The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
High‐Order Multiple Emulsions Formed in Poly(dimethylsiloxane) Microfluidics
Abstract
Multiple emulsions are formed using poly(dimethylsiloxane) microfluidic devices. The single emulsions (see image, left) are formed using a single drop maker with uniform wettability. The double, triple, quadruple, and quintuple emulsions (right) are formed using linear sequences of drop makers with alternating wettability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Xia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
Formation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302
Monodisperse Double Emulsions Generated from a Microcapillary Device
Utada, A. S., Lorenceau, E., Link, D. R., Kaplan, P. D., Stone, H. A., & Weitz, D. A. (2005) · Science · doi:10.1126/science.1109164 · Cited by 2,248
Self-citationControllable Monodisperse Multiple Emulsions
Chu, L., Utada, A. S., Shah, R. K., Kim, J., & Weitz, D. A. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200701358 · Cited by 747
Self-citationMembrane emulsification — a literature review
Joscelyne, S. M., & Trägårdh, G. (2000) · Journal of Membrane Science · doi:10.1016/s0376-7388(99)00334-8 · Cited by 576
Controlled formulation of monodisperse double emulsions in a multiple-phase microfluidic system
Nisisako, T., Okushima, S., & Torii, T. (2005) · Soft Matter · doi:10.1039/b501972a · Cited by 335
Microfluidic consecutive flow-focusing droplet generators
Seo, M., Paquet, C., Nie, Z., Xu, S., & Kumacheva, E. (2007) · Soft Matter · doi:10.1039/b700687j · Cited by 263
Cournarie, F., Savelli, M.-P., Rosilio, V., Bretez, F., Vauthier, C., Grossiord, J., & Seiller, M. (2004) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2004.03.024 · Cited by 91
Cited by
Emerging Droplet Microfluidics
Shang, L., Cheng, Y., & Zhao, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00848 · Cited by 1,584
Self-Healing Polymers and Composites
Blaiszik, B. J., Kramer, S. L. B., Olugebefola, S. C., Moore, J. S., Sottos, N. R., & White, S. R. (2010) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-070909-104532 · Cited by 1,505
Surfactants in droplet-based microfluidics
Baret, J.-C. (2012) · Lab Chip · doi:10.1039/c1lc20582j · Cited by 649
Formulation, stabilisation and encapsulation of bacteriophage for phage therapy
Malik, D. J., Sokolov, I. J., Vinner, G. K., Mancuso, F., Cinquerrui, S., Vladisavljevic, G. T., Clokie, M. R. J., Garton, N. J., Stapley, A. G. F., & Kirpichnikova, A. (2017) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2017.05.014 · Cited by 594
Gokmen, M. T., & Du Prez, F. E. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.07.006 · Cited by 492
Latest Developments in Micro Total Analysis Systems
Arora, A., Simone, G., Salieb-Beugelaar, G. B., Kim, J. T., & Manz, A. (2010) · Analytical Chemistry · doi:10.1021/ac100969k · Cited by 421
Production of uniform droplets using membrane, microchannel and microfluidic emulsification devices
Vladisavljević, G. T., Kobayashi, I., & Nakajima, M. (2012) · Microfluidics and Nanofluidics · doi:10.1007/s10404-012-0948-0 · Cited by 374
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
Wang, J., Wang, J., & Han, J. (2011) · Small · doi:10.1002/smll.201001913 · Cited by 293
Sheth, T., Seshadri, S., Prileszky, T., & Helgeson, M. E. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0161-9 · Cited by 290
Supraparticles: Functionality from Uniform Structural Motifs
Wintzheimer, S., Granath, T., Oppmann, M., Kister, T., Thai, T., Kraus, T., Vogel, N., & Mandel, K. (2018) · ACS Nano · doi:10.1021/acsnano.8b00873 · Cited by 253
Development and future of droplet microfluidics
Nan, L., Zhang, H., Weitz, D. A., & Shum, H. C. (2024) · Lab on a Chip · doi:10.1039/d3lc00729d · Cited by 253
Self-citation
Metadata
- Authors
- Abate, A. R., & Weitz, D. A.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2009-09-14
- Volume
- 5
- Issue
- 18
- Pages
- 2030-2032
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2159612341
- Cited by
- 311
- References
- 8
- FWCI
- 9.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.