The DOI matches its Crossref record.
Ionization enhancement in atmospheric pressure chemical ionization and suppression in electrospray ionization between target drugs and stable‐isotope‐labeled internal standards in quantitative liquid chromatography/tandem mass spectrometry
Abstract
The phenomena of ionization suppression in electrospray ionization (ESI) and enhancement in atmospheric pressure chemical ionization (APCI) were investigated in selected‐ion monitoring and selected‐reaction monitoring modes for nine drugs and their corresponding stable‐isotope‐labeled internal standards (IS). The results showed that all investigated target drugs and their co‐eluting isotope‐labeled IS suppress each other's ionization responses in ESI. The factors affecting the extent of suppression in ESI were investigated, including structures and concentrations of drugs, matrix effects, and flow rate. In contrast to the ESI results, APCI caused seven of the nine investigated target drugs and their co‐eluting isotope‐labeled IS to enhance each other's ionization responses. The mutual ionization suppression or enhancement between drugs and their isotope‐labeled IS could possibly influence assay sensitivity, reproducibility, accuracy and linearity in quantitative liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS). However, calibration curves were linear if an appropriate IS concentration was selected for a desired calibration range to keep the response factors constant. Copyright © 2003 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Peters, F. T., Drummer, O. H., & Musshoff, F. (2007) · Forensic Science International · doi:10.1016/j.forsciint.2006.05.021 · Cited by 1,343
(2013) · Journal of Analytical Toxicology · doi:10.1093/jat/bkt054 · Cited by 873
An overview of matrix effects in liquid chromatography–mass spectrometry
Trufelli, H., Palma, P., Famiglini, G., & Cappiello, A. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20298 · Cited by 811
Signal suppression/enhancement in high-performance liquid chromatography tandem mass spectrometry
Gosetti, F., Mazzucco, E., Zampieri, D., & Gennaro, M. C. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.060 · Cited by 680
Chemical derivatization and mass spectral libraries in metabolic profiling by GC/MS and LC/MS/MS
Halket, J. M., Waterman, D., Przyborowska, A. M., Patel, R. K. P., Fraser, P. D., & Bramley, P. M. (2005) · Journal of Experimental Botany · doi:10.1093/jxb/eri069 · Cited by 662
Recent advances in high-throughput quantitative bioanalysis by LC–MS/MS
Xu, R. N., Fan, L., Rieser, M. J., & El-Shourbagy, T. A. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.02.006 · Cited by 530
Matrix effects in quantitative pesticide analysis using liquid chromatography–mass spectrometry
Niessen, W. M. A., Manini, P., & Andreoli, R. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20097 · Cited by 435
Protein Complexes in the Gas Phase: Technology for Structural Genomics and Proteomics
Benesch, J. L. P., Ruotolo, B. T., Simmons, D. A., & Robinson, C. V. (2007) · Chemical Reviews · doi:10.1021/cr068289b · Cited by 408
Matrix effects in pesticide multi-residue analysis by liquid chromatography–mass spectrometry
Kruve, A., Künnapas, A., Herodes, K., & Leito, I. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.01.077 · Cited by 322
Cortese, M., Gigliobianco, M. R., Magnoni, F., Censi, R., & Di Martino, P. (2020) · Molecules · doi:10.3390/molecules25133047 · Cited by 280
Mohapatra, D. P., Brar, S. K., Tyagi, R. D., Picard, P., & Surampalli, R. Y. (2014) · Science of The Total Environment · doi:10.1016/j.scitotenv.2013.09.034 · Cited by 272
Wick, A., Fink, G., & Ternes, T. A. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.079 · Cited by 262
Current role of liquid chromatography–mass spectrometry in clinical and forensic toxicology
Maurer, H. H. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1248-5 · Cited by 257
LITTLE, J., WEMPE, M., & BUCHANAN, C. (2006) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.02.011 · Cited by 256
Overcoming Matrix Effects in Liquid Chromatography−Mass Spectrometry
Cappiello, A., Famiglini, G., Palma, P., Pierini, E., Termopoli, V., & Trufelli, H. (2008) · Analytical Chemistry · doi:10.1021/ac8018312 · Cited by 253
Barri, T., Holmer-Jensen, J., Hermansen, K., & Dragsted, L. O. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.12.065 · Cited by 57
Metadata
- Authors
- Liang, H. R., Foltz, R. L., Meng, M., & Bennett, P.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2003-11-20
- Volume
- 17
- Issue
- 24
- Pages
- 2815-2821
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W1977706673
- Cited by
- 247
- References
- 0
- FWCI
- 5.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.