The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Sample preparation and digestion for proteomic analyses using spin filters
Abstract
We describe the use of commercially available microcentrifugation devices (spin filters) for cleanup and digestion of protein samples for mass spectrometry analyses. The protein sample is added to the upper chamber of a spin filter with a ≥ 3000 molecular weight cutoff membrane and then washed prior to resuspension in ammonium bicarbonate. The protein is then reduced, alkylated, and digested with trypsin in the upper chamber and the peptides are recovered by centrifugation through the membrane. The method provides digestion efficiencies comparable to standard in‐solution digests, avoids lengthy dialysis steps, and allows rapid cleanup of samples containing salts, some detergents, and acidic or basic buffers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Peng, J., Elias, J. E., Thoreen, C. C., Licklider, L. J., & Gygi, S. P. (2003) · Journal of Proteome Research · doi:10.1021/pr025556v · Cited by 1,647
Rosenfeld, J., Capdevielle, J., Guillemot, J. C., & Ferrara, P. (1992) · Analytical Biochemistry · doi:10.1016/0003-2697(92)90061-b · Cited by 1,239
The Protein Protocols Handbook
(2009) · Springer Protocols Handbooks · doi:10.1007/978-1-59745-198-7 · Cited by 1,132
Toward a Human Blood Serum Proteome
Adkins, J. N., Varnum, S. M., Auberry, K. J., Moore, R. J., Angell, N. H., Smith, R. D., Springer, D. L., & Pounds, J. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200066-mcp200 · Cited by 793
Hellman, U., Wernstedt, C., Gonez, J., & Heldin, C. H. (1995) · Analytical Biochemistry · doi:10.1006/abio.1995.1070 · Cited by 753
Doucette, A. A., Craft, D., & Li, L. (2000) · Analytical Chemistry · doi:10.1021/ac000176j · Cited by 84
Jiang, Y., & Lee, C. S. (2001) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)00718-x · Cited by 59
Cited by
Single-pot, solid-phase-enhanced sample preparation for proteomics experiments
Hughes, C. S., Moggridge, S., Müller, T., Sorensen, P. H., Morin, G. B., & Krijgsveld, J. (2019) · Nature Protocols · doi:10.1038/s41596-018-0082-x · Cited by 1,941
Kulak, N. A., Pichler, G., Paron, I., Nagaraj, N., & Mann, M. (2014) · Nature Methods · doi:10.1038/nmeth.2834 · Cited by 1,719
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Structural basis of PROTAC cooperative recognition for selective protein degradation
Gadd, M. S., Testa, A., Lucas, X., Chan, K.-H., Chen, W., Lamont, D. J., Zengerle, M., & Ciulli, A. (2017) · Nature Chemical Biology · doi:10.1038/nchembio.2329 · Cited by 1,242
Artemisinins Target GABAA Receptor Signaling and Impair α Cell Identity
Li, J., Casteels, T., Frogne, T., Ingvorsen, C., Honoré, C., Courtney, M., Huber, K. V. M., Schmitner, N., Kimmel, R. A., Romanov, R. A., et al. (2017) · Cell · doi:10.1016/j.cell.2016.11.010 · Cited by 376
S-Trap, an Ultrafast Sample-Preparation Approach for Shotgun Proteomics
HaileMariam, M., Eguez, R. V., Singh, H., Bekele, S., Ameni, G., Pieper, R., & Yu, Y. (2018) · Journal of Proteome Research · doi:10.1021/acs.jproteome.8b00505 · Cited by 344
Erde, J., Loo, R. R. O., & Loo, J. A. (2014) · Journal of Proteome Research · doi:10.1021/pr4010019 · Cited by 331
Label-free quantification in ion mobility–enhanced data-independent acquisition proteomics
Distler, U., Kuharev, J., Navarro, P., & Tenzer, S. (2016) · Nature Protocols · doi:10.1038/nprot.2016.042 · Cited by 329
Sielaff, M., Kuharev, J., Bohn, T., Hahlbrock, J., Bopp, T., Tenzer, S., & Distler, U. (2017) · Journal of Proteome Research · doi:10.1021/acs.jproteome.7b00433 · Cited by 317
