The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
In vivo characterization of the liver fat 1H MR spectrum
Open accessAbstract
A theoretical triglyceride model was developed for in vivo human liver fat 1 H MRS characterization, using the number of double bonds (CHCH), number of methylene‐interrupted double bonds (CHCHCH 2CHCH) and average fatty acid chain length. Five 3 T, single‐voxel, stimulated echo acquisition mode spectra (STEAM) were acquired consecutively at progressively longer TEs in a fat–water emulsion phantom and in 121 human subjects with known or suspected nonalcoholic fatty liver disease. T2‐corrected peak areas were calculated. Phantom data were used to validate the model. Human data were used in the model to determine the complete liver fat spectrum. In the fat–water emulsion phantom, the spectrum predicted by the model (based on known fatty acid chain distribution) agreed closely with spectroscopic measurement. In human subjects, areas of CH 2 peaks at 2.1 and 1.3 ppm were linearly correlated (slope, 0.172; r = 0.991), as were the 0.9 ppm CH 3 and 1.3 ppm CH 2 peaks (slope, 0.125; r = 0.989). The 2.75 ppm CH 2 peak represented 0.6% of the total fat signal in high‐liver‐fat subjects. These values predict that 8.6% of the total fat signal overlies the water peak. The triglyceride model can characterize human liver fat spectra. This allows more accurate determination of liver fat fraction from MRI and MRS. Copyright © 2010 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Improved Method for Accurate and Efficient Quantification of MRS Data with Use of Prior Knowledge
Vanhamme, L., van den Boogaart, A., & Van Huffel, S. (1997) · Journal of Magnetic Resonance · doi:10.1006/jmre.1997.1244 · Cited by 1,627
Szczepaniak, L. S., Nurenberg, P., Leonard, D., Browning, J. D., Reingold, J. S., Grundy, S., Hobbs, H. H., & Dobbins, R. L. (2005) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00064.2004 · Cited by 1,562
Java-based graphical user interface for the MRUI quantitation package
Naressi, A., Couturier, C., Devos, J. M., Janssen, M., Mangeat, C., Beer, R. D., & Graveron-Demilly, D. (2001) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/bf02668096 · Cited by 1,003
ARAYA, J., RODRIGO, R., VIDELA, L. A., THIELEMANN, L., ORELLANA, M., PETTINELLI, P., & PONIACHIK, J. (2004) · Clinical Science · doi:10.1042/cs20030326 · Cited by 700
Yu, H., Shimakawa, A., McKenzie, C. A., Brodsky, E., Brittain, J. H., & Reeder, S. B. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21737 · Cited by 694
Measurement of intracellular triglyceride stores by H spectroscopy: validation in vivo
Szczepaniak, L. S., Babcock, E. E., Schick, F., Dobbins, R. L., Garg, A., Burns, D. K., McGarry, J. D., & Stein, D. T. (1999) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1999.276.5.e977 · Cited by 688
Relaxation effects in the quantification of fat using gradient echo imaging
Bydder, M., Yokoo, T., Hamilton, G., Middleton, M. S., Chavez, A. D., Schwimmer, J. B., Lavine, J. E., & Sirlin, C. B. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.08.012 · Cited by 394
Self-citationProton MR spectroscopy in quantitative in vivo determination of fat content in human liver steatosis
Longo, R., Pollesello, P., Ricci, C., Masutti, F., Kvam, B. J., Bercich, L., Croce, L. S., Grigolato, P., Paoletti, S., De Bernard, B., et al. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050311 · Cited by 387
Composition of adipose tissue and marrow fat in humans by 1H NMR at 7 Tesla
Ren, J., Dimitrov, I., Sherry, A. D., & Malloy, C. R. (2008) · Journal of Lipid Research · doi:10.1194/jlr.d800010-jlr200 · Cited by 386
Quantification of liver fat using magnetic resonance spectroscopy
Thomsen, C., Becker, U., Winkler, K., Christoffersen, P., Jensen, M., & Henriksen, O. (1994) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)92543-7 · Cited by 332
Yokoo, T., Bydder, M., Hamilton, G., Middleton, M. S., Gamst, A. C., Wolfson, T., Hassanein, T., Patton, H. M., Lavine, J. E., Schwimmer, J. B., et al. (2009) · Radiology · doi:10.1148/radiol.2511080666 · Cited by 303
Self-citation1H and13C NMR of virgin olive oil. An overview
Sacchi, R., Addeo, F., & Paolillo, L. (1997) · Magnetic Resonance in Chemistry · doi:10.1002/(sici)1097-458x(199712)35:13<s133::aid-omr213>3.0.co;2-k · Cited by 274
LONGO, R., RICC, C., MASUTTI, F., VIDIMARI, R., CROC??, L. S., BERCICH, L., TIRIBELLI, C., & PALMA, L. D. (1993) · Investigative Radiology · doi:10.1097/00004424-199304000-00006 · Cited by 273
Schwimmer, J. B., Middleton, M. S., Deutsch, R., & Lavine, J. E. (2005) · Alimentary Pharmacology & Therapeutics · doi:10.1111/j.1365-2036.2005.02420.x · Cited by 243
