Positive contrast visualization of iron oxide‐labeled stem cells using inversion‐recovery with ON‐resonant water suppression (IRON)

Open access
Stuber, Matthias, Gilson, Wesley D., Schär, Michael, Kedziorek, Dorota A., Hofmann, Lawrence V., Shah, Saurabh, Vonken, Evert‐Jan, Bulte, Jeff W.M., Kraitchman, Dara L.·2007·Magnetic Resonance in Medicine

Abstract

In proton magnetic resonance imaging (MRI) metallic substances lead to magnetic field distortions that often result in signal voids in the adjacent anatomic structures. Thus, metallic objects and superparamagnetic iron oxide (SPIO)‐labeled cells appear as hypointense artifacts that obscure the underlying anatomy. The ability to illuminate these structures with positive contrast would enhance noninvasive MR tracking of cellular therapeutics. Therefore, an MRI methodology that selectively highlights areas of metallic objects has been developed. Inversion‐recovery with ON‐resonant water suppression (IRON) employs inversion of the magnetization in conjunction with a spectrally‐selective on‐resonant saturation prepulse. If imaging is performed after these prepulses, positive signal is obtained from off‐resonant protons in close proximity to the metallic objects. The first successful use of IRON to produce positive contrast in areas of metallic spheres and SPIO‐labeled stem cells in vitro and in vivo is presented. Magn Reson Med 58:1072–1077, 2007. © 2007 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.21399

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 215

Metadata

Authors
Stuber, M., Gilson, W. D., Schär, M., Kedziorek, D. A., Hofmann, L. V., Shah, S., Vonken, E., Bulte, J. W. M., & Kraitchman, D. L.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2007-10-29
Volume
58
Issue
5
Pages
1072-1077
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2088435744
Cited by
215
References
1
FWCI
19.38
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Positive contrast visualization of iron oxide‐labeled stem cells using inversion‐recovery with ON‐resonant water suppression (IRON). https://app.cochat.ai/papers/10.1002/mrm.21399
The paper
Stuber, M., Gilson, W. D., Schär, M., Kedziorek, D. A., Hofmann, L. V., Shah, S., Vonken, E., Bulte, J. W. M., & Kraitchman, D. L. (2007). Positive contrast visualization of iron oxide‐labeled stem cells using inversion‐recovery with ON‐resonant water suppression (IRON). Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21399

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.