Multi-shot sensitivity-encoded diffusion data recovery using structured low-rank matrix completion (MUSSELS): Annihilating Filter K-Space Formulation for Multi-Shot DWI Recovery
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
PURPOSE: To introduce a novel method for the recovery of multi-shot diffusion weighted (MS-DW) images from echo-planar imaging (EPI) acquisitions. METHODS: Current EPI-based MS-DW reconstruction methods rely on the explicit estimation of the motion-induced phase maps to recover artifact-free images. In the new formulation, the k-space data of the artifact-free DWI is recovered using a structured low-rank matrix completion scheme, which does not require explicit estimation of the phase maps. The structured matrix is obtained as the lifting of the multi-shot data. The smooth phase-modulations between shots manifest as null-space vectors of this matrix, which implies that the structured matrix is low-rank. The missing entries of the structured matrix are filled in using a nuclear-norm minimization algorithm subject to the data-consistency. The formulation enables the natural introduction of smoothness regularization, thus enabling implicit motion-compensated recovery of the MS-DW data. RESULTS: Our experiments on in-vivo data show effective removal of artifacts arising from inter-shot motion using the proposed method. The method is shown to achieve better reconstruction than the conventional phase-based methods. CONCLUSION: We demonstrate the utility of the proposed method to effectively recover artifact-free images from Cartesian fully/under-sampled and partial Fourier acquired data without the use of explicit phase estimates. Magn Reson Med 78:494-507, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303 · cited 1×
“Learning shift-invariant annihilating filters from a calibration scan to recover missing k-space data in a local neighborhood is also now well-established in parallel-MRI reconstruction literature (42,43,45).”
BackgroundLe Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912 · cited 2×
“Magnetic resonance diffusion-weighted imaging (DWI) is a unique noninvasive tool used to study the micro-architecture of tissues by modeling the diffusion of water molecules in the tissue (1,2).”
MethodSpectral Analysis of Signals: The Missing Data Case
Wang, Y., Li, J., & Stoica, P. (2005) · Synthesis Lectures on Signal Processing · doi:10.1007/978-3-031-02525-9 · Cited by 2,890
ESPIRiT—an eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA
Uecker, M., Lai, P., Murphy, M. J., Virtue, P., Elad, M., Pauly, J. M., Vasanawala, S. S., & Lustig, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24751 · Cited by 1,392
Advances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211 · cited 1×
“Liu et al showed that by using an encoding function that combines the coil sensitivity with the phase information of the individual shots, the unaliased image could be recovered (40) using an iterative sensitivity encoded reconstruction algorithm [41].”
MethodSampling signals with finite rate of innovation
Vetterli, M., Marziliano, P., & Blu, T. (2002) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2002.1003065 · Cited by 1,079
(2024) · American Journal of Neuroradiology · doi:10.3174/ajnr.45-12.s8 · Cited by 890
Basic principles of diffusion-weighted imaging
Bammer, R. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00303-0 · Cited by 851 · cited 1×
“Thus for coils i , j of shot l , we have: m il ð x Þ ¼ r ð x Þ s i ð x Þ [18] m jl ð x Þ ¼ r ð x Þ s j ð x Þ : [19] Multiplying Equation [18] by s j ð x Þ and Equation [19] by s i ð x Þ and subtracting we get the following: m il ð x Þ s j ð x Þ (cid”
SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐space
Lustig, M., & Pauly, J. M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22428 · Cited by 822 · cited 1×
“Learning shift-invariant annihilating filters from a calibration scan to recover missing k-space data in a local neighborhood is also now well-established in parallel-MRI reconstruction literature (42,43,45).”
BackgroundUğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Artifacts and pitfalls in diffusion MRI
Le Bihan, D., Poupon, C., Amadon, A., & Lethimonnier, F. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20683 · Cited by 778 · cited 1×
“Hðd @1mÞ Hðd @2mÞ 2 4 3 5 |fflfflfflfflfflfflfflffl{zfflfflfflfflfflfflfflffl} Gðb mÞ b l 1⁄4 0: [12]”
(2009) · doi:10.1016/b978-0-12-374709-9.x0001-6 · Cited by 686
Uludağ, K., Müller-Bierl, B., & Uğurbil, K. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.051 · Cited by 450
Multishot diffusion‐weighted FSE using PROPELLER MRI
Pipe, J. G., Farthing, V. G., & Forbes, K. P. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10014 · Cited by 428 · cited 1×
“The equivalent unconstrained reconstruction problem can be written as [25] where l 1 and k 2 are two regularization parameters.”
BackgroundAnalysis and correction of motion artifacts in diffusion weighted imaging
Anderson, A. W., & Gore, J. C. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320313 · Cited by 393 · cited 2×
“The angular error computes the error in the primary diffusion direction (PDD) as: error ¼ acos ð ~ v ref (cid:6) ~ v us Þ (cid:5) 180 = p ; [17] where ~ v ref and ~ v us are the PDD of the reference and under-sampled data.”