Recent advances in mass spectrometry based clinical proteomics: applications to cancer research
Macklin, A., Khan, S., & Kislinger, T. (2020) · Clinical Proteomics · doi:10.1186/s12014-020-09283-w · Cited by 317
Wiśniewski, J. R., & Mann, M. (2012) · Analytical Chemistry · doi:10.1021/ac300006b · Cited by 299
Ludwig, A., De Miroschedji, K., Doeppner, T. R., Börger, V., Ruesing, J., Rebmann, V., Durst, S., Jansen, S., Bremer, M., Behrmann, E., et al. (2018) · Journal of Extracellular Vesicles · doi:10.1080/20013078.2018.1528109 · Cited by 291
Feist, P., & Hummon, A. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16023537 · Cited by 288
Extending the Compatibility of the SP3 Paramagnetic Bead Processing Approach for Proteomics
Moggridge, S., Sorensen, P. H., Morin, G. B., & Hughes, C. S. (2018) · Journal of Proteome Research · doi:10.1021/acs.jproteome.7b00913 · Cited by 286
Methods for samples preparation in proteomic research
Bodzon-Kulakowska, A., Bierczynska-Krzysik, A., Dylag, T., Drabik, A., Suder, P., Noga, M., Jarzebinska, J., & Silberring, J. (2007) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.10.040 · Cited by 254
León, I. R., Schwämmle, V., Jensen, O. N., & Sprenger, R. R. (2013) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m112.025585 · Cited by 257
Spontaneous DNA damage to the nuclear genome promotes senescence, redox imbalance and aging
Robinson, A. R., Yousefzadeh, M. J., Rozgaja, T. A., Wang, J., Li, X., Tilstra, J. S., Feldman, C. H., Gregg, S. Q., Johnson, C. H., Skoda, E. M., et al. (2018) · Redox Biology · doi:10.1016/j.redox.2018.04.007 · Cited by 155
“Equal protein amounts were dialyzed, alkylated, and digested using the FASP methodology [43,44].”
MethodThe Revolution and Evolution of Shotgun Proteomics for Large-Scale Proteome Analysis
Yates, J. R. (2013) · Journal of the American Chemical Society · doi:10.1021/ja3094313 · Cited by 131
Liang, Y., Piao, C., Beuschel, C. B., Toppe, D., Kollipara, L., Bogdanow, B., Maglione, M., Lützkendorf, J., See, J. C. K., Huang, S., et al. (2021) · Cell Reports · doi:10.1016/j.celrep.2021.108941 · Cited by 130
New Mass-Spectrometry-Compatible Degradable Surfactant for Tissue Proteomics
Chang, Y.-H., Gregorich, Z. R., Chen, A. J., Hwang, L., Guner, H., Yu, D., Zhang, J., & Ge, Y. (2015) · Journal of Proteome Research · doi:10.1021/pr5012679 · Cited by 80
The benefits (and misfortunes) of SDS in top-down proteomics
Kachuk, C., & Doucette, A. A. (2018) · Journal of Proteomics · doi:10.1016/j.jprot.2017.03.002 · Cited by 39
Proteogenomics reveals sex-biased aging genes and coordinated splicing in cardiac aging
Han, Y., Wennersten, S. A., Wright, J. M., Ludwig, R. W., Lau, E., & Lam, M. P. Y. (2022) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00244.2022 · Cited by 31
Boyd, J. M., Ryan Kaler, K., Esquilín-Lebrón, K., Pall, A., Campbell, C. J., Foley, M. E., Rios-Delgado, G., Mustor, E. M., Stephens, T. G., Bovermann, H., et al. (2024) · mBio · doi:10.1128/mbio.02310-24 · Cited by 14
Boyd, J. M., Esquilín-Lebrón, K., Campbell, C. J., Kaler, K. R., Norambuena, J., Foley, M. E., Stephens, T. G., Rios, G., Mereddy, G., Zheng, V., et al. (2023) · doi:10.1101/2023.10.03.560778 · Cited by 4
Metadata
- Authors
- Manza, L. L., Stamer, S. L., Ham, A. L., Codreanu, S. G., & Liebler, D. C.
- Venue
- PROTEOMICS
- Publisher
- Wiley
- Published
- 2005-05
- Volume
- 5
- Issue
- 7
- Pages
- 1742-1745
- ISSN
- 1615-9853 (ISSN-L)
- 1615-9861
- OpenAlex
- W1997958695
- Cited by
- 382
- References
- 8
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.