Retrospective estimation and correction of physiological artifacts in fMRI by direct extraction of physiological activity from MR data
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A physiological artifact reduction method based on extracting respiratory motion and cardiac pulsation directly from functional MR data is described. In fast low angle shot (FLASH), respiratory cycles are derived utilizing the phase of the center of a navigator echo, in echo‐planar imaging (EPI) from the phase of the center κ‐space point. Cardiac cycles are determined from projections obtained from the navigator echo (FLASH) and the center κ‐space line (EPI). Because direct extraction of physiological parameters eliminates the need for external monitoring, the method can be more readily implemented. Experimental results illustrate that the technique provides effective compensation for physiology‐related signal fluctuations in functional MRI and performs as well as the retrospective technique using external physiological monitoring. Key words: fMRI; motion artifacts; physiological motion; image processing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
Stehling, M. K., Turner, R., & Mansfield, P. (1991) · Science · doi:10.1126/science.1925560 · Cited by 623
Functional magnetic resonance imaging of Brocaʼs area during internal speech
Hinke, R. M., Hu, X., Stillman, A. E., Kim, S.-G., Merkle, H., Salmi, R., & Ugurbil, K. (1993) · NeuroReport · doi:10.1097/00001756-199306000-00018 · Cited by 293
Self-citation
Cited by
Analysis of Dynamic Brain Imaging Data
Mitra, P. P., & Pesaran, B. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77236-x · Cited by 955
Triantafyllou, C., Hoge, R. D., Krueger, G., Wiggins, C. J., Potthast, A., Wiggins, G. C., & Wald, L. L. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.01.007 · Cited by 648
Methods for cleaning the BOLD fMRI signal
Caballero-Gaudes, C., & Reynolds, R. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.018 · Cited by 542
Shmueli, K., van Gelderen, P., de Zwart, J. A., Horovitz, S. G., Fukunaga, M., Jansma, J. M., & Duyn, J. H. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.07.037 · Cited by 541
Normal fMRI Brain Activation Patterns in Children Performing a Verb Generation Task
Holland, S. K., Plante, E., Weber Byars, A., Strawsburg, R. H., Schmithorst, V. J., & Ball, W. S. (2001) · NeuroImage · doi:10.1006/nimg.2001.0875 · Cited by 424
Increased sensitivity in neuroimaging analyses using robust regression
Wager, T. D., Keller, M. C., Lacey, S. C., & Jonides, J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.01.011 · Cited by 289
Noise Reduction in BOLD-Based fMRI Using Component Analysis
Thomas, C. G., Harshman, R. A., & Menon, R. S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1200 · Cited by 280
Noise contributions to the fMRI signal: An overview
Liu, T. T. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.09.008 · Cited by 275
Evaluation of the early response in fMRI in individual subjects using short stimulus duration
Hu, X., Le, T. H., & Uǧurbil, K. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370612 · Cited by 255
Self-citationEvaluating fMRI preprocessing pipelines
Strother, S. C. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1607667 · Cited by 169
“Many other approaches have been proposed for suppressing the cardiac and respiratory noise, and they fall into four groups: two based on k-space/image measurements with application of the estimated physiological correction variables in k-space [62], [63] or the reconstructed images [64], [65] and two using external mo…”
BackgroundMethods for assessing accuracy and reliability in functional MRI
Le, T. H., & Hu, X. P. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<160::aid-nbm458>3.0.co;2-a · Cited by 49
Self-citationSvedin, B. T., Payne, A., & Parker, D. L. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25860 · Cited by 30
“Some methods use free induction decay (FID) navigators (16), whereas others apply a gradient during navigator readout (11,15,17) or extract the navigator information from the k-space data itself (ie, they are self-navigated) (10,18,19).”
Method(1998) · doi:10.1002/(sici)1097-0193(1998)6:3<160::aid-hbm5>3.0.co;2-1
Metadata
- Authors
- Le, T. H., & Hu, X.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1996-03
- Volume
- 35
- Issue
- 3
- Pages
- 290-298
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2031448128
- Cited by
- 146
- References
- 6
- FWCI
- 13.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.