The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
SEMAC: Slice encoding for metal artifact correction in MRI
Open accessAbstract
Magnetic resonance imaging (MRI) near metallic implants remains an unmet need because of severe artifacts, which mainly stem from large metal‐induced field inhomogeneities. This work addresses MRI near metallic implants with an innovative imaging technique called “Slice Encoding for Metal Artifact Correction” (SEMAC). The SEMAC technique corrects metal artifacts via robust encoding of each excited slice against metal‐induced field inhomogeneities. The robust slice encoding is achieved by extending a view‐angle‐tilting (VAT) spin‐echo sequence with additional z‐phase encoding. Although the VAT compensation gradient suppresses most in‐plane distortions, the z‐phase encoding fully resolves distorted excitation profiles that cause through‐plane distortions. By positioning all spins in a region‐of‐interest to their actual spatial locations, the through‐plane distortions can be corrected by summing up the resolved spins in each voxel. The SEMAC technique does not require additional hardware and can be deployed to the large installed base of whole‐body MRI systems. The efficacy of the SEMAC technique in eliminating metal‐induced distortions with feasible scan times is validated in phantom and in vivo spine and knee studies. Magn Reson Med 62:66–76, 2009. © 2009 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Self-citationSENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Diagnosis of Bone and Joint Disorders
RESNICK, D. L. (1987) · UCLA - Biblioteca de Ciencias de la Salud · Cited by 2,011
KURTZ, S., MOWAT, F., ONG, K., CHAN, N., LAU, E., & HALPERN, M. (2005) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200507000-00010 · Cited by 1,347
Diagnosis of Bone and Joint Disorders
Wilson, D. (2003) · Clinical Radiology · doi:10.1016/s0009-9260(02)00578-0 · Cited by 753
Homodyne detection in magnetic resonance imaging
Noll, D. C., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.79473 · Cited by 514
Susceptibility artefacts in NMR imaging
Lüdeke, K. M., Röschmann, P., & Tischler, R. (1985) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(85)90397-2 · Cited by 445
Busse, R. F., Hariharan, H., Vu, A., & Brittain, J. H. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20863 · Cited by 335
Total inhomogeneity correction including chemical shifts and susceptibility by view angle tilting
Cho, Z. H., Kim, D. J., & Kim, Y. K. (1988) · Medical Physics · doi:10.1118/1.596162 · Cited by 217
Metal Artifact Reduction Sequence: Early Clinical Applications
Olsen, R. V., Munk, P. L., Lee, M. J., Janzen, D. L., MacKay, A. L., Xiang, Q.-S., & Masri, B. (2000) · RadioGraphics · doi:10.1148/radiographics.20.3.g00ma10699 · Cited by 208
3D z-shim method for reduction of susceptibility effects in BOLD fMRI
Glover, G. H. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199908)42:2<290::aid-mrm11>3.0.co;2-n · Cited by 160
Yang, Q., Williams, G. D., Demeure, R., Mosher, T. J., & Smith, M. B. H. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390310 · Cited by 125
Composite image formation inz-shimmed functional MR imaging
Constable, R. T., & Spencer, D. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199907)42:1<110::aid-mrm15>3.0.co;2-3 · Cited by 119
Reduction of blurring in view angle tilting MRI
Butts, K., Pauly, J. M., & Gold, G. E. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20375 · Cited by 108
Self-citationQuantitative evaluation of metal artifact reduction techniques
Kolind, S., MacKay, A. L., Munk, P. L., & Xiang, Q. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20144 · Cited by 87
3 Principles of Magnetic Resonance Imaging
Tanttu, J. I., & SEPPONEN, R. E. (1996) · Cited by 79
Ramos‐Cabrer, P., van Duynhoven, J., van der Toorn, A., & Nicolay, K. (2004) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.01.061 · Cited by 68
Metal artifacts caused by gradient switching
Graf, H., Steidle, G., Martirosian, P., Lauer, U. A., & Schick, F. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20524 · Cited by 42
Cited by
Metal-Induced Artifacts in MRI
Hargreaves, B. A., Worters, P. W., Pauly, K. B., Pauly, J. M., Koch, K. M., & Gold, G. E. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.11.7364 · Cited by 559
Self-citationRadiotherapy planning using MRI
Schmidt, M. A., & Payne, G. S. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/22/r323 · Cited by 357
Rapid Musculoskeletal MRI in 2021: Clinical Application of Advanced Accelerated Techniques
Fritz, J., Guggenberger, R., & Grande, F. D. (2021) · American Journal of Roentgenology · doi:10.2214/ajr.20.22902 · Cited by 121
Metadata
- Authors
- Lu, W., Pauly, K. B., Gold, G. E., Pauly, J. M., & Hargreaves, B. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2009-03-06
- Volume
- 62
- Issue
- 1
- Pages
- 66-76
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2082087152
- Cited by
- 392
- References
- 19
- FWCI
- 10.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.