BackgroundCalibrationless parallel imaging reconstruction based on structured low-rank matrix completion
Shin, P. J., Larson, P. E. Z., Ohliger, M. A., Elad, M., Pauly, J. M., Vigneron, D. B., & Lustig, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24997 · Cited by 391 · cited 1×
“Recently this idea was also extended to calibration-less parallel imaging reconstruction using structured low-rank matrix completion (31,33,35,55).”
MethodChen, N.-K., Guidon, A., Chang, H.-C., & Song, A. W. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.01.038 · Cited by 364
Bertsekas, D. P. (1976) · Automatica · doi:10.1016/0005-1098(76)90077-7 · Cited by 347
Ebisu, T., Tanaka, C., Umeda, M., Kitamura, M., Naruse, S., Higuchi, T., Ueda, S., & Sato, H. (1996) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(96)00237-8 · Cited by 347 · cited 1×
“As evident from Equation [6], for an N s -shot acquisition, there will be N s 2 columns in b U , which implies that the block-Hankel matrix H 1 ð b m Þ has a null-space of dimension (cid:7) N s , thus establishing the low-rankedness of H 1 ð b m Þ (31–34, 44 , 45 ).”
BackgroundLai, P., Ho, J. T., Chen, W. L., Hsu, S. S., Wang, J. S., Pan, H. B., & Yang, C. F. (2002) · PubMed Central · Cited by 332
Haldar, J. P. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2293974 · Cited by 326
Self‐navigated interleaved spiral (SNAILS): Application to high‐resolution diffusion tensor imaging
Liu, C., Bammer, R., Kim, D., & Moseley, M. E. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20288 · Cited by 247
Jin, K. H., Lee, D., & Ye, J. C. (2016) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2016.2601296 · Cited by 245
Diffusion‐weighted interleaved echo‐planar imaging with a pair of orthogonal navigator echoes
Butts, K., de Crespigny, A., Pauly, J. M., & Moseley, M. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350518 · Cited by 244 · cited 2×
“Methods to estimate the phase fall into two categories: (i) methods that rely on navigator scans [16, (20–22)] and (ii) methods that estimates phase from the data itself [19, (23–29)].”
BackgroundMethodParallel MR Image Reconstruction Using Augmented Lagrangian Methods
Ramani, S., & Fessler, J. A. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2093536 · Cited by 227
Jaermann, T., Crelier, G., Pruessmann, K. P., Golay, X., Netsch, T., van Muiswinkel, A. M. C., Mori, S., van Zijl, P. C. M., Valavanis, A., Kollias, S., et al. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10707 · Cited by 209 · cited 2×
“Single-shot EPI (ss-EPI) acquisition coupled with parallel imaging is currently the preferred method for DWI acquisition, primarily due to its immunity to bulk motion and its short acquisition time (9–11).”
MethodP‐LORAKS: Low‐rank modeling of local k‐space neighborhoods with parallel imaging data
Haldar, J. P., & Zhuo, J. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25717 · Cited by 198
Navigated Diffusion Imaging of Normal and Ischemic Human Brain
De Crespigny, A. J., Marks, M. P., Enzmann, D. R., & Moseley, M. E. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330518 · Cited by 180 · cited 1×
“Multiplying Equation [18] by sjðxÞ and Equation [19] by siðxÞ and subtracting we get the following: milðxÞsjðxÞ mjlðxÞsiðxÞ 1⁄4 08i; j: [20]”
Annihilating Filter-Based Low-Rank Hankel Matrix Approach for Image Inpainting
Jin, K. H., & Ye, J. C. (2015) · IEEE Transactions on Image Processing · doi:10.1109/tip.2015.2446943 · Cited by 177 · cited 1×
“This property was exploited to recover the signal from under-sampled measurements in (34,35,38,39,47).”
BackgroundSkare, S. T., Newbould, R. D., Clayton, D., Albers, G. W., Nagle, S. K., & Bammer, R. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21176 · Cited by 156 · cited 7×
“Multi-shot diffusion weighted imaging (MS-DWI) holds great potential for enabling high spatial resolution diffusion imaging (7).”
BackgroundMethodInfluentialHigh‐resolution human diffusion tensor imaging using 2‐D navigated multishot SENSE EPI at 7 T
Jeong, H., Gore, J. C., & Anderson, A. W. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24320 · Cited by 146 · cited 3×
“Methods to estimate the phase fall into two categories: (i) methods that rely on navigator scans [16, (20–22)] and (ii) methods that estimates phase from the data itself [19, (23–29)].”
