Effect of lanthanide ions on dynamic nuclear polarization enhancement and liquid‐state T1 relaxation
Abstract
In the dynamic nuclear polarization process, microwave irradiation facilitates exchange of polarization from a radical's unpaired electron to nuclear spins at cryogenic temperatures, increasing polarization by >10,000. Doping samples with Gd 3+ ions further increases the achievable solid‐state polarization. However, on dissolution, paramagnetic lanthanide metals can be potent relaxation agents, decreasing liquid‐state polarization. Here, the effects of lanthanide metals on the solid and liquid‐state magnetic properties of [1‐13 C]pyruvate are studied. The results show that in addition to gadolinium, holmium increases not only the achievable polarization but also the rate of polarization. Liquid‐state relaxation studies found that unlike gadolinium, holmium minimally affects T1. Additionally, results reveal that linear contrast agents dissociate in pyruvic acid, greatly reducing liquid‐state T1. Although macrocyclic agents do not readily dissociate, they yield lower solid‐state polarization. Results indicate that polarization with free lanthanides and subsequent chelation during dissolution produces the highest polarization enhancement while minimizing liquid‐state relaxation. Magn Reson Med, 2012. © 2012 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This relaxation by paramagnetic metals can be minimized by chelation of the metal during the dissolution, as was shown in the case of chelation of Gd3+ ions by diethylenetriaminepentaacetic acid (DTPA) during the dissolution process.”
From Use of paramagnetic systems to speed-up NMR data acquisition and for structural and dynamic studies (2019) · cites this paper as [167]
In the citing paper
“Paramagnetic dopants can also be effectively utilized in DNP, a process utilized to transfer polarization from the unpaired electron of a stable radical to nuclear spins, enhancing the NMR sensitivity dramatically at cryogenic temperatures [48,161–174].”
From Use of paramagnetic systems to speed-up NMR data acquisition and for structural and dynamic studies (2019) · cites this paper as [167]
In the citing paper
“Interestingly, applications of paramagnetic metals are also possible in dissolution DNP, where metals such as lanthanides, can be used to increase the polarization in solid-state, but can, due to their relaxation properties, significantly decrease liquid-state polarization[167].”
From Use of paramagnetic systems to speed-up NMR data acquisition and for structural and dynamic studies (2019) · cites this paper as [167]
In the citing paper
“Gd3+ ions could not reduce the T1 of the 13C of the pyruvate molecule in the liquid state due to the chelation with DTPA that increases Gd3+-13C distance due both to electrostatic repulsion and steric hinderance.”
From Use of paramagnetic systems to speed-up NMR data acquisition and for structural and dynamic studies (2019) · cites this paper as [167]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 29
- 10.2174/138920110792246636 · doi:10.2174/138920110792246636
- 10.1007/s00330-005-2806-x · DOI · Paper page
- 10.1158/0008-5472.CAN-08-0749 · DOI · Paper page
- 10.1002/nbm.1616 · DOI
- 10.1038/sj.bjc.6605945 · DOI
- 10.1073/pnas.1733835100 · DOI · Paper page
- 10.1007/s00723-008-0134-4 · doi:10.1007/s00723-008-0134-4
- 10.1016/j.jmr.2008.12.016 · DOI
- Waldner LF, 2010, The effects of contrast agents on hyperpolarised [1–13C]‐pyruvic acid, Proc Int Soc Magn Reson Med, 3263
- 10.1039/c002699a · doi:10.1039/c002699a
- 10.1002/mrm.1910010407 · doi:10.1002/mrm.1910010407
- Gordon J, 2011, Effect of lanthanide ions on dynamic nuclear polarization enhancement and liquid state T 1 relaxation, Proc Int Soc Magn Reson Med, 1512
- 10.1021/ja0583261 · doi:10.1021/ja0583261
- 10.1021/jp0111158 · doi:10.1021/jp0111158
- 10.1039/dt9800002151 · doi:10.1039/dt9800002151
- 10.1016/0079-6565(95)01026-2 · DOI · Paper page
- 10.1002/jmri.21966 · DOI · Paper page
- 10.1002/chem.200500129 · doi:10.1002/chem.200500129
- 10.1002/cmmi.94 · doi:10.1002/cmmi.94
- Murphy PS, 2002, The effects of paramagnetic contrast agents on metabolite protons in aqueous solution, Phys Med Biol, 47, N53
- 10.1002/cmmi.272 · doi:10.1002/cmmi.272
- 10.1002/cmr.b.20099 · DOI · Paper page
- 10.1016/0022-2364(77)90287-6 · doi:10.1016/0022-2364(77)90287-6
- 10.1002/1521-3765(20010202)7:3<600::AID-CHEM600>3.0.CO;2-H · doi:10.1002/1521-3765(20010202)7:3<600::aid-chem600>3.0.co;2-h
- 10.1002/hlca.200690186 · DOI
- 10.1016/j.ejrad.2008.01.025 · doi:10.1016/j.ejrad.2008.01.025
- 10.1021/ja9049355 · DOI
- 10.1002/mrm.22851 · DOI
- 10.1073/pnas.1733836100 · DOI · Paper page
Cited by
Use of paramagnetic systems to speed-up NMR data acquisition and for structural and dynamic studies
Kocman, V., Di Mauro, G. M., Veglia, G., & Ramamoorthy, A. (2019) · Solid State Nuclear Magnetic Resonance · doi:10.1016/j.ssnmr.2019.07.002 · Cited by 45
Metadata
- Authors
- Gordon, J. W., Fain, S. B., & Rowland, I. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2012-02-24
- Volume
- 68
- Issue
- 6
- Pages
- 1949-1954
- ISSN
- 0740-3194
- 1522-2594
- Cited by
- 39
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.