Evidence for the exchange of arterial spin‐labeled water with tissue water in rat brain from diffusion‐sensitized measurements of perfusion
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The extraction fraction of vascular water in rat brain is investigated by means of diffusion measurements of arterial spin labeled water at varying cerebral blood flow (CBF) values. The apparent diffusion coefficient (ADC) of the difference of the proton magnetization signal in the brain acquired with and without continuous arterial spin labeling is modeled to provide a measure of the amount of arterial water in tissue and vasculature and thus of the extraction fraction. The tissue and vascular portion of the arterial spin labeled water are differentiated based on their diffusion characteristics in a manner analogous to the intravoxel incoherent motion (IVIM) method. The amount of labeled arterial water that exchanges with tissue water is determined by estimating the fraction of the total signal that is associated with the slow‐decaying component of a biexponential fit to the normalized difference signal between the magnetization of brain tissue acquired with and without arterial spin labeling. The results indicate that, at normal CBF (1.15 ± 0.21 ml g‐1 min‐1), about 90% of the arterial spin labeled water diffuses with an ADC of (1.21 ± 0.37) 10‐3 mm 2 s‐1), which is equal to tissue. At high CBF, an increasing fraction of the labeling water has a fast‐pseudo‐diffusion coefficient due to a decrease in water extraction fractions. The results also show that the contribution of vascular water to the measurement of perfusion by techniques that use endogenous water as a tracer can be efficiently eliminated by the use of diffusion sensitizing gradients with small effective b values (b ≈ 20 s/mm 2), enabling these techniques to monitor true changes in tissue perfusion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
The capillary network: A link between IVIM and classical perfusion
Bihan, D. L., & Turner, R. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910270116 · Cited by 423
Diffusion weighted fMRI at 1.5 T
Song, A. W., Wong, E. C., Tan, S. G., & Hyde, J. S. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350204 · Cited by 208
Cited by
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
Calamante, F., Thomas, D. L., Pell, G. S., Wiersma, J., & Turner, R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199907000-00001 · Cited by 638
What can we see with IVIM MRI?
Le Bihan, D. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.062 · Cited by 498
Gleaning multicomponent T1 and T2 information from steady‐state imaging data
Deoni, S. C. L., Rutt, B. K., Arun, T., Pierpaoli, C., & Jones, D. K. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21704 · Cited by 472
Methodology of brain perfusion imaging
Barbier, E. L., Lamalle, L., & Décorps, M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1073 · Cited by 404
Intravoxel Incoherent Motion Perfusion MR Imaging: A Wake-Up Call
Le Bihan, D. (2008) · Radiology · doi:10.1148/radiol.2493081301 · Cited by 298
Metadata
- Authors
- Silva, A. C., Williams, D. S., & Koretsky, A. P.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1997-08
- Volume
- 38
- Issue
- 2
- Pages
- 232-237
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2119025182
- Cited by
- 103
- References
- 4
- FWCI
- 3.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.