The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
In vivo detection of single cells by MRI
Abstract
The use of high‐relaxivity, intracellular contrast agents has enabled MRI monitoring of cell migration through and homing to various tissues, such as brain, spinal cord, heart, and muscle. Here it is shown that MRI can detect single cells in vivo, homing to tissue, following cell labeling and transplantation. Primary mouse hepatocytes were double‐labeled with green fluorescent 1.63‐μm iron oxide particles and red fluorescent endosomal labeling dye, and injected into the spleens of recipient mice. This is a common hepatocyte transplantation paradigm in rodents whereby hepatocytes migrate from the spleen to the liver as single cells. One month later the animals underwent in vivo MRI and punctuated, dark contrast regions were detected scattered through the livers. MRI of perfused, fixed samples and labeled hepatocyte phantoms in combination with histological evaluation confirmed the presence of dispersed single hepatocytes grafted into the livers. Appropriate controls were used to determine whether the observed contrast could have been due to dead cells or free particles, and the results confirmed that the contrast was due to disperse, single cells. Detecting single cells in vivo opens the door to a number of experiments, such as monitoring rare cellular events, assessing the kinetics of stem cell homing, and achieving early detection of metastases. Magn Reson Med, 2006. Published 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In vivo cancer targeting and imaging with semiconductor quantum dots
Gao, X., Cui, Y., Levenson, R. M., Chung, L. W. K., & Nie, S. (2004) · Nature Biotechnology · doi:10.1038/nbt994 · Cited by 4,772
Principles of Nuclear Magnetic Resonance Microscopy
Callaghan, P. T. (1991) · doi:10.1093/oso/9780198539445.001.0001 · Cited by 3,599
Lewin, M., Carlesso, N., Tung, C.-H., Tang, X.-W., Cory, D., Scadden, D. T., & Weissleder, R. (2000) · Nature Biotechnology · doi:10.1038/74464 · Cited by 1,716
Principles of Nuclear Magnetic Resonance Microscopy
Pfeifer, H. (1992) · Zeitschrift für Physikalische Chemie · doi:10.1524/zpch.1992.176.part_1.132 · Cited by 1,376
Theory of NMR signal behavior in magnetically inhomogeneous tissues: The static dephasing regime
Yablonskiy, D. A., & Haacke, E. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320610 · Cited by 1,198
Hoehn, M., Küstermann, E., Blunk, J., Wiedermann, D., Trapp, T., Wecker, S., Föcking, M., Arnold, H., Hescheler, J., Fleischmann, B. K., et al. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.242435499 · Cited by 707
Frank, J. A., Miller, B. R., Arbab, A. S., Zywicke, H. A., Jordan, E. K., Lewis, B. K., Bryant, L. H., & Bulte, J. W. M. (2003) · Radiology · doi:10.1148/radiol.2281020638 · Cited by 643
Bulte, J. W. M., Zhang, S.-C., van Gelderen, P., Herynek, V., Jordan, E. K., Duncan, I. D., & Frank, J. A. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.26.15256 · Cited by 531
MRI detection of single particles for cellular imaging
Shapiro, E. M., Skrtic, S., Sharer, K., Hill, J. M., Dunbar, C. E., & Koretsky, A. P. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403918101 · Cited by 497
Self-citationSerial Cardiac Magnetic Resonance Imaging of Injected Mesenchymal Stem Cells
Hill, J. M., Dick, A. J., Raman, V. K., Thompson, R. B., Yu, Z.-X., Hinds, K. A., Pessanha, B. S. S., Guttman, M. A., Varney, T. R., Martin, B. J., et al. (2003) · Circulation · doi:10.1161/01.cir.0000084537.66419.7a · Cited by 458
Hinds, K. A., Hill, J. M., Shapiro, E. M., Laukkanen, M. O., Silva, A. C., Combs, C. A., Varney, T. R., Balaban, R. S., Koretsky, A. P., & Dunbar, C. E. (2003) · Blood · doi:10.1182/blood-2002-12-3669 · Cited by 401
Self-citationPonder, K. P., Gupta, S., Leland, F., Darlington, G., Finegold, M., DeMayo, J., Ledley, F. D., Chowdhury, J. R., & Woo, S. L. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.4.1217 · Cited by 369
