CoChat

Real‐time adaptive motion correction in functional MRI

Lee, Christine C., Jack, Clifford R., Grimm, Roger C., Rossman, Phillip J., Felmlee, Joel P., Ehman, Richard L., Riederer, Stephen J. · 1996 · Magnetic Resonance in Medicine
Cited by 100

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Functional magnetic resonance imaging (fMRI) of the brain is often degraded by bulk head motion. Algorithms that address this by retrospective re‐registration of images in an fMRI time series are all fundamentally limited by any motion that occurs through‐plane. Here, a technique is described that can account for such motion by prospective. correction in real time. A navigator echo is used before every image acquisition to detect superior/inferior displacements of the head. The displacement information is then used to adjust the plane of excitation of the ensuing single‐shot echo‐planar fMRI axial image. These correction updates can be completed in 100 ms with motion sensitivity at least as small as 0.5 mm. The efficacy of this method is documented in phantom and human studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910360316

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 100

Metadata

Authors
Lee, C. C., Jack, C. R., Grimm, R. C., Rossman, P. J., Felmlee, J. P., Ehman, R. L., & Riederer, S. J.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1996-09
Volume
36
Issue
3
Pages
436-444
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2129936914
Cited by
100
References
7
FWCI
5.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.