T2 shuffling: Sharp, multicontrast, volumetric fast spin‐echo imaging
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Purpose: A new acquisition and reconstruction method called T2 Shuffling is presented for volumetric fast spin‐echo (three‐dimensional [3D] FSE) imaging. T2 Shuffling reduces blurring and recovers many images at multiple T2 contrasts from a single acquisition at clinically feasible scan times (6–7 min). Theory and Methods: The parallel imaging forward model is modified to account for temporal signal relaxation during the echo train. Scan efficiency is improved by acquiring data during the transient signal decay and by increasing echo train lengths without loss in signal‐to‐noise ratio (SNR). By (1) randomly shuffling the phase encode view ordering, (2) constraining the temporal signal evolution to a low‐dimensional subspace, and (3) promoting spatio‐temporal correlations through locally low rank regularization, a time series of virtual echo time images is recovered from a single scan. A convex formulation is presented that is robust to partial voluming and radiofrequency field inhomogeneity. Results: Retrospective undersampling and in vivo scans confirm the increase in sharpness afforded by T2 Shuffling. Multiple image contrasts are recovered and used to highlight pathology in pediatric patients. A proof‐of‐principle method is integrated into a clinical musculoskeletal imaging workflow. Conclusion: The proposed T2 Shuffling method improves the diagnostic utility of 3D FSE by reducing blurring and producing multiple image contrasts from a single scan. Magn Reson Med 77:180–195, 2017. © 2016 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boyd, S., Parikh, N., Chu, E., Peleato, B., & Eckstein, J. (2011) · Foundations and Trends® in Machine Learning · doi:10.1561/2200000016 · Cited by 17,075
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Self-citationMagnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577
ESPIRiT—an eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA
Uecker, M., Lai, P., Murphy, M. J., Virtue, P., Elad, M., Pauly, J. M., Vasanawala, S. S., & Lustig, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24751 · Cited by 1,392
Self-citationVidal, R. (2011) · IEEE Signal Processing Magazine · doi:10.1109/msp.2010.939739 · Cited by 1,126
Rapid magnetic resonance quantification on the brain: Optimization for clinical usage
Warntjes, J. B. M., Leinhard, O. D., West, J., & Lundberg, P. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21635 · Cited by 500
Optimized three‐dimensional fast‐spin‐echo MRI
Mugler, J. P. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24542 · Cited by 376 · cited 1×
“[1], implicitly assuming that ftð Þ does not change over time.”
BackgroundBusse, R. F., Hariharan, H., Vu, A., & Brittain, J. H. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20863 · Cited by 335 · cited 1×
“xðrÞ5 x1ðrÞ x2ðrÞ xTðrÞ 1⁄2 T 2 C : [5]”
Compressed sensing reconstruction for magnetic resonance parameter mapping
Doneva, M., Börnert, P., Eggers, H., Stehning, C., Sénégas, J., & Mertins, A. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22483 · Cited by 326
Zhao, B., Haldar, J. P., Christodoulou, A. G., & Liang, Z.-P. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2203921 · Cited by 295
Accelerating parameter mapping with a locally low rank constraint
Zhang, T., Pauly, J. M., & Levesque, I. R. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25161 · Cited by 241
Rapid and accurate T2 mapping from multi–spin‐echo data using Bloch‐simulation‐based reconstruction
Ben‐Eliezer, N., Sodickson, D. K., & Block, K. T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25156 · Cited by 224
Gold, G. E., Busse, R. F., Beehler, C., Han, E., Brau, A. C. S., Beatty, P. J., & Beaulieu, C. F. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1208 · Cited by 191 · cited 1×
“ftðrÞ5e(2) t T2ðrÞ 12e(2) TR2T3Ts T1ðrÞ ; [2]”
Accelerated MR parameter mapping with low‐rank and sparsity constraints
Zhao, B., Lu, W., Hitchens, T. K., Lam, F., Ho, C., & Liang, Z. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25421 · Cited by 188
Sparse-View Spectral CT Reconstruction Using Spectral Patch-Based Low-Rank Penalty
Kim, K., Ye, J. C., Worstell, W. A., Ouyang, J., Rakvongthai, Y., Fakhri, G. E., & Li, Q. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2380993 · Cited by 185
Huang, C., Graff, C. G., Clarkson, E. W., Bilgin, A., & Altbach, M. I. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23128 · Cited by 175
Model-Based Iterative Reconstruction for Radial Fast Spin-Echo MRI
Block, K. T., Uecker, M., & Frahm, J. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2023119 · Cited by 173 · cited 2×
“[14], it is feasible to save the temporal coefficients only and compute arbitrary virtual echo time images in real-time.”
