Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 302

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Practical approaches to the evaluation of signal‐to‐noise ratio performance with parallel imaging: Application with cardiac imaging and a 32‐channel cardiac coil

Reeder, Scott B., Wintersperger, Bernd J., Dietrich, Olaf, Lanz, Titus, Greiser, Andreas, Reiser, Maximilian F., Glazer, Gary M., Schoenberg, Stefan O.·2005·Magnetic Resonance in Medicine

Abstract

In this work, two practical methods for the measurement of signal‐to‐noise‐ratio (SNR) performance in parallel imaging are described. Phantoms and human studies were performed with a 32‐channel cardiac coil in the context of ultrafast cardiac CINE imaging at 1.5 T using steady‐state free precession (SSFP) and TSENSE. SNR and g‐factor phantom measurements using a “multiple acquisition” method were compared to measurements from a “difference method”. Excellent agreement was seen between the two methods, and the g‐factor shows qualitative agreement with theoretical predictions from the literature. Examples of high temporal (42.6 ms) and spatial (2.1 × 2.1 × 8 mm 3) resolution cardiac CINE SSFP images acquired from human volunteers using TSENSE are shown for acceleration factors up to 7. Image quality agrees qualitatively with phantom SNR measurements, suggesting an optimum acceleration of 4. With this acceleration, a cardiac function study consisting of 6 image planes (3 short‐axis views, 3 long‐axis views) was obtained in an 18‐heartbeat breath‐hold. Magn Reson Med, 2005. © 2005 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.20636

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 302

Metadata

Authors
Reeder, S. B., Wintersperger, B. J., Dietrich, O., Lanz, T., Greiser, A., Reiser, M. F., Glazer, G. M., & Schoenberg, S. O.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2005-08-08
Volume
54
Issue
3
Pages
748-754
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2065940750
Cited by
302
References
17
FWCI
15.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.