Improved imaging resolution in desorption electrospray ionization mass spectrometry
The DOI matches its Crossref record.
Abstract
The imaging resolution of desorption electrospray ionization mass spectrometry (DESI‐MS) was investigated using printed patterns on paper and thin‐layer chromatography (TLC) plate surfaces. Resolution approaching 40 µm was achieved with a typical DESI‐MS setup, which is approximately 5 times better than the best resolution reported previously. This improvement was accomplished with careful control of operational parameters (particularly spray tip‐to‐surface distance, solvent flow rate, and spacing of lane scans). In addition, an appropriately strong analyte/surface interaction and uniform surface texture on the size scale no larger than the desired imaging resolution were required to achieve this resolution. Overall, conditions providing the smallest possible effective desorption/ionization area in the DESI impact plume region and minimizing the analyte redistribution on the surface during analysis led to improved DESI‐MS imaging resolution. Published in 2008 by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mass Spectrometric Imaging for Biomedical Tissue Analysis
Chughtai, K., & Heeren, R. M. A. (2010) · Chemical Reviews · doi:10.1021/cr100012c · Cited by 652
Mass spectrometry imaging under ambient conditions
Wu, C., Dill, A. L., Eberlin, L. S., Cooks, R. G., & Ifa, D. R. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21360 · Cited by 488
Mass Spectrometry: Recent Advances in Direct Open Air Surface Sampling/Ionization
Monge, M. E., Harris, G. A., Dwivedi, P., & Fernández, F. M. (2013) · Chemical Reviews · doi:10.1021/cr300309q · Cited by 476
Ifa, D. R., Wu, C., Ouyang, Z., & Cooks, R. G. (2010) · The Analyst · doi:10.1039/b925257f · Cited by 384
Weston, D. J. (2010) · The Analyst · doi:10.1039/b925579f · Cited by 357
Imaging mass spectrometry in microbiology
Watrous, J. D., & Dorrestein, P. C. (2011) · Nature Reviews Microbiology · doi:10.1038/nrmicro2634 · Cited by 338
Tissue Imaging Using Nanospray Desorption Electrospray Ionization Mass Spectrometry
Laskin, J., Heath, B. S., Roach, P. J., Cazares, L., & Semmes, O. J. (2012) · Analytical Chemistry · doi:10.1021/ac2021322 · Cited by 338
Mass spectrometry imaging for drug distribution studies
Prideaux, B., & Stoeckli, M. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.07.028 · Cited by 279
Eberlin, L. S., Ferreira, C. R., Dill, A. L., Ifa, D. R., & Cooks, R. G. (2011) · Biochimica et Biophysica Acta (BBA) - Molecular and Cell Biology of Lipids · doi:10.1016/j.bbalip.2011.05.006 · Cited by 257
Körber, A., Anthony, I. G. M., & Heeren, R. M. A. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.4c05249 · Cited by 88
Metadata
- Authors
- Kertesz, V., & Van Berkel, G. J.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2008-07-29
- Volume
- 22
- Issue
- 17
- Pages
- 2639-2644
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2051113542
- Cited by
- 149
- References
- 0
- FWCI
- 7.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.