Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Abstract
SiMultaneous Acquisition of Spatial Harmonics (SMASH) is a new fast‐imaging technique that increases MR image acquisition speed by an integer factor over existing fast‐imaging methods, without significant sacrifices in spatial resolution or signal‐to‐noise ratio. Image acquisition time is reduced by exploiting spatial information inherent in the geometry of a surface coil array to substitute for some of the phase encoding usually produced by magnetic field gradients. This allows for partially parallel image acquisitions using many of the existing fast‐imaging sequences. Unlike the data combination algorithms of prior proposals for parallel imaging, SMASH reconstruction involves a small set of MR signal combinations prior to Fourier transformation, which can be advantageous for artifact handling and practical implementation. A twofold savings in image acquisition time is demonstrated here using commercial phased array coils on two different MR‐imaging systems. Larger time savings factors can be expected for appropriate coil designs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The rician distribution of noisy mri data
Gudbjartsson, H., & Patz, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340618 · Cited by 2,494
Roemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322
RARE imaging: A fast imaging method for clinical MR
Hennig, J., Nauerth, A., & Friedburg, H. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030602 · Cited by 2,081
Multi-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813
FLASH imaging: Rapid NMR imaging using low flip-angle pulses
Haase, A., Frahm, J., Matthaei, D., Hänicke, W., & Merboldt, K.-D. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.09.021 · Cited by 1,153
The signal-to-noise ratio of the nuclear magnetic resonance experiment
Hoult, D. I., & Richards, R. E. (1976) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(76)90233-x · Cited by 1,132
FLASH imaging. Rapid NMR imaging using low flip-angle pulses
Haase, A., Frahm, J., Matthaei, D., Hanicke, W., & Merboldt, K.-D. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90433-6 · Cited by 826
Homodyne detection in magnetic resonance imaging
Noll, D. C., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.79473 · Cited by 514
High-Speed Spiral-Scan Echo Planar NMR Imaging-I
Ahn, C. B., Kim, J. H., & Cho, Z. H. (1986) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1986.4307732 · Cited by 487
Fast MRI data acquisition using multiple detectors
Hutchinson, M., & Raff, U. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910060110 · Cited by 195
Volume imaging with MR phased arrays
Hayes, C. E., Hattes, N., & Roemer, P. B. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180206 · Cited by 178
Fast imaging using subencoding data sets from multiple detectors
Ra, J. B., & Rim, C. Y. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300123 · Cited by 163
Noise correlations in data simultaneously acquired from multiple surface coil arrays
Hayes, C. E., & Roemer, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160202 · Cited by 136
Wald, L. L., Carvajal, L. E., Moyher, S. E., Nelson, S. J., Grant, P. E., Barkovich, A. J., & Vigneron, D. B. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340321 · Cited by 132
Imaging time reduction through multiple receiver coil data acquisition and image reconstruction
Carlson, J. W., & Minemura, T. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290516 · Cited by 130
A decoupled coil detector array for fast image acquisition in magnetic resonance imaging
Kwiat, D., Einav, S., & Navon, G. (1991) · Medical Physics · doi:10.1118/1.596723 · Cited by 110
Intensity correction of phased‐array surface coil images
Murakami, J. W., Hayes, C. E., & Weinberger, E. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350419 · Cited by 95
Hennig, J., & Hodapp, M. T. (1993) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/bf02660372 · Cited by 93
Cited by
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Lustig, M., Donoho, D. L., Santos, J. M., & Pauly, J. M. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914728 · Cited by 2,246
Learning a variational network for reconstruction of accelerated MRI data
Hammernik, K., Klatzer, T., Kobler, E., Recht, M. P., Sodickson, D. K., Pock, T., & Knoll, F. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26977 · Cited by 1,713
Self-citation
Metadata
- Authors
- Sodickson, D. K., & Manning, W. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1997-10
- Volume
- 38
- Issue
- 4
- Pages
- 591-603
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W4233764193
- Cited by
- 2,142
- References
- 18
- FWCI
- 18.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.