Haptic interaction in robot‐assisted endoscopic surgery: a sensorized end‐effector
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Conventional endoscopic surgery has some drawbacks that can be addressed by using robots. The robotic systems used for surgery are still in their infancy. A major deficiency is the lack of haptic feedback to the surgeon. In this paper, the benefits of haptic feedback in robot‐assisted surgery are discussed. A novel robotic end‐effector is then described that meets the requirements of endoscopic surgery and is sensorized for force/ torque feedback. The endoscopic end‐effector is capable of non‐invasively measuring its interaction with tissue in all the degrees of freedom available during endoscopic manipulation. It is also capable of remotely actuating a tip and measuring its interaction with the environment without using any sensors on the jaws. The sensorized end‐effector can be used as the last arm of a surgical robot to incorporate haptic feedback and/or to evaluate skills and learning curves of residents and surgeons in endoscopic surgery. Copyright © 2005 Robotic Publications Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Information capacity of discrete motor responses.
Fitts, P. M., & Peterson, J. R. (1964) · Journal of Experimental Psychology · doi:10.1037/h0045689 · Cited by 1,534 · cited 1×
“According to Fitt’s law ( 19 ), the movement time has”
BackgroundHaptic guidance: experimental evaluation of a haptic training method for a perceptual motor skill
Feygin, D., Keehner, M., & Tendick, R. (2003) · Proceedings 10th Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems. HAPTICS 2002 · doi:10.1109/haptic.2002.998939 · Cited by 394
Research works printed but not linked: 37
- 10.1007/s00464-001-8283-7 · DOI · Paper page
- 10.1089/lap.2000.10.231 · DOI
- 10.1007/PL00009635 · doi:10.1007/pl00009635
- 10.1080/136457001753337320 · doi:10.1080/136457001753337320
- Tendick F, 1996, Computer‐integrated surgery: technology and clinical applications, 567
- 10.1109/TRA.2003.817058 · DOI · Paper page
- 10.1109/TRA.2003.817071 · DOI · Paper page
- 10.1146/annurev.bioeng.1.1.211 · DOI · Paper page
- Lueth T, 1999, Neuronavigation — neurosurgical and computer scientific aspects
- 10.1016/S0022-5347(01)66715-6 · DOI
- 10.1016/S0002-9610(99)00055-0 · DOI
- 10.1109/TRA.2003.817093 · DOI
- 10.1109/3516.662866 · DOI
- 10.1109/TRA.2003.817214 · doi:10.1109/tra.2003.817214
- ShimogaKB.A survey of perceptual feedback issues in dextrous telemanipulation: Part I. Finger force feedback. In Proceedings of the IEEE Virtual Reality Annual International Symposium;1993; Seattle WA.
- Burdea GC, 1996, Force and touch feedback for virtual reality
- HannafordB WoodL.Performance evaluation of a 6 axis high fidelity generalized force reflecting teleoperator. In Proceedings of JPL/NASA Conference on Space Telerobotics;1989; Pasadena CA.
- MasonAH WaljiMA LeeEJ MacKenzieCL.Reaching movements to augmented and graphic objects in virtual environments. In Proceedings of the SIGCHI Conference on Human Factors in Computing Systems;2001; Seattle WA. · DOI
- Gupta R, 1997, Experiments using multimodal virtual environments in design for assembly analysis, Presence: teleoperators & virtual environments, 6, 318, 10.1162/pres.1997.6.3.318 · doi:10.1162/pres.1997.6.3.318
- 10.1162/105474698565721 · DOI
- Malpass L, 1963, Handbook of Mental Deficiency
- WagnerCR StylopoulosN HoweR.Force feedback in surgery: analysis of blunt dissection. In Proceedings of the 10th Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems;2002; Orlando FL.
- 10.1162/105474603321640950 · DOI
- GerovichevO MarayongP OkamuraAM.The effect of visual and haptic feedback on manual and teleoperated needle insertion. In:DohiT KikinisR editors. Proceedings of the Fifth International Conference on Medical Image Computing and Computer Assisted Intervention — Lecture Notes in Computer Science (Vol. 2488);2002 p.147–54. · doi:10.1007/3-540-45786-0_19
- 10.1016/S0090-4295(01)01423-6 · DOI · Paper page
- 10.1007/s004640080154 · DOI
- Tendick F, 1993, Sensing and manipulation problems in endoscopic surgery: experiment, analysis and observation, Presence: teleoperators & virtual environments, 2, 66, 10.1162/pres.1993.2.1.66 · DOI · Paper page
- 10.1007/s004640000230 · DOI
- 10.1007/s004649900920 · DOI
- ArsenaultR WareC.Eye‐hand co‐ordination with force feedback. In Proceedings of the SIGCHI Conference on Human Factors in Computing Systems;2000; The Hague The Netherlands. · DOI
- 10.1080/13645700310023069 · doi:10.1080/13645700310023069
- TavakoliM PatelRV MoallemM.Design issues in a haptics‐based master‐slave system for minimally invasive surgery. In Proceedings of the IEEE International Conference on Robotics and Automation;2004; New Orleans LA. p.371–6. · doi:10.1109/robot.2004.1307178
- ShermanA CavusogluMC TendickF.Comparison of teleoperator control architectures for palpation task. In Proceedings of the ASME Dynamic Systems and Control Division International Mechanical Engineering Congress and Exposition (IMECE);2000; Orlando FL. p.1261–8. · doi:10.1115/imece2000-2441
- LazeromsM.Force reflection for telemanipulation applied to minimally invasive surgery [dissertation]. Holland: Delft University of Technology;1999.
- 10.1109/TRA.2003.817526 · DOI · Paper page
- 10.1109/10.790498 · DOI · Paper page
- TaylorRM HudsonTC SeegerA WeberH JulianoJ HelserAT.VRPN: A device‐independent network‐transparent VR peripheral system. In Proceedings of ACM Symposium on Virtual Reality Software & Technology;2001; Banff Alberta. · DOI · Paper page
Cited by
van der Meijden, O. A. J., & Schijven, M. P. (2009) · Surgical Endoscopy · doi:10.1007/s00464-008-0298-x · Cited by 541
Haptics in minimally invasive surgery – a review
Westebring – van der Putten, E. P., Goossens, R. H. M., Jakimowicz, J. J., & Dankelman, J. (2008) · Minimally Invasive Therapy & Allied Technologies · doi:10.1080/13645700701820242 · Cited by 328
Medical Robots: Current Systems and Research Directions
Beasley, R. A. (2012) · Journal of Robotics · doi:10.1155/2012/401613 · Cited by 312
Micron: An Actively Stabilized Handheld Tool for Microsurgery
MacLachlan, R. A., Becker, B. C., Tabares, J. C., Podnar, G. W., Lobes, L. A., & Riviere, C. N. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2169634 · Cited by 270
The benefit of force feedback in surgery: Examination of blunt dissection
Wagner, C. R., Stylopoulos, N., Jackson, P. G., & Howe, R. D. (2007) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.16.3.252 · Cited by 169
Metadata
- Authors
- Tavakoli, M., Patel, R. V., & Moallem, M.
- Venue
- The International Journal of Medical Robotics and Computer Assisted Surgery
- Publisher
- Wiley
- Published
- 2005-01
- Volume
- 1
- Issue
- 2
- Pages
- 53-63
- ISSN
- 1478-5951 (ISSN-L)
- 1478-596X
- OpenAlex
- W2120214714
- Cited by
- 132
- References
- 2
- FWCI
- 17.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.