Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 338

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Reproducibility of dynamic contrast‐enhanced MRI in human muscle and tumours: comparison of quantitative and semi‐quantitative analysis

Open access
Galbraith, Susan M., Lodge, Martin A., Taylor, N. Jane, Rustin, Gordon J. S., Bentzen, Søren, Stirling, J. James, Padhani, Anwar R.·2002·NMR in Biomedicine

Abstract

The purpose of this study was to determine the reproducibility of dynamic contrast‐enhanced (DCE)‐MRI and compare quantitative kinetic parameters with semi‐quantitative methods, and whole region‐of‐interest (ROI) with pixel analysis. Twenty‐one patients with a range of tumour types underwent paired MRI examinations within a week, of which 16 pairs were evaluable. A proton density‐weighted image was obtained prior to a dynamic series of 30 T1‐weighted spoiled gradient echo images every 11.9 s with an intravenous bolus of gadopentetate dimeglumine given after the third baseline data point. Identical ROIs around the whole tumour and in skeletal muscle were drawn by the same observer on each pair of examinations and used for the reproducibility analysis. Semi‐quantitative parameters, gradient, enhancement and AUC (area under the curve) were derived from tissue enhancement curves. Quantitative parameters (Ktrans, kep, ve) were obtained by the application of the Tofts' model. Analysis was performed on data averaged across the whole ROI and on the median value from individual pixels within the ROI. No parameter showed a significant change between examinations. For all parameters except Ktrans, the variability was not dependent on the parameter value, so the absolute values for the size of changes needed for significance should be used for future reference rather than percentages. The size of change needed for significance in a group of 16 in tumours for Ktrans, kep and ve was −14 to +16%, ±0.20 ml/ml/min (15%) and ±1.9 ml/ml (6%), respectively (pixel analysis), and −16 to +19%, ±0.23 ml/ml/min (16%) and ±1.9 ml/ml (6%) (whole ROI analysis). For a single tumour, changes greater than −45 to +83%, ± 0.78 ml/ml/min (60%) and ± 7.6 ml/ml (24%), respectively, would be significant (pixel analysis). For gradient, enhancement and AUC the size of change needed for significance in tumours was ±0.24 (17%), ±0.05 (6%) and ±0.06 (8%), respectively for a group of 16 (pixel analysis), and ±0.96 (68%), ±0.20 (25%) and ±0.22 (32%) for individuals. In muscle, the size of change needed for significance in a group of 16 for Ktrans, kep and ve was −30 to +44%, ±0.81 ml/ml/min (61%) and ±1.7 ml/ml (13%). For gradient, enhancement and AUC it was ±0.09 (20%), ±0.02 (8%) and ±0.03 (12%). ve, enhancement and AUC are highly reproducible DCE‐MRI parameters. Ktrans, kep and gradient have greater variability, with larger changes in individuals required to be statistically significant, but are nevertheless sufficiently reproducible to detect changes greater than 14–17% in a cohort of 16 patients. Pixel analyses slightly improve reproducibility estimates and retain information about spatial heterogeneity. Reproducibility studies are recommended when treatment effects are being monitored. Copyright © 2002 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/nbm.731

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 338

Metadata

Authors
Galbraith, S. M., Lodge, M. A., Taylor, N. J., Rustin, G. J. S., Bentzen, S., Stirling, J. J., & Padhani, A. R.
Venue
NMR in Biomedicine
Publisher
Wiley
Published
2002-02-20
Volume
15
Issue
2
Pages
132-142
ISSN
  • 0952-3480 (ISSN-L)
  • 1099-1492
OpenAlex
W2050423483
Cited by
338
References
14
FWCI
11.90
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.