The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Fat quantification with IDEAL gradient echo imaging: Correction of bias from T1 and noise
Open accessAbstract
Quantification of hepatic steatosis is a significant unmet need for the diagnosis and treatment of patients with nonalcoholic fatty liver disease (NAFLD). MRI is capable of separating water and fat signals in order to quantify fatty infiltration of the liver (hepatic steatosis). Unfortunately, fat signal has confounding T1 effects and the nonzero mean noise in low signal‐to‐noise ratio (SNR) magnitude images can lead to incorrect estimation of the true lipid percentage. In this study, the effects of bias from T1 effects and image noise were investigated. An oil/water phantom with volume fat‐fractions ranging linearly from 0% to 100% was designed and validated using a spoiled gradient echo (SPGR) sequence in combination with a chemical‐shift based fat‐water separation method known as iterative decomposition of water and fat with echo asymmetry and least squares estimation (IDEAL). We demonstrated two approaches to reduce the effects of T1: small flip angle (flip angle) and dual flip angle methods. Both methods were shown to effectively minimize deviation of the measured fat‐fraction from its true value. We also demonstrated two methods to reduce noise bias: magnitude discrimination and phase‐constrained reconstruction. Both methods were shown to reduce this noise bias effectively from 15% to less than 1%. Magn Reson Med 58:354–364, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonalcoholic Fatty Liver Disease
Marchesini, G., Brizi, M., Bianchi, G., Tomassetti, S., Bugianesi, E., Lenzi, M., McCullough, A. J., Natale, S., Forlani, G., & Melchionda, N. (2001) · Diabetes · doi:10.2337/diabetes.50.8.1844 · Cited by 2,581
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276
Sampling Variability of Liver Biopsy in Nonalcoholic Fatty Liver Disease
Ratziu, V., Charlotte, F., Heurtier, A., Gombert, S., Giral, P., Bruckert, E., Grimaldi, A., Capron, F., & Poynard, T. (2005) · Gastroenterology · doi:10.1053/j.gastro.2005.03.084 · Cited by 2,106
Bravo, A. A., Sheth, S. G., & Chopra, S. (2001) · New England Journal of Medicine · doi:10.1056/nejm200102153440706 · Cited by 2,041
Fatty liver hepatitis (steatohepatitis) and obesity: an autopsy study with analysis of risk factors.
Wanless, I. R., & Lentz, J. S. (1990) · Hepatology · doi:10.1002/hep.1840120505 · Cited by 1,191
Chitturi, S., Abeygunasekera, S., Farrell, G. C., Holmes-Walker, J., Hui, J. M., Fung, C., Karim, R., Lin, R., Samarasinghe, D., Liddle, C., et al. (2002) · Hepatology · doi:10.1053/jhep.2002.30692 · Cited by 1,122
Barrett, H. H., Myers, K. J., & Rathee, S. (2004) · Medical Physics · doi:10.1118/1.1677252 · Cited by 1,065
Measurement of signal intensities in the presence of noise in MR images
Henkelman, R. M. (1985) · Medical Physics · doi:10.1118/1.595711 · Cited by 1,017
de Bazelaire, C. M. J., Duhamel, G. D., Rofsky, N. M., & Alsop, D. C. (2004) · Radiology · doi:10.1148/radiol.2303021331 · Cited by 792
Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state
Deoni, S. C. L., Rutt, B. K., & Peters, T. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10407 · Cited by 744
Cited by
Noninvasive assessment of liver disease in patients with nonalcoholic fatty liver disease
Castera, L., Friedrich-Rust, M., & Loomba, R. (2019) · Gastroenterology · doi:10.1053/j.gastro.2018.12.036 · Cited by 1,494
Quantitative assessment of liver fat with magnetic resonance imaging and spectroscopy
Reeder, S. B., Cruite, I., Hamilton, G., & Sirlin, C. B. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22580 · Cited by 822
Self-citationSchwenzer, N. F., Springer, F., Schraml, C., Stefan, N., Machann, J., & Schick, F. (2009) · Journal of Hepatology · doi:10.1016/j.jhep.2009.05.023 · Cited by 749
Yu, H., Shimakawa, A., McKenzie, C. A., Brodsky, E., Brittain, J. H., & Reeder, S. B. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21737 · Cited by 694
Self-citationNoninvasive, Quantitative Assessment of Liver Fat by MRI‐PDFF as an Endpoint in NASH Trials
Caussy, C., Reeder, S. B., Sirlin, C. B., & Loomba, R. (2018) · Hepatology · doi:10.1002/hep.29797 · Cited by 563
Self-citationNoureddin, M., Lam, J., Peterson, M. R., Middleton, M., Hamilton, G., Le, T.-A., Bettencourt, R., Changchien, C., Brenner, D. A., Sirlin, C., et al. (2013) · Hepatology · doi:10.1002/hep.26455 · Cited by 550
