The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Whole brain susceptibility mapping using compressed sensing
Open accessAbstract
The derivation of susceptibility from image phase is hampered by the ill‐conditioned filter inversion in certain k‐space regions. In this article, compressed sensing is used to compensate for the k‐space regions where direct filter inversion is unstable. A significantly lower level of streaking artifacts is produced in the resulting susceptibility maps for both simulated and in vivo data sets compared to outcomes obtained using the direct threshold method. It is also demonstrated that the compressed sensing based method outperforms regularization based methods. The key difference between the regularized inversions and compressed sensing compensated inversions is that, in the former case, the entire k‐space spectrum estimation is affected by the ill‐conditioned filter inversion in certain k‐space regions, whereas in the compressed sensing based method only the ill‐conditioned k‐space regions are estimated. In the susceptibility map calculated from the phase measurement obtained using a 3T scanner, not only are the iron‐rich regions well depicted, but good contrast between white and gray matter interfaces that feature a low level of susceptibility variations are also obtained. The correlation between the iron content and the susceptibility levels in iron‐rich deep nucleus regions is studied, and strong linear relationships are observed which agree with previous findings. Magn Reson Med, 2011. © 2011 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,703
Nonlinear total variation based noise removal algorithms
Rudin, L. I., Osher, S., & Fatemi, E. (1992) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(92)90242-f · Cited by 15,704
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Lustig, M., Donoho, D. L., Santos, J. M., & Pauly, J. M. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914728 · Cited by 2,246
Sparsity and incoherence in compressive sampling
Candès, E., & Romberg, J. (2007) · Inverse Problems · doi:10.1088/0266-5611/23/3/008 · Cited by 2,075
Sidky, E. Y., & Pan, X. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/021 · Cited by 1,995
Susceptibility weighted imaging (SWI)
Haacke, E. M., Xu, Y., Cheng, Y. N., & Reichenbach, J. R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20198 · Cited by 1,582
The effect of age on the non-haemin iron in the human brain
Hallgren, B., & Sourander, P. (1958) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1958.tb12607.x · Cited by 1,427
Susceptibility-Weighted Imaging: Technical Aspects and Clinical Applications, Part 1
Haacke, E. M., Mittal, S., Wu, Z., Neelavalli, J., & Cheng, Y.-C. N. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1400 · Cited by 1,113
DEXTER, D. T., CARAYON, A., JAVOY-AGID, F., AGID, Y., WELLS, F. R., DANIEL, S. E., LEES, A. J., JENNER, P., & MARSDEN, C. D. (1991) · Brain · doi:10.1093/brain/114.4.1953 · Cited by 1,043
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Schweser, F., Deistung, A., Lehr, B. W., & Reichenbach, J. R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.070 · Cited by 710
de Rochefort, L., Liu, T., Kressler, B., Liu, J., Spincemaille, P., Lebon, V., Wu, J., & Wang, Y. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22187 · Cited by 670
High-field MRI of brain cortical substructure based on signal phase
Duyn, J. H., van Gelderen, P., Li, T.-Q., de Zwart, J. A., Koretsky, A. P., & Fukunaga, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610821104 · Cited by 641
Quantitative susceptibility mapping of human brain reflects spatial variation in tissue composition
Li, W., Wu, B., & Liu, C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.11.088 · Cited by 624
Self-citationMagnetic susceptibility mapping of brain tissue in vivo using MRI phase data
Shmueli, K., de Zwart, J. A., van Gelderen, P., Li, T., Dodd, S. J., & Duyn, J. H. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22135 · Cited by 527
Liu, T., Spincemaille, P., de Rochefort, L., Kressler, B., & Wang, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21828 · Cited by 454
Marques, J. P., & Bowtell, R. (2005) · Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering · doi:10.1002/cmr.b.20034 · Cited by 434
Salomir, R., de Senneville, B. D., & Moonen, C. T. (2003) · Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering · doi:10.1002/cmr.b.10083 · Cited by 389
Liu, C. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22482 · Cited by 325
Self-citationBiophysical mechanisms of phase contrast in gradient echo MRI
He, X., & Yablonskiy, D. A. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0904899106 · Cited by 272
Parallel imaging reconstruction using automatic regularization
Lin, F., Kwong, K. K., Belliveau, J. W., & Wald, L. L. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10718 · Cited by 266
Sensitivity of MRI resonance frequency to the orientation of brain tissue microstructure
Lee, J., Shmueli, K., Fukunaga, M., van Gelderen, P., Merkle, H., Silva, A. C., & Duyn, J. H. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910222107 · Cited by 263
Susceptibility mapping in the human brain using threshold‐based k‐space division
Wharton, S., Schäfer, A., & Bowtell, R. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22334 · Cited by 244
In Vivo Evaluation of Brain Iron in Alzheimer Disease Using Magnetic Resonance Imaging
Bartzokis, G., Sultzer, D., Cummings, J., Holt, L. E., Hance, D. B., Henderson, V. W., & Mintz, J. (2000) · Archives of General Psychiatry · doi:10.1001/archpsyc.57.1.47 · Cited by 235
Magnetic susceptibility-weighted MR phase imaging of the human brain.
Rauscher, A., Sedlacik, J., Barth, M., Mentzel, H., & Reichenbach, J. R. (2005) · PubMed Central · Cited by 227
Kressler, B., de Rochefort, L., Liu, T., Spincemaille, P., Jiang, Q., & Wang, Y. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2023787 · Cited by 220
Wharton, S., & Bowtell, R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.070 · Cited by 187
Compressed sensing for resolution enhancement of hyperpolarized 13C flyback 3D-MRSI
Hu, S., Lustig, M., Chen, A. P., Crane, J., Kerr, A., Kelley, D. A. C., Hurd, R., Kurhanewicz, J., Nelson, S. J., Pauly, J. M., et al. (2008) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2008.03.003 · Cited by 186
Chen, J. C., Hardy, P., Kucharczyk, W., Clauberg, M., Joshi, J. G., Vourlas, A., Dhar, M. S., & Henkelman, R. M. (1993) · PubMed Central · Cited by 156
Quantifying arbitrary magnetic susceptibility distributions with MR
Li, L. Z., & LEIGH, J. S. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20054 · Cited by 132
Deterministic phase unwrapping in the presence of noise
Volkov, V. V., & Zhu, Y. (2003) · Optics Letters · doi:10.1364/ol.28.002156 · Cited by 129
Griffiths, P. D., & Crossman, A. R. (1993) · Dementia and Geriatric Cognitive Disorders · doi:10.1159/000107298 · Cited by 113
Liu, T., Spincemaille, P., de Rochefort, L., Wong, R., Prince, M. R., & Wang, Y. (2010) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2010.06.011 · Cited by 70
Improving non‐contrast‐enhanced steady‐state free precession angiography with compressed sensing
Çukur, T., Lustig, M. S., & Nishimura, D. G. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21907 · Cited by 61
Cited by
Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Langkammer, C., Schweser, F., Krebs, N., Deistung, A., Goessler, W., Scheurer, E., Sommer, K., Reishofer, G., Yen, K., Fazekas, F., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.05.049 · Cited by 801
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Quantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
Liu, C., Li, W., Tong, K. A., Yeom, K. W., & Kuzminski, S. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24768 · Cited by 503
Self-citation
Metadata
- Authors
- Wu, B., Li, W., Guidon, A., & Liu, C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2011-06-10
- Volume
- 67
- Issue
- 1
- Pages
- 137-147
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2152166807
- Cited by
- 417
- References
- 36
- FWCI
- 11.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.