The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Abstract
SiMultaneous Acquisition of Spatial Harmonics (SMASH) is a new fast‐imaging technique that increases MR image acquisition speed by an integer factor over existing fast‐imaging methods, without significant sacrifices in spatial resolution or signal‐to‐noise ratio. Image acquisition time is reduced by exploiting spatial information inherent in the geometry of a surface coil array to substitute for some of the phase encoding usually produced by magnetic field gradients. This allows for partially parallel image acquisitions using many of the existing fast‐imaging sequences. Unlike the data combination algorithms of prior proposals for parallel imaging, SMASH reconstruction involves a small set of MR signal combinations prior to Fourier transformation, which can be advantageous for artifact handling and practical implementation. A twofold savings in image acquisition time is demonstrated here using commercial phased array coils on two different MR‐imaging systems. Larger time savings factors can be expected for appropriate coil designs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The rician distribution of noisy mri data
Gudbjartsson, H., & Patz, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340618 · Cited by 2,494
Roemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322
RARE imaging: A fast imaging method for clinical MR
Hennig, J., Nauerth, A., & Friedburg, H. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030602 · Cited by 2,081
Multi-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813
FLASH imaging: Rapid NMR imaging using low flip-angle pulses
Haase, A., Frahm, J., Matthaei, D., Hänicke, W., & Merboldt, K.-D. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.09.021 · Cited by 1,153
The signal-to-noise ratio of the nuclear magnetic resonance experiment
Hoult, D. I., & Richards, R. E. (1976) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(76)90233-x · Cited by 1,132
FLASH imaging. Rapid NMR imaging using low flip-angle pulses
Haase, A., Frahm, J., Matthaei, D., Hanicke, W., & Merboldt, K.-D. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90433-6 · Cited by 826
Homodyne detection in magnetic resonance imaging
Noll, D. C., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.79473 · Cited by 514
High-Speed Spiral-Scan Echo Planar NMR Imaging-I
Ahn, C. B., Kim, J. H., & Cho, Z. H. (1986) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1986.4307732 · Cited by 487
Fast MRI data acquisition using multiple detectors
Hutchinson, M., & Raff, U. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910060110 · Cited by 195
Cited by
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Lustig, M., Donoho, D. L., Santos, J. M., & Pauly, J. M. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914728 · Cited by 2,246
Learning a variational network for reconstruction of accelerated MRI data
Hammernik, K., Klatzer, T., Kobler, E., Recht, M. P., Sodickson, D. K., Pock, T., & Knoll, F. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26977 · Cited by 1,713
Self-citationSetsompop, K., Gagoski, B. A., Polimeni, J. R., Witzel, T., Wedeen, V. J., & Wald, L. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23097 · Cited by 1,285
Advances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
Dietrich, O., Raya, J. G., Reeder, S. B., Reiser, M. F., & Schoenberg, S. O. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20969 · Cited by 992
Uğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Twenty‐five pitfalls in the analysis of diffusion MRI data
Jones, D. K., & Cercignani, M. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1543 · Cited by 827
SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐space
Lustig, M., & Pauly, J. M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22428 · Cited by 822
k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
Tsao, J., Boesiger, P., & Pruessmann, K. P. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10611 · Cited by 794
Motion artifacts in MRI: A complex problem with many partial solutions
Zaitsev, M., Maclaren, J., & Herbst, M. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24850 · Cited by 774
Katscher, U., Börnert, P., Leussler, C., & van den Brink, J. S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10353 · Cited by 719
