The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Imaging anisotropic and viscous properties of breast tissue by magnetic resonance‐elastography
Open accessAbstract
MR‐elastography is a new technique for assessing the viscoelastic properties of tissue. One current focus of elastography is the provision of new physical parameters for improving the specificity in breast cancer diagnosis. This analysis describes a technique to extend the reconstruction to anisotropic elastic properties in terms of a so‐called transversely isotropic model. Viscosity is treated as being isotropic. The particular model chosen for the anisotropy is appealing because it is capable of describing elastic shear anisotropy of parallel fibers. The dependence of the reconstruction on the particular choice of Poisson's ratio is eliminated by extracting the compressional displacement contribution using the Helmholtz–Hodge decomposition. Results are presented for simulations, a polyvinyl alcohol breast phantom, excised beef muscle, and measurements in two patients with breast lesions (invasive ductal carcinoma and fibroadenoma). The results show enhanced anisotropic and viscous properties inside the lesions and an indication for preferred fiber orientation. Magn Reson Med 53:372–387, 2005. © 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Acoustic Fields and Waves in Solids
Auld, B. A. (1973) · Medical Entomology and Zoology · Cited by 5,827
Theory of Elasticity (3rd ed.)
Timoshenko, S. P., Goodier, J. N., & Abramson, H. N. (1970) · Journal of Applied Mechanics · doi:10.1115/1.3408648 · Cited by 4,021
Kinsler, L. E., Frey, A. R., & Bennett, G. S. (1951) · American Journal of Physics · doi:10.1119/1.1932798 · Cited by 3,375
Biomechanics: Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1981) · Journal of Biomechanical Engineering · doi:10.1115/1.3138285 · Cited by 2,769
Duck, F. A. (1990) · Cited by 2,461
Multi-Grid Methods and Applications
Hackbusch, W. (1985) · Springer Series in Computational Mathematics · doi:10.1007/978-3-662-02427-0 · Cited by 2,223
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
Elastic Moduli of Breast and Prostate Tissues under Compression
Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000403 · Cited by 1,703
Elastography of breast lesions: initial clinical results.
Garra, B. S., Cespedes, E. I., Ophir, J., Spratt, S. R., Zuurbier, R. A., Magnant, C. M., & Pennanen, M. F. (1997) · Radiology · doi:10.1148/radiology.202.1.8988195 · Cited by 940
Physical properties of tissue: F. A. Duck Harcourt Brace Jovanovich Ltd, London; 1990, 346 pp.
Bowker, P. (1991) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(91)90034-5 · Cited by 608
[Mechanical properties of living tissues].
Sato, M. (1986) · PubMed · Cited by 516
High-resolution tensor MR elastography for breast tumour detection
Sinkus, R., Lorenzen, J., Schrader, D., Lorenzen, M., Dargatz, M., & Holz, D. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/317 · Cited by 481
Self-citationPadole, N. N., & Padole, N. N. (2024) · Handbook of Vibroacoustics, Noise and Harshness · doi:10.1007/978-981-99-4638-9_40-1 · Cited by 426
Tissue characterization using magnetic resonance elastography: preliminary results*
Kruse, S. A., Smith, J. A., Lawrence, A. J., Dresner, M. A., Manduca, A., Greenleaf, J. F., Ehman, R. L., Kruse, S. A., Smith, J. A., Lawrence, A. J., et al. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/313 · Cited by 340
Gelation of aqueous gelatin solutions. II. Rheology of the sol-gel transition
Djabourov, M., Leblond, J., & Papon, P. (1988) · Journal de Physique · doi:10.1051/jphys:01988004902033300 · Cited by 273
Gennisson, J.-L., Catheline, S., Chaffaı̈, S., & Fink, M. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1579008 · Cited by 272
Self-citationThree‐dimensional subzone‐based reconstruction algorithm for MR elastography
Van Houten, E. E. W., Miga, M. I., Weaver, J. B., Kennedy, F. E., & Paulsen, K. D. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1111 · Cited by 179
Mammography and Beyond: Developing Technologies for the Early Detection of Breast Cancer
Nass, S. J., Henderson, I. C., & Lashof, J. C. (2013) · Cited by 167
Mammography and Beyond: Developing Technologies for the Early Detection of Breast Cancer
Cullinan, J. A. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.1.1790042 · Cited by 123
Magnetic resonance imaging of shear wave propagation in excised tissue
Bishop, J. E., Poole, G., Leitch, M., & Plewes, D. B. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080613 · Cited by 118
Houten, E. E. W. V., Weaver, J. B., Miga, M. I., Kennedy, F. E., & Paulsen, K. D. (2000) · Medical Physics · doi:10.1118/1.598861 · Cited by 74
Cited by
Tanter, M., Bercoff, J., Athanasiou, A., Deffieux, T., Gennisson, J.-L., Montaldo, G., Muller, M., Tardivon, A., & Fink, M. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.02.002 · Cited by 733
Self-citationMagnetic Resonance Elastography for the Noninvasive Staging of Liver Fibrosis
Huwart, L., Sempoux, C., Vicaut, E., Salameh, N., Annet, L., Danse, E., Peeters, F., ter Beek, L. C., Rahier, J., Sinkus, R., et al. (2008) · Gastroenterology · doi:10.1053/j.gastro.2008.03.076 · Cited by 731
Self-citationMagnetic resonance elastography: A review
Mariappan, Y. K., Glaser, K. J., & Ehman, R. L. (2010) · Clinical Anatomy · doi:10.1002/ca.21006 · Cited by 680
An Overview of Elastography-An Emerging Branch of Medical Imaging
Sarvazyan, A., J. Hall, T., W. Urban, M., Fatemi, M., R. Aglyamov, S., & S. Garra, B. (2011) · Current Medical Imaging Reviews · doi:10.2174/157340511798038684 · Cited by 428
In vivo brain viscoelastic properties measured by magnetic resonance elastography
Green, M. A., Bilston, L. E., & Sinkus, R. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1254 · Cited by 418
Self-citation
Metadata
- Authors
- Sinkus, R., Tanter, M., Catheline, S., Lorenzen, J., Kuhl, C., Sondermann, E., & Fink, M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2005-01-27
- Volume
- 53
- Issue
- 2
- Pages
- 372-387
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2023412716
- Cited by
- 380
- References
- 21
- FWCI
- 11.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.