, J. (2002) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(02)00607-0 · Cited by 30
Tian, F., Chance, B., & Liu, H. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3241984 · Cited by 30
The role of susceptibility weighted imaging in functional MRI
Haacke, E. M., & Ye, Y. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.020 · Cited by 29
Self-citationKennerley, A. J., Mayhew, J. E., Redgrave, P., & Berwick, J. (2010) · The Open Neuroimaging Journal · doi:10.2174/1874440001004010001 · Cited by 29
Clinical applications of functional MRI in neuropsychiatry
Levin, J. M., Ross, M. H., & Renshaw, P. F. (1995) · Journal of Neuropsychiatry · doi:10.1176/jnp.7.4.511 · Cited by 29
Signal Sources in Bold Contrast FMRI
Turner, R. (1997) · Advances in experimental medicine and biology · doi:10.1007/978-1-4899-0056-2_2 · Cited by 29
Hedera, P., Wu, D. H., Collins, S., Lewin, J. S., Miller, D. A., Lerner, A. J., Klein, S. K., & Friedland, R. P. (1998) · PubMed Central · Cited by 28
Self-citationPractical aspects of functional MRI (NMR Task Group #8)
Price, R. R., Allison, J. D., Massoth, R. J., Clarke, G. D., & Drost, D. J. (2002) · Medical Physics · doi:10.1118/1.1494990 · Cited by 28
Phase based venous suppression in resting-state BOLD GE-fMRI
Curtis, A. T., Hutchison, R. M., & Menon, R. S. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.05.079 · Cited by 27
Roux, F.-E. (2001) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.71.4.505 · Cited by 27
Nihashi, T., Kakigi, R., Okada, T., Sadato, N., Kashikura, K., Kajita, Y., & Yoshida, J. (2002) · NeuroImage · doi:10.1006/nimg.2002.1216 · Cited by 27
Advances in High-Field BOLD fMRI
Barth, M., & Poser, B. A. (2011) · Materials · doi:10.3390/ma4111941 · Cited by 31
Fast spin‐echo characteristics of visual stimulation‐induced signal changes in the human brain
Gao, J., Xiong, J., Li, J., Schiff, J., Roby, J. W., Lancaster, J. L., & Fox, P. T. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050615 · Cited by 27
Suppression of Vascular Artifacts in Functional Magnetic Resonance Images Using MR Angiograms
Hluštı́k, P., Noll, D. C., & Small, S. L. (1998) · NeuroImage · doi:10.1006/nimg.1998.0320 · Cited by 27
Multiresolution Data Acquisition and Detection in Functional MRI
Yoo, S., Guttmann, C. R. G., & Panych, L. P. (2001) · NeuroImage · doi:10.1006/nimg.2001.0945 · Cited by 27
CORTICAL ACTIVATION MR STUDIES IN BRAIN DISORDERS
Buchbinder, B. R., & Cosgrove, G. R. (1998) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/s1064-9689(21)00445-1 · Cited by 27
Scanning fast and slow: current limitations of 3 Tesla functional MRI and future potential
Boubela, R. N., Kalcher, K., Našel, C., & Moser, E. (2014) · Frontiers in Physics · doi:10.3389/fphy.2014.00001 · Cited by 27
Summers, P. E., Iannetti, G. D., & Porro, C. A. (2010) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2010.05.001 · Cited by 25
Metadata
- Authors
- Lai, S., Hopkins, A. L., Haacke, E. M., Li, D., Wasserman, B. A., Buckley, P., Friedman, L., Meltzer, H., Hedera, P., & Friedland, R.
- Affiliations
- Case Western Reserve University (US)
- Corresponding author
- Haacke, E. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1993-09
- Volume
- 30
- Issue
- 3
- Pages
- 387-392
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2013713875
- Cited by
- 390
- References
- 12
- Citations by year
- 2025: 2 · 2024: 6 · 2023: 3 · 2022: 2 · 2021: 5 · 2020: 2 · 2019: 2 · 2018: 2 · 2017: 7 · 2016: 4 · 2015: 8 · 2014: 8 · 2013: 3 · 2012: 13
- FWCI
- 27.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Magnetic Resonance in Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute on Aging (NIA AG08012)
- National Institute of Mental Health (NIMH 41684)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Life Sciences › Neuroscience › Cognitive Neuroscience › Functional Brain Connectivity Studies
- Keywords
- vascular architecture, motor cortex activation, finger movement, 1.5 Tesla, partial volume effect, cerebral veins, cerebral blood volume, three-dimensional MR angiography
- MeSH terms
- Brain, Cerebrovascular Circulation, Fingers, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Motor Cortex, Movement, Signal Processing, Computer-Assisted, Time Factors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review