The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Evaluation of the early response in fMRI in individual subjects using short stimulus duration
Abstract
Optical imaging studies have provided evidence of an initial increase in deoxyhemoglobin following the onset of neuronal stimulation/activation and demonstrated that this initial increase could be spatially more specific to the site of neuronal activity. These studies also raised the possibility of improving the specificity of fMRI by selective mapping of this early response. Previous MR studies reported the observation of this early response but were limited in scope and not in full agreement. This paper presents a more extensive study that (a) demonstrates the initial signal decrease in individual subjects and (b) examines its dependence on stimulus duration and subject. Binocular visual stimulation experiments were performed on 14 subjects using echo‐planar imaging (EPI) with high temporal resolution. An initial signal decrease was consistently observed in regions that were more localized than those displaying the delayed positive response. In agreement with previous fMRI and optical imaging findings, the maximum signal decrease was 1–2% and occurred at approximately 2 s after the onset of the stimulus, depending on the subject. For stimulus longer than 3.0 s, the temporal dynamics and the amount of signal change of the early response was essentially independent of the stimulus duration, while the delayed response and the post‐stimulus undershoot increased both in terms of magnitude and rise time as the duration of the stimulus increased; this observation is concordant with the recent optical imaging study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
Ogawa, S., Lee, T., Nayak, A. S., & Glynn, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140108 · Cited by 2,266
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Multi-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813
Processing strategies for time‐course data sets in functional mri of the human brain
Bandettini, P. A., Jesmanowicz, A., Wong, E. C., & Hyde, J. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300204 · Cited by 1,763
Brain magnetic resonance imaging with contrast-dependent oxygenation
Ogawa, S. (1990) · Medical Entomology and Zoology · Cited by 1,367
FLASH imaging: Rapid NMR imaging using low flip-angle pulses
Haase, A., Frahm, J., Matthaei, D., Hänicke, W., & Merboldt, K.-D. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.09.021 · Cited by 1,153
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Cited by
Neurophysiological investigation of the basis of the fMRI signal
Logothetis, N. K., Pauls, J., Augath, M., Trinath, T., & Oeltermann, A. (2001) · Nature · doi:10.1038/35084005 · Cited by 6,551
Dynamics of blood flow and oxygenation changes during brain activation: the Balloon model
Buxton, R. B., Wong, E. C., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390602 · Cited by 1,665
What does fMRI tell us about neuronal activity?
Heeger, D. J., & Ress, D. (2002) · Nature Reviews Neuroscience · doi:10.1038/nrn730 · Cited by 1,085
Beyond the Visible???Imaging the Human Brain With Light
Obrig, H., & Villringer, A. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200301000-00001 · Cited by 892
?sparse? temporal sampling in auditory fMRI
Hall, D. A., Haggard, M. P., Akeroyd, M. A., Palmer, A. R., Summerfield, A. Q., Elliott, M. R., Gurney, E. M., & Bowtell, R. W. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)7:3<213::aid-hbm5>3.0.co;2-n · Cited by 869
Metadata
- Authors
- Hu, X., Le, T. H., & Uǧurbil, K.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1997-06
- Volume
- 37
- Issue
- 6
- Pages
- 877-884
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2083834416
- Cited by
- 255
- References
- 33
- FWCI
- 26.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of the early response in fMRI in individual subjects using short stimulus duration. https://app.cochat.ai/papers/10.1002/mrm.1910370612
- The paper
- Hu, X., Le, T. H., & Uǧurbil, K. (1997). Evaluation of the early response in fMRI in individual subjects using short stimulus duration. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910370612
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.