The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Enhancements in travelling wave ion mobility resolution
Abstract
The use of ion mobility separation to determine the collision cross‐section of a gas‐phase ion can provide valuable structural information. The introduction of travelling‐wave ion mobility within a quadrupole/time‐of‐flight mass spectrometer has afforded routine collision cross‐section measurements to be performed on a range of ionic species differing in gas‐phase size/structure and molecular weight at physiologically relevant concentrations. Herein we discuss the technical advances in the second‐generation travelling‐wave ion mobility separator, which result in up to a four‐fold increase in mobility resolution. This improvement is demonstrated using two reverse peptides (mw 490 Da), small ruthenium‐containing anticancer drugs (mw 427 Da), a cisplatin‐modified protein (mw 8776 Da) and the noncovalent tetradecameric chaperone complex GroEL (mw 802 kDa). What is also shown are that the collision cross‐sections determined using the second‐generation mobility separator correlate well with the previous generation and theoretically derived values. Copyright © 2011 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New trends for metal complexes with anticancer activity
Bruijnincx, P. C., & Sadler, P. J. (2008) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2007.11.013 · Cited by 1,306
Ion mobility–mass spectrometry
Kanu, A. B., Dwivedi, P., Tam, M., Matz, L., & Hill, H. H. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1383 · Cited by 1,154
Ion mobility–mass spectrometry analysis of large protein complexes
Ruotolo, B. T., Benesch, J. L. P., Sandercock, A. M., Hyung, S.-J., & Robinson, C. V. (2008) · Nature Protocols · doi:10.1038/nprot.2008.78 · Cited by 1,092
Structural Information from Ion Mobility Measurements: Effects of the Long-Range Potential
Mesleh, M. F., Hunter, J. M., Shvartsburg, A. A., Schatz, G. C., & Jarrold, M. F. (1996) · The Journal of Physical Chemistry · doi:10.1021/jp961623v · Cited by 1,043
Pringle, S. D., Giles, K., Wildgoose, J. L., Williams, J. P., Slade, S. E., Thalassinos, K., Bateman, R. H., Bowers, M. T., & Scrivens, J. H. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.07.021 · Cited by 808
Self-citationApplications of a travelling wave‐based radio‐frequency‐only stacked ring ion guide
Giles, K., Pringle, S. D., Worthington, K. R., Little, D., Wildgoose, J. L., & Bateman, R. H. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1641 · Cited by 727
Self-citationEvidence for Macromolecular Protein Rings in the Absence of Bulk Water
Ruotolo, B. T., Giles, K., Campuzano, I., Sandercock, A. M., Bateman, R. H., & Robinson, C. V. (2005) · Science · doi:10.1126/science.1120177 · Cited by 596
Self-citationFundamentals of Traveling Wave Ion Mobility Spectrometry
Shvartsburg, A. A., & Smith, R. D. (2008) · Analytical Chemistry · doi:10.1021/ac8016295 · Cited by 534
State-Selected and State-to-State Ion−Molecule Reaction Dynamics
Ng, C.-Y. (2002) · The Journal of Physical Chemistry A · doi:10.1021/jp020055i · Cited by 429
Protein Complexes in the Gas Phase: Technology for Structural Genomics and Proteomics
Benesch, J. L. P., Ruotolo, B. T., Simmons, D. A., & Robinson, C. V. (2007) · Chemical Reviews · doi:10.1021/cr068289b · Cited by 408
Smith, D. P., Knapman, T. W., Campuzano, I., Malham, R. W., Berryman, J. T., Radford, S. E., & Ashcroft, A. E. (2009) · European Journal of Mass Spectrometry · doi:10.1255/ejms.947 · Cited by 334
Self-citationThalassinos, K., Grabenauer, M., Slade, S. E., Hilton, G. R., Bowers, M. T., & Scrivens, J. H. (2009) · Analytical Chemistry · doi:10.1021/ac801916h · Cited by 240
Ruotolo, B. T., Hyung, S., Robinson, P. M., Giles, K., Bateman, R. H., & Robinson, C. V. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200702161 · Cited by 229
Self-citationWu, C., Siems, W. F., Klasmeier, J., & Hill, H. H. (2000) · Analytical Chemistry · doi:10.1021/ac990601c · Cited by 207
Scarff, C. A., Thalassinos, K., Hilton, G. R., & Scrivens, J. H. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3737 · Cited by 178
AVERAGE CROSS-SECTIONAL AREAS OF MOLECULES BY GASEOUS DIFFUSION METHODS
Mack, E. (1925) · Journal of the American Chemical Society · doi:10.1021/ja01687a007 · Cited by 166
Evidence for Many Resolvable Structures within Conformation Types of Electrosprayed Ubiquitin Ions
Koeniger, S. L., Merenbloom, S. I., & Clemmer, D. E. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp056165h · Cited by 165
Chaperonin Complexes Monitored by Ion Mobility Mass Spectrometry
van Duijn, E., Barendregt, A., Synowsky, S. A., Versluis, C., & Heck, A. J. R. (2009) · Journal of the American Chemical Society · doi:10.1021/ja8055134 · Cited by 152
Bagal, D., Zhang, H., & Schnier, P. D. (2008) · Analytical Chemistry · doi:10.1021/ac7020163 · Cited by 113
Characterising electrosprayed biomolecules using tandem-MS—the noncovalent GroEL chaperonin assembly
Sobott, F., & Robinson, C. V. (2004) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.05.010 · Cited by 112