Feng, L., Grimm, R., Block, K. T., Chandarana, H., Kim, S., Xu, J., Axel, L., Sodickson, D. K., & Otazo, R. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24980 · Cited by 718
Self-citationReeder, S. B., Pineda, A. R., Wen, Z., Shimakawa, A., Yu, H., Brittain, J. H., Gold, G. E., Beaulieu, C. H., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20624 · Cited by 706
k‐t FOCUSS: A general compressed sensing framework for high resolution dynamic MRI
Jung, H., Sung, K., Nayak, K. S., Kim, E. Y., & Ye, J. C. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21757 · Cited by 669
High-field MRI of brain cortical substructure based on signal phase
Duyn, J. H., van Gelderen, P., Li, T.-Q., de Zwart, J. A., Koretsky, A. P., & Fukunaga, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610821104 · Cited by 641
Breuer, F. A., Blaimer, M., Heidemann, R. M., Mueller, M. F., Griswold, M. A., & Jakob, P. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20401 · Cited by 633
Dixon techniques for water and fat imaging
Ma, J. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21492 · Cited by 610
Compressive Sensing via Nonlocal Low-Rank Regularization
Dong, W., Shi, G., Li, X., Ma, Y., & Huang, F. (2014) · IEEE Transactions on Image Processing · doi:10.1109/tip.2014.2329449 · Cited by 598
Otazo, R., Kim, D., Axel, L., & Sodickson, D. K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22463 · Cited by 571
Self-citationCompressed sensing in dynamic MRI
Gamper, U., Boesiger, P., & Kozerke, S. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21477 · Cited by 569
The Statistical Analysis of fMRI Data
Lindquist, M. A. (2008) · Statistical Science · doi:10.1214/09-sts282 · Cited by 563
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Simultaneous multislice (SMS) imaging techniques
Barth, M., Breuer, F., Koopmans, P. J., Norris, D. G., & Poser, B. A. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25897 · Cited by 534
Deep learning for tomographic image reconstruction
Wang, G., Ye, J. C., & De Man, B. (2020) · Nature Machine Intelligence · doi:10.1038/s42256-020-00273-z · Cited by 531
Evaluation of slice accelerations using multiband echo planar imaging at 3T
Xu, J., Moeller, S., Auerbach, E. J., Strupp, J., Smith, S. M., Feinberg, D. A., Yacoub, E., & Uğurbil, K. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.07.055 · Cited by 514
Accelerating SENSE using compressed sensing
Liang, D., Liu, B., Wang, J., & Ying, L. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22161 · Cited by 474
B1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil
Van de Moortele, P., Akgun, C., Adriany, G., Moeller, S., Ritter, J., Collins, C. M., Smith, M. B., Vaughan, J. T., & Uğurbil, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20708 · Cited by 468
SMASH, SENSE, PILS, GRAPPA: How to Choose the Optimal Method
Blaimer, M., Breuer, F., Mueller, M., Heidemann, R. M., Griswold, M. A., & Jakob, P. M. (2004) · Topics in Magnetic Resonance Imaging · doi:10.1097/01.rmr.0000136558.09801.dd · Cited by 449
Poser, B. A., Versluis, M. J., Hoogduin, J. M., & Norris, D. G. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20900 · Cited by 439
Robson, P. M., Grant, A. K., Madhuranthakam, A. J., Lattanzi, R., Sodickson, D. K., & McKenzie, C. A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21728 · Cited by 438
Self-citationReal‐time MRI at a resolution of 20 ms
Uecker, M., Zhang, S., Voit, D., Karaus, A., Merboldt, K., & Frahm, J. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1585 · Cited by 434
Deep learning for undersampled MRI reconstruction
Hyun, C. M., Kim, H. P., Lee, S. M., Lee, S., & Seo, J. K. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aac71a · Cited by 428
Transmit and receive transmission line arrays for 7 Tesla parallel imaging
Adriany, G., Van de Moortele, P., Wiesinger, F., Moeller, S., Strupp, J. P., Andersen, P., Snyder, C., Zhang, X., Chen, W., Pruessmann, K. P., et al. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20321 · Cited by 421
Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA)
Breuer, F. A., Blaimer, M., Mueller, M. F., Seiberlich, N., Heidemann, R. M., Griswold, M. A., & Jakob, P. M. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20787 · Cited by 413
