The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Dissolving Microneedle Patch for Transdermal Delivery of Human Growth Hormone
Open accessAbstract
The clinical impact of biotechnology has been constrained by the limitations of traditional hypodermic injection of biopharmaceuticals. Microneedle patches have been proposed as a minimally invasive alternative. In this study, the translation of a dissolving microneedle patch designed for simple, painless self‐administration of biopharmacetucials that generates no sharp biohazardous waste is assessed. To study the pharmacokinetics and safety of this approach, human growth hormone (hGH) was encapsulated in 600 μm‐long dissolving microneedles composed of carboxymethylcellulose and trehalose using an aqueous, moderate‐temperature process that maintained complete hGH activity after encapsulation and retained most activity after storage for up to 15 months at room temperature and humidity. After manual insertion into the skin of hairless rats, hGH pharmacokinetics were similar to conventional subcutaneous injection. After patch removal, the microneedles had almost completely dissolved, leaving behind only blunt stubs. The dissolving microneedle patch was well tolerated, causing only slight, transient erythema. This study suggests that a dissolving microneedle patch can deliver hGH and other biopharmaceuticals in a manner suitable for self‐administration without sharp biohazardous waste.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McAllister, D. V., Wang, P. M., Davis, S. P., Park, J.-H., Canatella, P. J., Allen, M. G., & Prausnitz, M. R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2331316100 · Cited by 859
Self-citation
Cited by
Microneedles for drug and vaccine delivery
Kim, Y.-C., Park, J.-H., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,760
Self-citationLarrañeta, E., Lutton, R. E. M., Woolfson, A. D., & Donnelly, R. F. (2016) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2016.03.001 · Cited by 964
Aldawood, F. K., Andar, A., & Desai, S. (2021) · Polymers · doi:10.3390/polym13162815 · Cited by 499
Advances in transdermal insulin delivery
Zhang, Y., Yu, J., Kahkoska, A. R., Wang, J., Buse, J. B., & Gu, Z. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.12.006 · Cited by 325
Metadata
- Authors
- Lee, J. W., Choi, S., Felner, E. I., & Prausnitz, M. R.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2011-01-04
- Volume
- 7
- Issue
- 4
- Pages
- 531-539
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2140666937
- Cited by
- 301
- References
- 1
- FWCI
- 8.80
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dissolving Microneedle Patch for Transdermal Delivery of Human Growth Hormone. https://app.cochat.ai/papers/10.1002/smll.201001091
- The paper
- Lee, J. W., Choi, S., Felner, E. I., & Prausnitz, M. R. (2011). Dissolving Microneedle Patch for Transdermal Delivery of Human Growth Hormone. Small. https://doi.org/10.1002/smll.201001091
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.