The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
A study of ion suppression effects in electrospray ionization from mobile phase additives and solid‐phase extracts
Abstract
Since the wide adoption of liquid chromatography/tandem mass spectrometry (LC/MS/MS), the ion suppression/enhancement phenomenon is the latest barrier to high‐throughput analysis. This consequence of a nonoptimized analytical method can lead to adverse effects during quantitation (i.e. poor accuracy and precision). Previous papers have reported that ion suppression is a direct result of endogenous material present in biological samples. However, in the case of a solid‐phase liquid chromatography/tandem mass spectrometry (SPE/LC/MS/MS) system, the measured result is the combination of several operating conditions and parameters. Little has been done to effectively monitor and/or choose optimized conditions for the complete sequence of extraction, clean up, separation and analysis. This paper describes a simple setup for quantification of ion suppression/enhancement. Several mobile phase additives, ion‐pairing agents and SPE extracts were measured and compared against a standard reference. The results demonstrated that a clean up of plasma extracts based on ion exchange leads to minimal ion suppression/enhancement for the compounds that were investigated. Copyright © 2003 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M. (2003) · Analytical Chemistry · doi:10.1021/ac020361s · Cited by 5,335
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
Practical implications of some recent studies in electrospray ionization fundamentals
Cech, N. B., & Enke, C. G. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10008 · Cited by 1,435
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Mechanistic investigation of ionization suppression in electrospray ionization
King, R., Bonfiglio, R., Fernandez-Metzler, C., Miller-Stein, C., & Olah, T. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00163-x · Cited by 1,086
Mei, H., Hsieh, Y., Nardo, C., Xu, X., Wang, S., Ng, K., & Korfmacher, W. A. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.876 · Cited by 350
Protonation in electrospray mass spectrometry: Wrong-way-round or right-way-round?
Zhou, S., & Cook, K. D. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00174-4 · Cited by 140
Avery, M. J. (2002) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.895 · Cited by 115
van Hout, M. W. J., Niederländer, H. A. G., de Zeeuw, R. A., & de Jong, G. J. (2002) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.908 · Cited by 70
Cited by
Peters, F. T., Drummer, O. H., & Musshoff, F. (2007) · Forensic Science International · doi:10.1016/j.forsciint.2006.05.021 · Cited by 1,343
Taylor, P. J. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.11.007 · Cited by 1,248
Farré, M. L., Pérez, S., Kantiani, L., & Barceló, D. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.09.010 · Cited by 1,009
An overview of matrix effects in liquid chromatography–mass spectrometry
Trufelli, H., Palma, P., Famiglini, G., & Cappiello, A. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20298 · Cited by 811
Systematic and comprehensive strategy for reducing matrix effects in LC/MS/MS analyses
Chambers, E., Wagrowski-Diehl, D. M., Lu, Z., & Mazzeo, J. R. (2007) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.12.030 · Cited by 776
Self-citationDefinitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
Signal suppression/enhancement in high-performance liquid chromatography tandem mass spectrometry
Gosetti, F., Mazzucco, E., Zampieri, D., & Gennaro, M. C. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.060 · Cited by 680
Chemical derivatization and mass spectral libraries in metabolic profiling by GC/MS and LC/MS/MS
Halket, J. M., Waterman, D., Przyborowska, A. M., Patel, R. K. P., Fraser, P. D., & Bramley, P. M. (2005) · Journal of Experimental Botany · doi:10.1093/jxb/eri069 · Cited by 662
Recent advances in high-throughput quantitative bioanalysis by LC–MS/MS
Xu, R. N., Fan, L., Rieser, M. J., & El-Shourbagy, T. A. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.02.006 · Cited by 530
(CONTAM), E. P. O. C. I. T. F. C., Knutsen, H. K., Alexander, J., Barregård, L., Bignami, M., Brüschweiler, B., Ceccatelli, S., Cottrill, B., Dinovi, M., Edler, L., et al. (2018) · EFSA Journal · doi:10.2903/j.efsa.2018.5194 · Cited by 515
Effect of eluent on the ionization process in liquid chromatography–mass spectrometry
Kostiainen, R., & Kauppila, T. J. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.08.095 · Cited by 402
Does a stable isotopically labeled internal standard always correct analyte response?
Wang, S., Cyronak, M., & Yang, E. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2006.08.010 · Cited by 401
Metabolomics technologies and metabolite identification
Moco, S., Vervoort, J., Moco, S., Bino, R. J., De Vos, R. C. H., & Bino, R. (2007) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2007.08.003 · Cited by 390
Kuehnbaum, N. L., & Britz-McKibbin, P. (2013) · Chemical Reviews · doi:10.1021/cr300484s · Cited by 354
Hummel, D., Löffler, D., Fink, G., & Ternes, T. A. (2006) · Environmental Science & Technology · doi:10.1021/es061740w · Cited by 299
Current role of liquid chromatography–mass spectrometry in clinical and forensic toxicology
Maurer, H. H. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1248-5 · Cited by 257
Mullin, L., Katz, D. R., Riddell, N., Plumb, R., Burgess, J. A., Yeung, L. W. Y., & Jogsten, I. E. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.05.015 · Cited by 91
Zhang, D., Rios, D. R., Tam, V. H., & Chow, D. S.-L. (2014) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2014.07.001 · Cited by 29
Metadata
- Authors
- Mallet, C. R., Lu, Z., & Mazzeo, J. R.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2003-12-04
- Volume
- 18
- Issue
- 1
- Pages
- 49-58
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2144957010
- Cited by
- 441
- References
- 11
- FWCI
- 9.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.