BackgroundMethodOff-the-Grid Recovery of Piecewise Constant Images from Few Fourier Samples
Ongie, G., & Jacob, M. (2016) · SIAM Journal on Imaging Sciences · doi:10.1137/15m1042280 · Cited by 134
Self-citationHeidemann, R. M., Anwander, A., Feiweier, T., Knösche, T. R., & Turner, R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.081 · Cited by 131
Liu, C., Moseley, M. E., & Bammer, R. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20706 · Cited by 128
Acceleration of MR parameter mapping using annihilating filter‐based low rank hankel matrix (ALOHA)
Lee, D., Jin, K. H., Kim, E. Y., Park, S., & Ye, J. C. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26081 · Cited by 110 · cited 2×
“Recently this idea was also extended to calibration-less parallel imaging reconstruction using structured low-rank matrix completion (31,33,35,55).”
BackgroundMethodCompressive Sampling Using Annihilating Filter-Based Low-Rank Interpolation
Ye, J. C., Kim, J., Jin, K. H., & Lee, K. (2016) · IEEE Transactions on Information Theory · doi:10.1109/tit.2016.2629078 · Cited by 88
Kim, T. H., Setsompop, K., & Haldar, J. P. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26182 · Cited by 77 · cited 3×
“Theannihilating filter-based approach in this paper is also theoretically similar to the recent ALOHA-based approach introduced in (37) and the SENSE-LORAKS method introduced in (55,57).”
MethodInfluentialParallel reconstruction using null operations
Zhang, J., Liu, C., & Moseley, M. E. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22899 · Cited by 72
Lee, J., Jin, K. H., & Ye, J. C. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26077 · Cited by 68
Motion immune diffusion imaging using augmented MUSE for high‐resolution multi‐shot EPI
Guhaniyogi, S., Chu, M., Chang, H., Song, A. W., & Chen, N. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25624 · Cited by 49
Self‐navigated multishot echo‐planar pulse sequence for high‐resolution diffusion‐weighted imaging
Nunes, R. G., Jezzard, P., Behrens, T. E. J., & Clare, S. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20499 · Cited by 45 · cited 1×
“b~ m 1⁄4 min rankðH1ð b mÞÞ subject to b SH2ð b mÞ 1⁄4 0; and A b m 1⁄4 b y [24] The last term imposes the data consistency to the measured multi-channel multi-shot k-space data, b y, of dimension N1 N2 Nc Ns.”
Lundell, H., Alexander, D. C., & Dyrby, T. B. (2014) · NMR in Biomedicine · doi:10.1002/nbm.3137 · Cited by 44 · cited 1×
“The unconstrained minimization problems in Equations [7], [14] are converted to constrained forms using an auxiliary variable D to get the new cost C1: C1 1⁄4 jjAb m b y jj2‘2 þ ljjDjj such that Fð b mÞ 1⁄4 D [15]”
MethodChang, H., Guhaniyogi, S., & Chen, N. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25318 · Cited by 42
MULTICHANNEL ESTIMATION OF COIL SENSITIVITIES IN PARALLEL MRI
Morrison, R., Jacob, M., & Do, M. N. (2007) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2007.356802 · Cited by 30 · cited 1×
“This work exploits the recent advances in multi-channel MR image recovery, which utilizes the annihilation relations between the sensitivity weighted images or their Fourier samples (30–37).”
BackgroundSelf-citationCorrection of motional artifacts in diffusion‐weighted images using a reference phase map
Uluğ, A. M., Barker, P. B., & van Zijl, P. C. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340327 · Cited by 29 · cited 1×
“:3) c m jl ½ k (cid:4) (cid:5) b s i ½ k (cid:4) ¼ 0 8 i ; j : [21] Replacing the convolution operations in Equation [21] as multiplication using Toeplitz/Hankel matrices, we get H ð c m il Þ (cid:6) b s j ½ k (cid:4) (cid”
MethodBasser (2000) · doi:10.1002/1522-2594(200010)44:4<625::aid-mrm17>3.0.co;2-o · cited 3×
“…the l th shot ( m l ð x Þ ) will have a phase term (40) that will be different from the measured DWI from the i th shot ( m i ð x Þ ), leading us to write m l ð x Þ ¼ r ð x Þ f l ð x Þ ; 8 x : [1] and Here, we assume that the phase f ð x Þ is also a complex quantity such that j f ð x Þj ¼ 1 ; 8 x .”
Method
Cited by
Jin, K. H., Lee, D., & Ye, J. C. (2016) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2016.2601296 · Cited by 245
Metadata
- Authors
- Mani, M., Jacob, M., Kelley, D., & Magnotta, V.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2016-08-23
- Volume
- 78
- Issue
- 2
- Pages
- 494-507
- ISSN
- 0740-3194 (ISSN-L)
- OpenAlex
- W2513707163
- Cited by
- 162
- References
- 46
- FWCI
- 10.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.