CoChat

Reducing susceptibility artifacts in fMRI using volume‐selective z‐shim compensation

Du, Yiping P., Dalwani, Manish, Wylie, Korey, Claus, Eric, Tregellas, Jason R. · 2007 · Magnetic Resonance in Medicine
Cited by 64

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Susceptibility‐induced magnetic field gradients (SFGs) can result in severe signal loss in the orbitofrontal cortex (OFC) in gradient‐echo‐based functional MRI (fMRI) studies. Although conventional z‐shim techniques can effectively recover the MRI signal in this region, the substantial penalty in imaging time hampers their use in routine fMRI studies. A modified z‐shim technique with high imaging efficiency is presented in this study. In this technique, z‐shim compensations are applied only to a selective volume where the susceptibility artifact is severe. The results of an fMRI study (N = 6) demonstrate the feasibility of detecting the OFC activation with z‐shim in whole‐brain fMRI studies at a temporal resolution of 2 s. Magn Reson Med 57:396–404, 2007. © 2007 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.21150

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 32

  1. 10.1002/mrm.1910060412 · DOI · Paper page
  2. 10.1006/nimg.1997.0289 · DOI · Paper page
  3. 10.1002/1522-2594(200010)44:4<525::AID-MRM5>3.0.CO;2-L · DOI · Paper page
  4. 10.1006/nimg.2001.1005 · DOI
  5. 10.1002/mrm.1222 · DOI · Paper page
  6. 10.1002/mrm.20016 · DOI · Paper page
  7. 10.1002/mrm.10298 · DOI · Paper page
  8. 10.1002/mrm.10626 · DOI
  9. 10.1002/mrm.20365 · DOI · Paper page
  10. 10.1002/jmri.1880050622 · DOI · Paper page
  11. 10.1002/mrm.1910370304 · DOI · Paper page
  12. 10.1002/mrm.1910390310 · DOI · Paper page
  13. 10.1002/(SICI)1522-2594(199907)42:1<110::AID-MRM15>3.0.CO;2-3 · DOI · Paper page
  14. 10.1006/nimg.2000.0583 · DOI
  15. 10.1016/S0730-725X(00)00199-5 · DOI
  16. 10.1002/mrm.10219 · DOI
  17. 10.1002/(SICI)1522-2594(199908)42:2<290::AID-MRM11>3.0.CO;2-N · DOI · Paper page
  18. 10.1002/mrm.1205 · DOI · Paper page
  19. 10.1002/mrm.10680 · DOI · Paper page
  20. 10.1002/mrm.1910360509 · DOI
  21. 10.1016/S0730-725X(02)00507-6 · doi:10.1016/s0730-725x(02)00507-6
  22. DuYP.Whole brain fMRI with steady state z‐shimming at selected slices. In: Proceedings of the 9th Annual Meeting of ISMRM Glasgow Scotland 2001(Abstract 1231).
  23. DuYP.Image blurring in fMRI with z‐shim. In: Proceedings of the 9th Annual Meeting of ISMRM Glasgow Scotland 2001(Abstract 1232).
  24. HeberleinK HuX.Improved shim by subject head positioning. In: Proceedings of the 9th Annual Meeting of ISMRM Glasgow Scotland 2001(Abstract 1157).
  25. 10.1002/mrm.10267 · DOI · Paper page
  26. 10.1006/nimg.2001.0978 · DOI · Paper page
  27. Brett M, 2002, Region of interest analysis using an SPM toolbox, NeuroImage, 16, 372
  28. 10.1016/S1053-8119(03)00096-X · DOI · Paper page
  29. 10.1006/nimg.2002.1172 · DOI
  30. 10.1002/nbm.1940070108 · DOI · Paper page
  31. 10.1006/nimg.1996.0056 · DOI
  32. 10.1002/mrm.1253 · DOI

Cited by

See all 64

Metadata

Authors
Du, Y. P., Dalwani, M., Wylie, K., Claus, E., & Tregellas, J. R.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2007-01-26
Volume
57
Issue
2
Pages
396-404
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2101411145
Cited by
64
References
3
FWCI
3.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.