The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Tissue specific perfusion imaging using arterial spin labeling
Abstract
Quantitative magnetic resonance measurements of regional tissue perfusion can be obtained using magnetically labeled arterial water as a diffusable tracer. Continuous labeling is achieved in flowing spins using adiabatic inversion. The effects of continuous labeling of proximal arterial spins and T1 relaxation in distal tissue magnetization result in a steady‐state change in tissue magnetization which is tissue specific, i.e., it can be quantified in units of blood flow per gram of tissue per unit time. This magnetization is sampled using standard imaging sequences. The theoretical basis for this method, including the effects of macromolecular spin saturation, is reviewed. Recent results demonstrating the successful implementation of this technique in vitro and in vivo in rat brain, heart, and kidney, and in human brain and kidney are presented, as well as the use of a separate RF coil for arterial labeling to produce selective perfusion images in rat brain. This approach allows quantitative perfusion images to be obtained completely non‐invasively at the resolution of 1 H MRI, and is useful in the clinical and investigational evaluation of organ physiology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Detre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230106 · Cited by 1,571
Self-citationMagnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
Self-citationTHE DETERMINATION OF CEREBRAL BLOOD FLOW IN MAN BY THE USE OF NITROUS OXIDE IN LOW CONCENTRATIONS
Kety, S. S., & Schmidt, C. F. (1945) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1945.143.1.53 · Cited by 1,053
Magnetic Resonance Imaging of the Brain and Spine
HEALTH AND PUBLIC POLICY COMMITTEE* (1988) · Annals of Internal Medicine · doi:10.7326/0003-4819-108-3-474 · Cited by 725
Projection angiograms of blood labeled by adiabatic fast passage
Dixon, W. T., Du, L. N., Faul, D. D., Gado, M., & Rossnick, S. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030311 · Cited by 282
Perfusion imaging by nuclear magnetic resonance.
Rosen, B. R., Belliveau, J. W., & Chien, D. (1989) · PubMed · Cited by 273
Quantitative 1H magnetization transfer imaging in vivo
Eng, J., Ceckler, T. L., & Balaban, R. S. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170203 · Cited by 236
Nuclear magnetic cross-relaxation spectroscopy
Grad, J., & Bryant, R. G. (1990) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(90)90361-c · Cited by 197
Roberts, D. A., Detre, J. A., Bolinger, L., Insko, E. K., & Leigh, J. S. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.1.33 · Cited by 177
Self-citationCombination of Dynamic and Integral Methods for Generating Reproducible Functional CBF Images
Lammertsma, A. A., Cunningham, V. J., Deiber, M., Heather, J. D., Bloomfield, P. M., Nutt, J. G., Frackowiak, R. S. J., & Jones, T. (1990) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1990.121 · Cited by 146
Zhang, W., Williams, D. S., & Koretsky, A. P. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290323 · Cited by 139
Self-citationZhang, W., Williams, D. S., Detre, J. A., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250216 · Cited by 124
Self-citationWilliams, D. S., Grandis, D. J., Zhang, W., & Koretsky, A. P. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300314 · Cited by 96
Self-citationMeasurement of regional cerebral blood flow in cat brain using intracarotid 2H2O and 2H NMR imaging
Detre, J. A., Subramanian, V. H., Mitchell, M. D., Smith, D. S., Kobayashi, A., Zaman, A., & Leigh, J. S. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140223 · Cited by 65
Self-citationJones, S. C., Greenberg, J. H., & Reivich, M. (1982) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198202000-00020 · Cited by 62
Cited by
Alsop, D. C., Detre, J. A., Golay, X., Günther, M., Hendrikse, J., Hernandez‐Garcia, L., Lu, H., MacIntosh, B. J., Parkes, L. M., Smits, M., et al. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25197 · Cited by 2,206
Self-citationDiffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
MRI of the tumor microenvironment
Gillies, R. J., Raghunand, N., Karczmar, G. S., & Bhujwalla, Z. M. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10181 · Cited by 550
Real-time fMRI neurofeedback: Progress and challenges
Sulzer, J., Haller, S., Scharnowski, F., Weiskopf, N., Birbaumer, N., Blefari, M. L., Bruehl, A. B., Cohen, L. G., deCharms, R. C., Gassert, R., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.03.033 · Cited by 453
“ASL traces arterial blood as it flows into the brain (regional cerebral blood flow, rCBF) by “tagging” arterial blood magnetically and then measuring the response approximately one second later in the brain (Detre et al., 1994) and comparing it to a “non-tagged” control condition.”
Background
Metadata
- Authors
- Detre, J. A., Zhang, W., Roberts, D. A., Silva, A. C., Williams, D. S., Grandis, D. J., Koretsky, A. P., & Leigh, J. S.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 1994-03
- Volume
- 7
- Issue
- 1-2
- Pages
- 75-82
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2156057467
- Cited by
- 335
- References
- 17
- FWCI
- 6.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.