Tang, A., Tan, J., Sun, M., Hamilton, G., Bydder, M., Wolfson, T., Gamst, A. C., Middleton, M., Brunt, E. M., Loomba, R., et al. (2013) · Radiology · doi:10.1148/radiol.12120896 · Cited by 528
Proton density fat‐fraction: A standardized mr‐based biomarker of tissue fat concentration
Reeder, S. B., Hu, H. H., & Sirlin, C. B. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23741 · Cited by 501
Self-citationSchwimmer, J. B., Dunn, W., Norman, G. J., Pardee, P. E., Middleton, M. S., Kerkar, N., & Sirlin, C. B. (2010) · Gastroenterology · doi:10.1053/j.gastro.2009.12.052 · Cited by 498
Loomba, R., Wolfson, T., Ang, B., Hooker, J., Behling, C., Peterson, M., Valasek, M., Lin, G., Brenner, D., Gamst, A., et al. (2014) · Hepatology · doi:10.1002/hep.27362 · Cited by 489
Heritability of Nonalcoholic Fatty Liver Disease
Schwimmer, J. B., Celedon, M. A., Lavine, J. E., Salem, R., Campbell, N., Schork, N. J., Shiehmorteza, M., Yokoo, T., Chavez, A., Middleton, M. S., et al. (2009) · Gastroenterology · doi:10.1053/j.gastro.2009.01.050 · Cited by 466
Meisamy, S., Hines, C. D. G., Hamilton, G., Sirlin, C. B., McKenzie, C. A., Yu, H., Brittain, J. H., & Reeder, S. B. (2011) · Radiology · doi:10.1148/radiol.10100708 · Cited by 382
Self-citationFat and water magnetic resonance imaging
Bley, T. A., Wieben, O., François, C. J., Brittain, J. H., & Reeder, S. B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21895 · Cited by 372
Self-citationQuantification of Liver Fat with Magnetic Resonance Imaging
Reeder, S. B., & Sirlin, C. B. (2010) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2010.08.013 · Cited by 342
Self-citationvan Werven, J. R., Marsman, H. A., Nederveen, A. J., Smits, N. J., ten Kate, F. J., van Gulik, T. M., & Stoker, J. (2010) · Radiology · doi:10.1148/radiol.10091790 · Cited by 329
Quantification of liver fat content with CT and MRI: state of the art
Starekova, J., Hernando, D., Pickhardt, P. J., & Reeder, S. B. (2021) · Radiology · doi:10.1148/radiol.2021204288 · Cited by 320
Yokoo, T., Bydder, M., Hamilton, G., Middleton, M. S., Gamst, A. C., Wolfson, T., Hassanein, T., Patton, H. M., Lavine, J. E., Schwimmer, J. B., et al. (2009) · Radiology · doi:10.1148/radiol.2511080666 · Cited by 303
Estimation of Hepatic Proton-Density Fat Fraction by Using MR Imaging at 3.0 T
Yokoo, T., Shiehmorteza, M., Hamilton, G., Wolfson, T., Schroeder, M. E., Middleton, M. S., Bydder, M., Gamst, A. C., Kono, Y., Kuo, A., et al. (2011) · Radiology · doi:10.1148/radiol.10100659 · Cited by 290
Quantitative MRI and spectroscopy of bone marrow
Karampinos, D. C., Ruschke, S., Dieckmeyer, M., Diefenbach, M., Franz, D., Gersing, A. S., Krug, R., & Baum, T. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25769 · Cited by 285
Fatty Liver Disease: MR Imaging Techniques for the Detection and Quantification of Liver Steatosis
Cassidy, F. H., Yokoo, T., Aganovic, L., Hanna, R. F., Bydder, M., Middleton, M. S., Hamilton, G., Chavez, A. D., Schwimmer, J. B., & Sirlin, C. B. (2009) · RadioGraphics · doi:10.1148/rg.291075123 · Cited by 271
Lin, S. C., Heba, E., Wolfson, T., Ang, B., Gamst, A., Han, A., Erdman, J. W., O’Brien, W. D., Andre, M. P., Sirlin, C. B., et al. (2015) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2014.11.027 · Cited by 254
Patel, N. S., Doycheva, I., Peterson, M. R., Hooker, J., Kisselva, T., Schnabl, B., Seki, E., Sirlin, C. B., & Loomba, R. (2015) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2014.08.039 · Cited by 173
Pooler, B. D., Wiens, C. N., McMillan, A., Artz, N. S., Schlein, A., Covarrubias, Y., Hooker, J., Schwimmer, J. B., Funk, L. M., Campos, G. M., et al. (2019) · Radiology · doi:10.1148/radiol.2018181134 · Cited by 37
Self-citationLiver Fat Quantification by Dual-echo MR Imaging Outperforms Traditional Histopathological Analysis
Fischer, M. A., Raptis, D. A., Montani, M., Graf, R., Clavien, P.-A., Nanz, D., Alkadhi, H., & Scheffel, H. (2012) · Academic Radiology · doi:10.1016/j.acra.2012.05.009 · Cited by 25
Metadata
- Authors
- Liu, C., McKenzie, C. A., Yu, H., Brittain, J. H., & Reeder, S. B.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2007-07-24
- Volume
- 58
- Issue
- 2
- Pages
- 354-364
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2069846825
- Cited by
- 477
- References
- 33
- FWCI
- 10.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.