Abstract
Functional magnetic resonance imaging (fMRI) of the brain is often degraded by bulk head motion. Algorithms that address this by retrospective re‐registration of images in an fMRI time series are all fundamentally limited by any motion that occurs through‐plane. Here, a technique is described that can account for such motion by prospective. correction in real time. A navigator echo is used before every image acquisition to detect superior/inferior displacements of the head. The displacement information is then used to adjust the plane of excitation of the ensuing single‐shot echo‐planar fMRI axial image. These correction updates can be completed in 100 ms with motion sensitivity at least as small as 0.5 mm. The efficacy of this method is documented in phantom and human studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
McCarthy, G., Blamire, A. M., Puce, A., Nobre, A. C., Bloch, G., Hyder, F., Goldman-Rakic, P., & Shulman, R. G. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.18.8690 · Cited by 459
Functional magnetic resonance imaging of Brocaʼs area during internal speech
Hinke, R. M., Hu, X., Stillman, A. E., Kim, S.-G., Merkle, H., Salmi, R., & Ugurbil, K. (1993) · NeuroReport · doi:10.1097/00001756-199306000-00018 · Cited by 293
Cited by
Prospective acquisition correction for head motion with image-based tracking for real-time fMRI
Thesen, S., Heid, O., Mueller, E., & Schad, L. R. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<457::aid-mrm17>3.0.co;2-r · Cited by 572
Methods for cleaning the BOLD fMRI signal
Caballero-Gaudes, C., & Reynolds, R. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.018 · Cited by 542
“…et al., 2014; Speck et al., 2006; Todd et al., 2015) or the use of dedicated sequences with navigators echoes or active markers (Hu and Kim, 1994; Lee et al., 1996; Muraskin et al., 2013; Pfeuffer et al., 2002; White et al., 2010) can be useful for prospective motion correction (Zaitsev et al.,…”
Prospective motion correction in brain imaging: A review
Maclaren, J., Herbst, M., Speck, O., & Zaitsev, M. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24314 · Cited by 401
Callicott, J. (1998) · Neuropsychopharmacology · doi:10.1016/s0893-133x(97)00096-1 · Cited by 322
Motion correction in MRI of the brain
Godenschweger, F., Kägebein, U., Stucht, D., Yarach, U., Sciarra, A., Yakupov, R., Lüsebrink, F., Schulze, P., & Speck, O. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/5/r32 · Cited by 221
Spherical navigator echoes for full 3D rigid body motion measurement in MRI
Welch, E. B., Manduca, A., Grimm, R. C., Ward, H. A., & Jack Jr., C. R. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10012 · Cited by 212
“kz n k cos n [17] Table 2 Average (N 24) “Along Thread” SNAV Motion Detection Versus Intended Motion and ONAV Results”
BackgroundSelf-citationMethods for assessing accuracy and reliability in functional MRI
Le, T. H., & Hu, X. P. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<160::aid-nbm458>3.0.co;2-a · Cited by 49
CUDA accelerated method for motion correction in MR PROPELLER imaging
Feng, C., Yang, J., Zhao, D., & Liu, J. (2013) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2013.04.013 · Cited by 8
“In prospective correction methods, motion and movement are compensated during data acquisition by changing the scanner coordinate system according to the patient in real-time [4], introducing additional navigator echoes [5,6], attaching active markers to the patient [3,7], or utilizing external tracking systems [8].”
Method
Metadata
- Authors
- Lee, C. C., Jack, C. R., Grimm, R. C., Rossman, P. J., Felmlee, J. P., Ehman, R. L., & Riederer, S. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1996-09
- Volume
- 36
- Issue
- 3
- Pages
- 436-444
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2129936914
- Cited by
- 100
- References
- 7
- FWCI
- 5.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).