Knoll, F., Zbontar, J., Sriram, A., Muckley, M. J., Bruno, M., Defazio, A., Parente, M., Geras, K. J., Katsnelson, J., Chandarana, H., et al. (2020) · Radiology: Artificial Intelligence · doi:10.1148/ryai.2020190007 · Cited by 409
Self-citationMiyazaki, M., & Lee, V. S. (2008) · Radiology · doi:10.1148/radiol.2481071497 · Cited by 407
Knoll, F., Hammernik, K., Zhang, C., Moeller, S., Pock, T., Sodickson, D. K., & Akcakaya, M. (2020) · IEEE Signal Processing Magazine · doi:10.1109/msp.2019.2950640 · Cited by 403
Self-citationCompressed sensing MRI: a review of the clinical literature
Jaspan, O. N., Fleysher, R., & Lipton, M. L. (2015) · The British Journal of Radiology · doi:10.1259/bjr.20150487 · Cited by 393
Akçakaya, M., Moeller, S., Weingärtner, S., & Uğurbil, K. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27420 · Cited by 391
Calibrationless parallel imaging reconstruction based on structured low-rank matrix completion
Shin, P. J., Larson, P. E. Z., Ohliger, M. A., Elad, M., Pauly, J. M., Vigneron, D. B., & Lustig, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24997 · Cited by 391
Diffusion Tensor MR Imaging and Fiber Tractography: Technical Considerations
Mukherjee, P., Chung, S. W., Berman, J. I., Hess, C. P., & Henry, R. G. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1052 · Cited by 390
Optimized three‐dimensional fast‐spin‐echo MRI
Mugler, J. P. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24542 · Cited by 376
Fat and water magnetic resonance imaging
Bley, T. A., Wieben, O., François, C. J., Brittain, J. H., & Reeder, S. B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21895 · Cited by 372
Fat-Suppression Techniques for 3-T MR Imaging of the Musculoskeletal System
Del Grande, F., Santini, F., Herzka, D. A., Aro, M. R., Dean, C. W., Gold, G. E., & Carrino, J. A. (2014) · RadioGraphics · doi:10.1148/rg.341135130 · Cited by 370
SPATIOTEMPORAL IMAGINGWITH PARTIALLY SEPARABLE FUNCTIONS
Liang, Z.-P. (2007) · 2007 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro · doi:10.1109/isbi.2007.357020 · Cited by 369
Q‐ball reconstruction of multimodal fiber orientations using the spherical harmonic basis
Hess, C. P., Mukherjee, P., Han, E. T., Xu, D., & Vigneron, D. B. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20931 · Cited by 366
Improving diffusion MRI using simultaneous multi-slice echo planar imaging
Setsompop, K., Cohen-Adad, J., Gagoski, B. A., Raij, T., Yendiki, A., Keil, B., Wedeen, V. J., & Wald, L. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.033 · Cited by 355
Zaitsev, M., Hennig, J., & Speck, O. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20261 · Cited by 349
Gadgetron: An open source framework for medical image reconstruction
Hansen, M. S., & Sørensen, T. S. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24389 · Cited by 339
Model-Based Image Reconstruction for MRI
Fessler, J. (2010) · IEEE Signal Processing Magazine · doi:10.1109/msp.2010.936726 · Cited by 335
Partially parallel imaging with localized sensitivities (PILS)
Griswold, M. A., Jakob, P. M., Nittka, M., Goldfarb, J. W., & Haase, A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200010)44:4<602::aid-mrm14>3.0.co;2-5 · Cited by 329
Parallel magnetic resonance imaging
Larkman, D. J., & Nunes, R. G. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/7/r01 · Cited by 327
Results of the 2020 fastMRI challenge for machine learning MR image reconstruction
Muckley, M. J., Riemenschneider, B., Radmanesh, A., Kim, S., Jeong, G., Ko, J., Jun, Y., Shin, H., Hwang, D., Mostapha, M., et al. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3075856 · Cited by 313
Murphy, M., Alley, M., Demmel, J., Keutzer, K., Vasanawala, S., & Lustig, M. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2188039 · Cited by 313
Bammer, R., Keeling, S. L., Augustin, M., Pruessmann, K. P., Wolf, R., Stollberger, R., Hartung, H., & Fazekas, F. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1226 · Cited by 311
Compressed sensing for body MRI
Feng, L., Benkert, T., Block, K. T., Sodickson, D. K., Otazo, R., & Chandarana, H. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25547 · Cited by 306
Self-citationReeder, S. B., Wintersperger, B. J., Dietrich, O., Lanz, T., Greiser, A., Reiser, M. F., Glazer, G. M., & Schoenberg, S. O. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20636 · Cited by 302