Self-citationQuerleux, B., Cornillon, C., Jolivet, O., & Bittoun, J. (2002) · Skin Research and Technology · doi:10.1034/j.1600-0846.2002.00331.x · Cited by 226
Role of Radiologic Modalities in the Management of Non-alcoholic Steatohepatitis
Charatcharoenwitthaya, P., & Lindor, K. D. (2007) · Clinics in Liver Disease · doi:10.1016/j.cld.2007.02.014 · Cited by 218
Effect of PRESS and STEAM sequences on magnetic resonance spectroscopic liver fat quantification
Hamilton, G., Middleton, M. S., Bydder, M., Yokoo, T., Schwimmer, J. B., Kono, Y., Patton, H. M., Lavine, J. E., & Sirlin, C. B. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21809 · Cited by 215
Self-citationKechagias, S., Ernersson, Å., Dahlqvist, O., Lundberg, P., Lindström, T., Nystrom, F. H., & for the Fast Food Study Group (2008) · Gut · doi:10.1136/gut.2007.131797 · Cited by 201
Johnson, N. A., Walton, D. W., Sachinwalla, T., Thompson, C. H., Smith, K., Ruell, P. A., Stannard, S. R., & George, J. (2008) · Hepatology · doi:10.1002/hep.22220 · Cited by 164
Field, C., Angel, A., & Clandinin, M. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/42.6.1206 · Cited by 162
Diagnosing Inborn Errors of Lipid Metabolism with Proton Nuclear Magnetic Resonance Spectroscopy
Oostendorp, M., Engelke, U. F. H., Willemsen, M. A., & Wevers, R. A. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2006.069112 · Cited by 105
Optimal phased-array combination for spectroscopy
Bydder, M., Hamilton, G., Yokoo, T., & Sirlin, C. B. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2008.01.050 · Cited by 92
Self-citationAssessment of in vivo 1H magnetic resonance spectroscopy in the liver: a review
Fischbach, F., & Bruhn, H. (2008) · Liver International · doi:10.1111/j.1478-3231.2007.01647.x · Cited by 73
Spatial localization in nuclear magnetic resonance spectroscopy
Keevil, S. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/16/r01 · Cited by 68
Response of metabolites with coupled spins to the STEAM sequence
Thompson, R. B., & Allen, P. S. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1128 · Cited by 64
Zancanaro, C., Nano, R., Marchioro, C., Sbarbati, A., Boicelli, A. C., & Osculati, F. (1994) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)39925-9 · Cited by 63
Guiu, B., Loffroy, R., Petit, J., Aho, S., Salem, D. B., Masson, D., Hillon, P., Cercueil, J., & Krause, D. (2009) · European Radiology · doi:10.1007/s00330-009-1330-9 · Cited by 62
In vivo detection and quantification of scalar coupled1H NMR resonances
de Graaf, R. A., & Rothman, D. L. (2000) · Concepts in Magnetic Resonance · doi:10.1002/1099-0534(2001)13:1 · Cited by 61
Investigating the wavelet coherence phase of the BOLD signal
Müller, K., Lohmann, G., Neumann, J., et al. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20064 · Cited by 46
Cobbold, J., Taylor-Robinson, S. D., & Cox, I. J. (2008) · Hepatology · doi:10.1002/hep.22453 · Cited by 7
Nimitphong, H., Phongkitkarun, S., Rattarasarn, C., Kongsooksai, A., Chanprasertyothin, S., Bunnag, P., & Puavilai, G. (2008) · Metabolism · doi:10.1016/j.metabol.2007.12.008 · Cited by 5
Cited by
Noninvasive assessment of liver disease in patients with nonalcoholic fatty liver disease
Castera, L., Friedrich-Rust, M., & Loomba, R. (2019) · Gastroenterology · doi:10.1053/j.gastro.2018.12.036 · Cited by 1,494
Timmers, S., Konings, E., Bilet, L., Houtkooper, R. H., van de Weijer, T., Goossens, G. H., Hoeks, J., van der Krieken, S., Ryu, D., Kersten, S., et al. (2011) · Cell Metabolism · doi:10.1016/j.cmet.2011.10.002 · Cited by 1,320
Noureddin, M., Lam, J., Peterson, M. R., Middleton, M., Hamilton, G., Le, T.-A., Bettencourt, R., Changchien, C., Brenner, D. A., Sirlin, C., et al. (2013) · Hepatology · doi:10.1002/hep.26455 · Cited by 550
Self-citationTang, A., Tan, J., Sun, M., Hamilton, G., Bydder, M., Wolfson, T., Gamst, A. C., Middleton, M., Brunt, E. M., Loomba, R., et al. (2013) · Radiology · doi:10.1148/radiol.12120896 · Cited by 528
Self-citationProton density fat‐fraction: A standardized mr‐based biomarker of tissue fat concentration
Reeder, S. B., Hu, H. H., & Sirlin, C. B. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23741 · Cited by 501
Self-citation
Metadata
- Authors
- Hamilton, G., Yokoo, T., Bydder, M., Cruite, I., Schroeder, M. E., Sirlin, C. B., & Middleton, M. S.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2010-12-12
- Volume
- 24
- Issue
- 7
- Pages
- 784-790
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2129011084
- Cited by
- 520
- References
- 31
- FWCI
- 17.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.