Synthesis and characterization of thermoresponsive poly(ethylene glycol)‐based hydrogels and their magnetic nanocomposites
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Temperature‐responsive hydrogels are one of the most widely studied types of stimuli‐responsive hydrogel systems. Their ability to transition between their swollen and collapsed states makes them attractive for controlled drug delivery, microfluidic devices, and biosensor applications. Recent work has shown that poly(ethylene glycol) (PEG) methacrylate polymers are temperature‐responsive and exhibit a wide range of lower critical solution temperatures based on the length of ethylene glycol units in the macromer chain. The addition of iron oxide nanoparticles into the hydrogel matrix can provide the ability to remotely heat the gels upon exposure to an alternating magnetic field (AMF). In this work, diethylene glycol (n = 2) methyl ether methacrylate and PEG (n = 4.5) methyl ether methacrylate copolymers were polymerized into hydrogels with 5 mol % PEG 600 (n = 13.6) dimethacrylate as the crosslinker along with 5 wt % iron oxide nanoparticles. Volumetric swelling studies were completed from 22 to 80 °C and confirmed the temperature‐responsive nature of the hydrogel systems. The ability of the gels to collapse in response to rapid temperature changes when exposed to an AMF was demonstrated showing their potential use in biomedical applications such as controlled drug delivery and hyperthermia therapy. © 2010 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 48: 3229–3235, 2010
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogels in pharmaceutical formulations
Peppas, N. (2000) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/s0939-6411(00)00090-4 · Cited by 4,011
Cited by
Magnetic fluid hyperthermia: focus on superparamagnetic iron oxide nanoparticles
Laurent, S., Dutz, S., Häfeli, U. O., & Mahmoudi, M. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2011.04.003 · Cited by 1,326
Stimulus-responsive hydrogels: theory, modern advances, and applications
Koetting, M. C., Peters, J. T., Steichen, S. D., & Peppas, N. A. (2015) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2015.04.001 · Cited by 1,191
Thermoresponsive Polymers for Biomedical Applications
Ward, M. A., & Georgiou, T. K. (2011) · Polymers · doi:10.3390/polym3031215 · Cited by 1,158
Studies on thermoresponsive polymers: Phase behaviour, drug delivery and biomedical applications
Gandhi, A., Paul, A., Sen, S. O., & Sen, K. K. (2015) · Asian Journal of Pharmaceutical Sciences · doi:10.1016/j.ajps.2014.08.010 · Cited by 506
“for possible drug delivery applications [62].”
Thermo‐Switchable Materials Prepared Using the OEGMA‐Platform
Lutz, J. (2011) · Advanced Materials · doi:10.1002/adma.201100597 · Cited by 411
Hydrogel Dressings for Advanced Wound Management
Francesko, A., Petkova, P., & Tzanov, T. (2019) · Current Medicinal Chemistry · doi:10.2174/0929867324666170920161246 · Cited by 269
Hydrogels in healthcare: From static to dynamic material microenvironments
Kirschner, C. M., & Anseth, K. S. (2013) · Acta Materialia · doi:10.1016/j.actamat.2012.10.037 · Cited by 255
A Review of Injectable Polymeric Hydrogel Systems for Application in Bone Tissue Engineering
Kondiah, P., Choonara, Y., Kondiah, P., Marimuthu, T., Kumar, P., Du Toit, L., & Pillay, V. (2016) · Molecules · doi:10.3390/molecules21111580 · Cited by 219
“field, leading to deswelling of the hydrogel [33].”
BackgroundNon-linear PEG-based thermoresponsive polymer systems
Badi, N. (2017) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2016.12.006 · Cited by 168
Tang, S., Floy, M., Bhandari, R., Sunkara, M., Morris, A. J., Dziubla, T. D., & Hilt, J. Z. (2017) · ACS Omega · doi:10.1021/acsomega.7b01247 · Cited by 33
Self-citationRivera, K. O., Cuylear, D. L., Duke, V. R., O’Hara, K. M., Zhong, J. X., Elghazali, N. A., Finbloom, J. A., Kharbikar, B. N., Kryger, A. N., Miclau, T., et al. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1190371 · Cited by 22
“Where Mn is the number average molecular weight of the polymer, ] is the specific volume of the dry polymer, V1 is the molar volume of the solvent, χ is the Flory polymer solvent interaction parameter, ]2,s is the polymer volume fraction in the swollen state (defined as 1 QV) (Meenach et al., 2010), and ]2,r is the po…”
Background
Metadata
- Authors
- Meenach, S. A., Anderson, K. W., & Hilt, J. Z.
- Venue
- Journal of Polymer Science Part A: Polymer Chemistry
- Publisher
- Wiley
- Published
- 2010-06-25
- Volume
- 48
- Issue
- 15
- Pages
- 3229-3235
- ISSN
- 0887-624X (ISSN-L)
- 1099-0518
- OpenAlex
- W2072357913
- Cited by
- 57
- References
- 1
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.