The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Optimized Structural Designs for Stretchable Silicon Integrated Circuits
Open accessAbstract
Materials and design strategies for stretchable silicon integrated circuits that use non‐coplanar mesh layouts and elastomeric substrates are presented. Detailed experimental and theoretical studies reveal many of the key underlying aspects of these systems. The results shpw, as an example, optimized mechanics and materials for circuits that exhibit maximum principal strains less than 0.2% even for applied strains of up to ≈90%. Simple circuits, including complementary metal–oxide–semiconductor inverters and n‐type metal–oxide–semiconductor differential amplifiers, validate these designs. The results suggest practical routes to high‐performance electronics with linear elastic responses to large strain deformations, suitable for diverse applications that are not readily addressed with conventional wafer‐based technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design of metal interconnects for stretchable electronic circuits
Gonzalez, M., Axisa, F., Bulcke, M. V., Brosteaux, D., Vandevelde, B., & Vanfleteren, J. (2008) · Microelectronics Reliability · doi:10.1016/j.microrel.2008.03.025 · Cited by 405
Cited by
Kim, D.-H., Lu, N., Ghaffari, R., Kim, Y.-S., Lee, S. P., Xu, L., Wu, J., Kim, R.-H., Song, J., Liu, Z., et al. (2011) · Nature Materials · doi:10.1038/nmat2971 · Cited by 770
Self-citationFlexible and Stretchable Electronics for Biointegrated Devices
Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150018 · Cited by 749
Self-citationMaterials and Structures toward Soft Electronics
Wang, C., Wang, C., Huang, Z., & Xu, S. (2018) · Advanced Materials · doi:10.1002/adma.201801368 · Cited by 662
Kim, R.-H., Kim, D.-H., Xiao, J., Kim, B. H., Park, S.-I., Panilaitis, B., Ghaffari, R., Yao, J., Li, M., Liu, Z., et al. (2010) · Nature Materials · doi:10.1038/nmat2879 · Cited by 637
Self-citationMaterials and structural designs of stretchable conductors
Matsuhisa, N., Chen, X., Bao, Z., & Someya, T. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00814k · Cited by 566
Energy Harvesters for Wearable and Stretchable Electronics: From Flexibility to Stretchability
Wu, H., Huang, Y., Xu, F., Duan, Y., & Yin, Z. (2016) · Advanced Materials · doi:10.1002/adma.201602251 · Cited by 520
Self-citationKim, S., Wu, J., Carlson, A., Jin, S. H., Kovalsky, A., Glass, P., Liu, Z., Ahmed, N., Elgan, S. L., Chen, W., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1005828107 · Cited by 442
Self-citationReview of Flexible Temperature Sensing Networks for Wearable Physiological Monitoring
Li, Q., Zhang, L., Tao, X., & Ding, X. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201601371 · Cited by 354
Zhang, Y., Wang, S., Li, X., Fan, J. A., Xu, S., Song, Y. M., Choi, K., Yeo, W., Lee, W., Nazaar, S. N., et al. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201302957 · Cited by 354
Self-citationStretchable GaAs Photovoltaics with Designs That Enable High Areal Coverage
Lee, J., Wu, J., Shi, M., Yoon, J., Park, S., Li, M., Liu, Z., Huang, Y., & Rogers, J. A. (2011) · Advanced Materials · doi:10.1002/adma.201003961 · Cited by 318
Self-citationZhang, Y., Xu, S., Fu, H., Lee, J., Su, J., Hwang, K.-C., Rogers, J. A., & Huang, Y. (2013) · Soft Matter · doi:10.1039/c3sm51360b · Cited by 307
Self-citationAn, B. W., Kim, K., Lee, H., Kim, S., Shim, Y., Lee, D., Song, J. Y., & Park, J. (2015) · Advanced Materials · doi:10.1002/adma.201502092 · Cited by 306
Self-citationConducting Polymer Dough for Deformable Electronics
Oh, J. Y., Kim, S., Baik, H., & Jeong, U. (2016) · Advanced Materials · doi:10.1002/adma.201502947 · Cited by 297
Stretchable electronics based on Ag-PDMS composites
Larmagnac, A., Eggenberger, S., Janossy, H., & Vörös, J. (2014) · Scientific Reports · doi:10.1038/srep07254 · Cited by 296
Elastomeric substrates with embedded stiff platforms for stretchable electronics
Romeo, A., Liu, Q., Suo, Z., & Lacour, S. P. (2013) · Applied Physics Letters · doi:10.1063/1.4799653 · Cited by 117
Liquid crystal elastomers as substrates for 3D, robust, implantable electronics
Maeng, J., Rihani, R. T., Javed, M., Rajput, J. S., Kim, H., Bouton, I. G., Criss, T. A., Pancrazio, J. J., Black, B. J., & Ware, T. H. (2020) · Journal of Materials Chemistry B · doi:10.1039/d0tb00471e · Cited by 31
Self-citation
Metadata
- Authors
- Kim, D., Liu, Z., Kim, Y., Wu, J., Song, J., Kim, H., Huang, Y., Hwang, K., Zhang, Y., & Rogers, J. A.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2009-12-14
- Volume
- 5
- Issue
- 24
- Pages
- 2841-2847
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2002815565
- Cited by
- 184
- References
- 1
- FWCI
- 4.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.