CoChat

Development of a validated liquid chromatography/tandem mass spectrometry method for the distinction of thyronine and thyronamine constitutional isomers and for the identification of new deiodinase substrates

Piehl, Susanne, Heberer, Thomas, Balizs, Gabor, Scanlan, Thomas S., Köhrle, Josef · 2008 · Rapid Communications in Mass Spectrometry
Cited by 58

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Thyronines (THs) and thyronamines (TAMs) are two groups of endogenous iodine‐containing signaling molecules whose representatives differ from each other only regarding the number and/or the position of the iodine atoms. Both groups of compounds are substrates of three deiodinase isozymes, which catalyze the sequential reductive removal of iodine from the respective precursor molecule. In this study, a novel analytical method applying liquid chromatography/tandem mass spectrometry (LC‐MS/MS) was developed. This method permitted the unequivocal, simultaneous identification and quantification of all THs and TAMs in the same biological sample. Furthermore, a liquid‐liquid extraction procedure permitting the concurrent isolation of all THs and TAMs from biological matrices, namely deiodinase (Dio) reaction mixtures, was established. Method validation experiments with extracted TH and TAM analytes demonstrated that the method was selective, devoid of matrix effects, sensitive, linear over a wide range of analyte concentrations and robust in terms of reproducible recoveries, process efficiencies as well as intra‐assay and inter‐assay stability parameters. The method was applied to study the deiodination reactions of iodinated THs catalyzed by the three deiodinase isozymes. With the HPLC protocol developed herein, sufficient chromatographic separation of all constitutional TH and TAM isomers was achieved. Accordingly, the position of each iodine atom removed from a TH substrate in a Dio‐catalyzed reaction was backtracked unequivocally. While several established deiodination reactions were verified, two as yet unknown reactions, namely the phenolic ring deiodination of 3′,5′‐diiodothyronine (3′,5′‐T 2 ) by Dio2 and the tyrosyl ring deiodination of 3‐monoiodothyronine (3‐T 1 ) by Dio3, were newly identified. Copyright © 2008 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.3732

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Piehl, S., Heberer, T., Balizs, G., Scanlan, T. S., & Köhrle, J.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2008-09-29
Volume
22
Issue
20
Pages
3286-3296
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2162722072
Cited by
58
References
4
FWCI
3.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.