BackgroundSelf-citationMulticomponent T2 relaxation analysis in cartilage
Reiter, D. A., Lin, P., Fishbein, K. W., & Spencer, R. G. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21926 · Cited by 161
Model‐based nonlinear inverse reconstruction for T2 mapping using highly undersampled spin‐echo MRI
Sumpf, T. J., Uecker, M., Boretius, S., & Frahm, J. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22634 · Cited by 160 · cited 3×
“[15] uses ideas from compressed sensing to reduce sample complexity through the use of LLR regularization, the data space should be sampled incoherently with respect to the unknown (42).”
MethodInfluentialSelf-citationAccelerating MR parameter mapping using sparsity‐promoting regularization in parametric dimension
Velikina, J., Alexander, A. L., & Samsonov, A. A. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24577 · Cited by 144
Model-based iterative reconstruction for radial fast spin-echo MRI.
Block, K. T., Uecker, M., & Frahm, J. (2009) · Max Planck Institute for Plasma Physics · Cited by 131
Self-citationRoutine 3D magnetic resonance imaging of joints
Kijowski, R., & Gold, G. E. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22342 · Cited by 122 · cited 2×
“[3] is convolved in image space with the proton-density image, the approximation impacts the apparent tissue contrast and leads to blurring due to T2 decay during the acquisition (5,6).”
BackgroundMultiscale reconstruction for MR fingerprinting
Pierre, E. Y., Ma, D., Chen, Y., Badve, C. A., & Griswold, M. A. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25776 · Cited by 108
Zhang, T., Cheng, J. Y., Potnick, A., Barth, R. A., Alley, M. T., Uecker, M., Lustig, M. S., Pauly, J. M., & Vasanawala, S. S. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24551 · Cited by 105
Self-citationKecskemeti, S., Samsonov, A. A., Hurley, S. A., Dean, D., Field, A. S., & Alexander, A. L. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25674 · Cited by 87
T 2 Relaxation time quantitation differs between pulse sequences in articular cartilage
Matzat, S. J., McWalter, E. J., Kogan, F., Chen, W., & Gold, G. E. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24757 · Cited by 77
Self-citationT 2 relaxometry with indirect echo compensation from highly undersampled data
Huang, C., Bilgin, A., Barr, T., & Altbach, M. I. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24540 · Cited by 59
Accelerated whole‐brain multi‐parameter mapping using blind compressed sensing
Bhave, S., Lingala, S. G., Johnson, C. P., Magnotta, V. A., & Jacob, M. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25722 · Cited by 54
Ben‐Eliezer, N., Sodickson, D. K., Shepherd, T. M., Wiggins, G. C., & Block, K. T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25558 · Cited by 49
Sumpf, T. J., Petrovic, A., Uecker, M., et al. (2014) · Cited by 48
Self-citationVelikina, J., & Samsonov, A. A. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25513 · Cited by 47
Echo time optimization for linear combination myelin imaging
Vidarsson, L., Conolly, S. M., Lim, K. O., Gold, G. E., & Pauly, J. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20360 · Cited by 44
Fast iterative algorithm for the reconstruction of multishot non‐cartesian diffusion data
Mani, M., Jacob, M., Magnotta, V. A., & Zhong, J. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25486 · Cited by 15
Fast spin echo imaging of carotid artery dynamics
Boesen, M. E., Neto, L. A. S. M., Pulwicki, A., Yerly, J., Lebel, R. M., & Frayne, R. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25494 · Cited by 12
Cited by
Magnetic resonance multitasking for motion-resolved quantitative cardiovascular imaging
Christodoulou, A. G., Shaw, J. L., Nguyen, C., Yang, Q., Xie, Y., Wang, N., & Li, D. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0217-y · Cited by 323
Improved magnetic resonance fingerprinting reconstruction with low‐rank and subspace modeling
Zhao, B., Setsompop, K., Adalsteinsson, E., Gagoski, B., Ye, H., Ma, D., Jiang, Y., Ellen Grant, P., Griswold, M. A., & Wald, L. L. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26701 · Cited by 179
“Ratherthan directly solving a generic low-rank matrix recovery problem, we can further incorporate a temporal subspace constraint (9,11–13, 15, 17, 29 ) to which can be efficiently solved by a number of iterative numerical solvers (e.g., the conjugate gradient algorithm).”
BackgroundMethodInfluential
Metadata
- Authors
- Tamir, J. I., Uecker, M., Chen, W., Lai, P., Alley, M. T., Vasanawala, S. S., & Lustig, M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2016-01-20
- Volume
- 77
- Issue
- 1
- Pages
- 180-195
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2297755274
- Cited by
- 196
- References
- 34
- FWCI
- 10.51
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.