(2003) · PubMed · Cited by 357
Zhao, M., Kircher, M. F., Josephson, L., & Weissleder, R. (2002) · Bioconjugate Chemistry · doi:10.1021/bc0255236 · Cited by 319
Sizing it up: Cellular MRI using micron‐sized iron oxide particles
Shapiro, E. M., Skrtic, S., & Koretsky, A. P. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20342 · Cited by 288
Self-citationDetection of Single Mammalian Cells by High-Resolution Magnetic Resonance Imaging
Dodd, S. J., Williams, M., Suhan, J. P., Williams, D. S., Koretsky, A. P., & Ho, C. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77182-1 · Cited by 265
Self-citationAnderson, S. A., Glod, J., Arbab, A. S., Noel, M., Ashari, P., Fine, H. A., & Frank, J. A. (2005) · Blood · doi:10.1182/blood-2004-06-2222 · Cited by 254
Application of the static dephasing regime theory to superparamagnetic iron‐oxide loaded cells
Bowen, C. V., Zhang, X., Saab, G., Gareau, P. J., & Rutt, B. K. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10192 · Cited by 226
Imaging single mammalian cells with a 1.5 T clinical MRI scanner
Foster‐Gareau, P., Heyn, C., Alejski, A., & Rutt, B. K. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10417 · Cited by 207
Measuring transferrin receptor gene expression by NMR imaging
Moore, A., Basilion, J. P., Chiocca, E. A., & Weissleder, R. (1998) · Biochimica et Biophysica Acta (BBA) - Molecular Cell Research · doi:10.1016/s0167-4889(98)00002-0 · Cited by 174
Ahrens, E. T., Feili‐Hariri, M., Xu, H., Genove, G., & Morel, P. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10465 · Cited by 168
Hepatocyte suspensions and cultures as tools in experimental carcinogenesis
Seglen, P. O. (1979) · Journal of Toxicology and Environmental Health · doi:10.1080/15287397909529766 · Cited by 120
Fox, I. J., & Chowdhury, J. R. (2004) · American Journal of Transplantation · doi:10.1111/j.1600-6135.2004.0340.x · Cited by 117
Zhang, Y., Dodd, S. J., Hendrich, K. S., Williams, M., & Ho, C. (2000) · Kidney International · doi:10.1046/j.1523-1755.2000.00286.x · Cited by 91
Pirko, I., Johnson, A. J., Ćirić, B., Gamez, J. D., Macura, S. I., Pease, L. R., & Rodriguez, M. (2003) · The FASEB Journal · doi:10.1096/fj.02-1124fje · Cited by 82
Immunospecific NMR contrast agents
Renshaw, P. F., Owen, C. S., Evans, A. E., & LEIGH, J. S. J. (1986) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(86)91045-3 · Cited by 64
Therapeutic potential of hepatocyte transplantation
Gupta, S. K., & Chowdhury, J. R. (2002) · Seminars in Cell and Developmental Biology · doi:10.1016/s1084952102001325 · Cited by 63
Noninvasive monitoring of stem cell transfer for muscle disorders
Walter, G. A., Cahill, K. S., Huard, J., et al. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10684 · Cited by 58
Cited by
Recent advances in iron oxide nanocrystal technology for medical imaging☆
COROT, C., ROBERT, P., IDEE, J., & PORT, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.013 · Cited by 1,465
Challenges for Molecular Magnetic Resonance Imaging
Terreno, E., Castelli, D. D., Viale, A., & Aime, S. (2010) · Chemical Reviews · doi:10.1021/cr100025t · Cited by 855
Villaraza, A. J. L., Bumb, A., & Brechbiel, M. W. (2010) · Chemical Reviews · doi:10.1021/cr900232t · Cited by 632
Nanoplatforms for Targeted Molecular Imaging in Living Subjects
Cai, W., & Chen, X. (2007) · Small · doi:10.1002/smll.200700351 · Cited by 563
Size, charge and concentration dependent uptake of iron oxide particles by non-phagocytic cells
Thorek, D. L. J., & Tsourkas, A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.05.015 · Cited by 370
Metadata
- Authors
- Shapiro, E. M., Sharer, K., Skrtic, S., & Koretsky, A. P.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2006-01-13
- Volume
- 55
- Issue
- 2
- Pages
- 242-249
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2093746762
- Cited by
- 378
- References
- 28
- FWCI
- 26.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.