Water diffusion in the giant axon of the squid: implications for diffusion-weighted MRI of the nervous system

Beaulieu, Christian, Allen, Peter S.·1994·Magnetic Resonance in Medicine

Abstract

To clarify the result that marked diffusional anisotropy had been found in nomyelinated nerve, and in completion of an evaluation of the role of all longitudinal axonal structures, we report NMR measurements of water diffusion in the giant axon of the squid, where diffusional anisotropy is determined by the neurofilamentary structure. The diffusion coefficients of water parallel and perpendicular to the long axis of the squid giant axon at 20 degrees C are (1.61 +/- 0.06) x 10(-5) cm2 s-1 and (1.33 +/- 0.09) x 10(-5) cm2 s-1, respectively, which yield an anisotropic diffusion ratio of 1.2 +/- 0.1. Water diffusion in the squid giant axon is therefore quite rapid and nearly isotropic, thus eliminating the possibility of a significant role for the longitudinally oriented neurofilaments in producing diffusional anisotropy within the axoplasm. In conjunction with our work on garfish nerves therefore, only membranes, either as numerous axonal membranes or as myelin (if present), remain to fulfill the role of the primary determinant of anisotropic water diffusion in nerve and in white matter.

Overview

Integrity signals

Registry

Crossref · 10.1002/mrm.1910320506

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Show all 15 references

Cited by

Sorted by citations

Metadata

Authors
Beaulieu, C., & Allen, P. S.
Affiliations
University of Alberta (CA)
Corresponding author
Allen, Peter S.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1994-11
Volume
32
Issue
5
Pages
579-583
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2005760428
Cited by
240
References
15
Citations by year
2026: 2 · 2025: 2 · 2024: 3 · 2023: 7 · 2022: 6 · 2021: 4 · 2020: 11 · 2019: 13 · 2018: 5 · 2017: 10 · 2016: 10 · 2015: 6 · 2014: 10 · 2013: 14 · 2012: 11
FWCI
3.45
Type
journal article
Language
en
Open access
closed
Locations
  • Magnetic Resonance in Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
Keywords
water diffusion, squid giant axon, diffusion-weighted imaging, neurofilaments, axoplasm, myelin, axonal membrane, white matter, diffusion coefficient
MeSH terms
Animals, Axons, Cell Membrane, Computer Simulation, Cytoplasm, Diffusion, Image Enhancement, Magnetic Resonance Imaging, Models, Neurological, Monte Carlo Method, Myelin Sheath, Nervous System, Neurofibrils, Magnetic Resonance Spectroscopy, Water, Decapodiformes

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›