The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Diffusion tensor fiber tracking of human brain connectivity: aquisition methods, reliability analysis and biological results
Open accessAbstract
We present a description, biological results and a reliability analysis for the method of diffusion tensor tracking (DTT) of white matter fiber pathways. In DTT, diffusion‐tensor MRI (DT‐MRI) data are collected and processed to visualize the line trajectories of fiber bundles within white matter (WM) pathways of living humans. A detailed description of the data acquisition is given. Technical aspects and experimental results are illustrated for the geniculo‐calcarine tract with broad projections to visual cortex, occipital and parietal U‐fibers, and the temporo‐calcarine ventral pathway. To better understand sources of error and to optimize the method, accuracy and precision were analyzed by computer simulations. In the simulations, noisy DT‐MRI data were computed that would be obtained for a WM pathway having a helical trajectory passing through gray matter. The error vector between the real and ideal track was computed, and random errors accumulated with the square root of track length consistent with a random‐walk process. Random error was most dependent on signal‐to‐noise ratio, followed by number of averages, pathway anisotropy and voxel size, in decreasing order. Systematic error only occurred for a few conditions, and was most dependent on the stepping algorithm, anisotropy of the surrounding tissue, and non‐equal voxel dimensions. Both random and systematic errors were typically below the voxel dimension. Other effects such as track rebound and track recovery also depended on experimental conditions. The methods, biological results and error analysis herein may improve the understanding and optimization of DTT for use in various applications in neuroscience and medicine. Copyright © 2002 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Diffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Fox, P. T., & Raichle, M. E. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.4.1140 · Cited by 2,056
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Amygdalo‐cortical projections in the monkey ( Macaca fascicularis )
Amaral, D. G., & Price, J. L. (1984) · Journal of Comparative Neurology · doi:10.1002/cne.902300402 · Cited by 1,162 · cited 1×
“4(c)] and the occipital pole, as found in monkeys.(66) The results in Fig.”
Diffusion Tensor Imaging and Axonal Tracking in the Human Brainstem
Stieltjes, B., Kaufmann, W. E., van Zijl, P. C. M., Fredericksen, K., Pearlson, G. D., Solaiyappan, M., & Mori, S. (2001) · NeuroImage · doi:10.1006/nimg.2001.0861 · Cited by 492
Transient decrease in water diffusion observed in human occipital cortex during visual stimulation
Darquié, A., Poline, J.-B., Poupon, C., Saint-Jalmes, H., & Le Bihan, D. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.151125698 · Cited by 194
Cited by
White matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
Makris, N., Kennedy, D. N., McInerney, S., Sorensen, A. G., Wang, R., Caviness, V. S., & Pandya, D. N. (2005) · Cerebral Cortex · doi:10.1093/cercor/bhh186 · Cited by 1,146
Diffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Diffusion MRI fiber tractography of the brain
Jeurissen, B., Descoteaux, M., Mori, S., & Leemans, A. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3785 · Cited by 574
Parker, G. J. M., Haroon, H. A., & Wheeler‐Kingshott, C. A. M. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10350 · Cited by 527
Metadata
- Authors
- Lori, N. F., Akbudak, E., Shimony, J. S., Cull, T. S., Snyder, A. Z., Guillory, R. K., & Conturo, T. E.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2002-11
- Volume
- 15
- Issue
- 7-8
- Pages
- 494-515
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2060622177
- Cited by
- 164
- References
- 7
- FWCI
- 8.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diffusion tensor fiber tracking of human brain connectivity: aquisition methods, reliability analysis and biological results. https://app.cochat.ai/papers/10.1002/nbm.779
- The paper
- Lori, N. F., Akbudak, E., Shimony, J. S., Cull, T. S., Snyder, A. Z., Guillory, R. K., & Conturo, T. E. (2002). Diffusion tensor fiber tracking of human brain connectivity: aquisition methods, reliability analysis and biological results. NMR in Biomedicine. https://doi.org/10.1002/nbm.779
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.