Bugarcic, T., Nováková, O., Zerzánková, L., Vrána, O., Kašpárková, J., Habtemariam, A., Parsons, S., Sadler, P. J., & Brabec, V. (2008) · Journal of Medicinal Chemistry · doi:10.1021/jm8003043 · Cited by 106
Bagal, D., Valliere‐Douglass, J. F., Balland, A., & Schnier, P. D. (2010) · Analytical Chemistry · doi:10.1021/ac1013139 · Cited by 102
Ion mobility mass spectrometry of proteins in a modified commercial mass spectrometer
Thalassinos, K., Slade, S. E., Jennings, K. R., Scrivens, J. H., Giles, K., Wildgoose, J. L., Hoyes, J. B., Bateman, R. H., & Bowers, M. T. (2004) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.05.008 · Cited by 93
Self-citationTransfer of Structural Elements from Compact to Extended States in Unsolvated Ubiquitin
Koeniger, S. L., Merenbloom, S. I., Sundarapandian, S., & Clemmer, D. E. (2006) · Journal of the American Chemical Society · doi:10.1021/ja062137g · Cited by 93
Pierson, N. A., Valentine, S. J., & Clemmer, D. E. (2010) · The Journal of Physical Chemistry B · doi:10.1021/jp102478k · Cited by 89
Knapman, T. W., Morton, V. L., Stonehouse, N. J., Stockley, P. G., & Ashcroft, A. E. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4732 · Cited by 87
A method for direct measurement of ion mobilities using a travelling wave ion guide
Giles, K., Wildgoose, J. L., Langridge, D., & Campuzano, I. D. G. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2009.10.008 · Cited by 84
Self-citationWilliams, J. P., Bugarcic, T., Habtemariam, A., Giles, K., Campuzano, I. D. G., Rodger, P. M., & Sadler, P. J. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.02.016 · Cited by 79
Self-citationProbing hemoglobin structure by means of traveling-wave ion mobility mass spectrometry
Scarff, C. A., Patel, V. J., Thalassinos, K., et al. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.11.023 · Cited by 75
Dear, G. J., Muñoz, J. A., Beaumont, C., Roberts, A., Kirk, J. M., Williams, J. P., & Campuzano, I. D. G. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4742 · Cited by 73
Self-citationResidual counter ions can stabilise a large protein complex in the gas phase
Freeke, J., Robinson, C. V., & Ruotolo, B. T. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2009.08.001 · Cited by 70
Lorenzen, K., Versluis, C., van Duijn, E., van den Heuvel, R. H. H., & Heck, A. J. R. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2007.06.012 · Cited by 70
Developing liquid chromatography ion mobility mass spectometry techniques
Valentine, S. J., Liu, X., Plasencia, M. D., Hilderbrand, A. E., Kurulugama, R. T., Koeniger, S. L., & Clemmer, D. E. (2005) · Expert Review of Proteomics · doi:10.1586/14789450.2.4.553 · Cited by 65
Eckers, C., Laures, A. M. ‐., Giles, K., Major, H. J., & Pringle, S. D. (2007) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2938 · Cited by 62
Self-citationSegev, E., Wyttenbach, T., Bowers, M. T., & Gerber, R. B. (2008) · Physical Chemistry Chemical Physics · doi:10.1039/b718610j · Cited by 59
Leary, J. A., Schenauer, M. R., Ştefănescu, R., Andaya, A., Ruotolo, B. T., Robinson, C. V., Thalassinos, K., Scrivens, J. H., Sokabe, M., & Hershey, J. W. B. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.05.003 · Cited by 57
Schenauer, M. R., Meissen, J. K., Seo, Y., Ames, J. B., & Leary, J. A. (2009) · Analytical Chemistry · doi:10.1021/ac902186h · Cited by 55
Gao, B., Wyttenbach, T., & Bowers, M. T. (2009) · The Journal of Physical Chemistry B · doi:10.1021/jp903307h · Cited by 50
Gas-phase conformation-specific photofragmentation of proline-containing peptide ions
Kim, T., Valentine, S. J., Clemmer, D. E., & Reilly, J. P. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2010.04.007 · Cited by 33
Cited by
Lanucara, F., Holman, S. W., Gray, C. J., & Eyers, C. E. (2014) · Nature Chemistry · doi:10.1038/nchem.1889 · Cited by 901
Ion Mobility Spectrometry: Fundamental Concepts, Instrumentation, Applications, and the Road Ahead
Dodds, J. N., & Baker, E. S. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02288-2 · Cited by 574
Leung, Y. H., Ng, A. M. C., Xu, X., Shen, Z., Gethings, L. A., Wong, M. T., Chan, C. M. N., Guo, M. Y., Ng, Y. H., Djurišić, A. B., et al. (2014) · Small · doi:10.1002/smll.201302434 · Cited by 566
A Cyclic Ion Mobility-Mass Spectrometry System
Giles, K., Ujma, J., Wildgoose, J., Pringle, S., Richardson, K., Langridge, D., & Green, M. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01838 · Cited by 510
Self-citationRecommendations for reporting ion mobility Mass Spectrometry measurements
Gabelica, V., Shvartsburg, A. A., Afonso, C., Barran, P., Benesch, J. L. P., Bleiholder, C., Bowers, M. T., Bilbao, A., Bush, M. F., Campbell, J. L., et al. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21585 · Cited by 493
Self-citation
Metadata
- Authors
- Giles, K., Williams, J. P., & Campuzano, I.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2011-05-11
- Volume
- 25
- Issue
- 11
- Pages
- 1559-1566
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2115588498
- Cited by
- 369
- References
- 39
- FWCI
- 15.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.