End-to-End Variational Networks for Accelerated MRI Reconstruction
Sriram, A., Zbontar, J., Murrell, T., Defazio, A., Zitnick, C. L., Yakubova, N., Knoll, F., & Johnson, P. (2020) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-59713-9_7 · Cited by 301
4D Flow cardiovascular magnetic resonance consensus statement: 2023 update
Bissell, M. M., Raimondi, F., Ait Ali, L., Allen, B. D., Barker, A. J., Bolger, A., Burris, N., Carhäll, C.-J., Collins, J. D., Ebbers, T., et al. (2023) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-023-00942-z · Cited by 296
k‐t PCA: Temporally constrained k‐t BLAST reconstruction using principal component analysis
Pedersen, H., Kozerke, S., Ringgaard, S., Nehrke, K., & Kim, W. Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22052 · Cited by 294
Artificial Intelligence for MR Image Reconstruction: An Overview for Clinicians
Lin, D. J., Johnson, P. M., Knoll, F., & Lui, Y. W. (2021) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.27078 · Cited by 291
Electrodynamics and ultimate SNR in parallel MR imaging
Wiesinger, F., Boesiger, P., & Pruessmann, K. P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20183 · Cited by 282
AUTO-SMASH: A self-calibrating technique for SMASH imaging
Jakob, P. M., Grisowld, M. A., Edelman, R. R., & Sodickson, D. K. (1998) · Magma: Magnetic Resonance Materials in Physics, Biology, and Medicine · doi:10.1007/bf02592256 · Cited by 278
Self-citationCoil compression for accelerated imaging with Cartesian sampling
Zhang, T., Pauly, J. M., Vasanawala, S. S., & Lustig, M. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24267 · Cited by 273
Sodium and T1ρ MRI for molecular and diagnostic imaging of articular cartilage
Borthakur, A., Mellon, E., Niyogi, S., Witschey, W., Kneeland, J. B., & Reddy, R. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1102 · Cited by 266
Parallel imaging reconstruction using automatic regularization
Lin, F., Kwong, K. K., Belliveau, J. W., & Wald, L. L. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10718 · Cited by 266
Knoll, F., Murrell, T., Sriram, A., Yakubova, N., Zbontar, J., Rabbat, M., Defazio, A., Muckley, M. J., Sodickson, D. K., Zitnick, C. L., et al. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28338 · Cited by 263
Self-citationArray compression for MRI with large coil arrays
Buehrer, M., Pruessmann, K. P., Boesiger, P., & Kozerke, S. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21237 · Cited by 257
Interslice leakage artifact reduction technique for simultaneous multislice acquisitions
Cauley, S. F., Polimeni, J. R., Bhat, H., Wald, L. L., & Setsompop, K. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24898 · Cited by 255
Advancements in MR Imaging of the Prostate: From Diagnosis to Interventions
Bonekamp, D., Jacobs, M. A., El-Khouli, R., Stoianovici, D., & Macura, K. J. (2011) · RadioGraphics · doi:10.1148/rg.313105139 · Cited by 254
Uecker, M., Hohage, T., Block, K. T., & Frahm, J. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21691 · Cited by 253
Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP)
Kyriakos, W. E., Panych, L. P., Kacher, D. F., Westin, C.-F., Bao, S. M., Mulkern, R. V., & Jolesz, F. A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200008)44:2<301::aid-mrm18>3.0.co;2-d · Cited by 253
Linear inverse problems in imaging
Ribes, A., & Schmitt, F. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.923099 · Cited by 154
Oxytocin Modulates Neural Reactivity to Children's Faces as a Function of Social Salience
Wittfoth-Schardt, D., Gründing, J., Wittfoth, M., Lanfermann, H., Heinrichs, M., Domes, G., Buchheim, A., Gündel, H., & Waller, C. (2012) · Neuropsychopharmacology · doi:10.1038/npp.2012.47 · Cited by 139
Scalable multichannel MRI data acquisition system
Bodurka, J., Ledden, P. J., van Gelderen, P., Chu, R., de Zwart, J. A., Morris, D., & Duyn, J. H. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10693 · Cited by 71
Metadata
- Authors
- Sodickson, D. K., & Manning, W. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1997-10
- Volume
- 38
- Issue
- 4
- Pages
- 591-603
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W4233764193
- Cited by
- 2,142
- References
- 18
- FWCI
- 18.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.