CoChat

Proton MRS of the unilateral substantia nigra in the human brain at 4 tesla: Detection of high GABA concentrations

Open access
Öz, Gülin, Terpstra, Melissa, Tkáč, Ivan, Aia, Pratibha, Lowary, Jodi, Tuite, Paul J., Gruetter, Rolf · 2006 · Magnetic Resonance in Medicine
Cited by 106

The DOI matches its Crossref record.

Abstract

Parkinson's disease (PD) is characterized by loss of dopaminergic neurons in the substantia nigra (SN), the cause of which is unknown. Characterization of early SN pathology could prove beneficial in the treatment and diagnosis of PD. The present study shows that with the use of short‐echo (5 ms) Stimulated‐Echo Acquisition Mode (STEAM) spectroscopy and LCModel, a neurochemical profile consisting of 10 metabolites, including γ‐aminobutyric acid (GABA), glutamate (Glu), and glutathione (GSH), can be measured from the unilateral SN at 4 tesla. The neurochemical profile of the SN is unique and characterized by a fourfold higher GABA/Glu ratio compared to the cortex, in excellent agreement with established neurochemistry. The presence of elevated GABA levels in SN was validated with the use of editing, suggesting that partial volume effects were greatly reduced. These findings establish the feasibility of obtaining a neurochemical profile of the unilateral human SN by single‐voxel spectroscopy in small volumes. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.20761

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Öz, G., Terpstra, M., Tkáč, I., Aia, P., Lowary, J., Tuite, P. J., & Gruetter, R.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2006-01-11
Volume
55
Issue
2
Pages
296-301
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2109548318
Cited by
106
References
0
FWCI
6.05
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.